{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/31585"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/31585","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Hybrid simulation and its application to the gravity load collapse of reinforced concrete frames","abstract":"The structural testing method called hybrid simulation is implemented at the University of British Columbia. A tutorial is presented to assist the user on how to perform hybrid simulation of structural systems using the finite element software OpenSees, the software framework for hybrid simulation OpenFresco and an event-driven predictor-corrector scheme ensuring continuous testing. Geographically distributed hybrid simulation is introduced and distributed tests performed between the University of British Columbia and the University of California, Berkeley, are described. A hybrid simulation test setup is developed to investigate and validate the application of hybrid simulation to the gravity load collapse of reinforced concrete frames. A shear-critical reinforced concrete column loaded through three dynamic actuators constitutes the physical substructure while a nonlinear ductile reinforced concrete frame makes up the numerical substructure within the OpenSees environment. A nonlinear transformation method is implemented to allow for an accurate application of the three-degree-of-freedom loading on the specimen through the three-actuator test setup, and a specific predictor-corrector algorithm with variable actuator speed is designed to ensure smooth continuous testing despite the use of an implicit iterative integration scheme. Furthermore, a methodology using an iterative predictor-corrector algorithm with mode-switch is developed to enable the use of force control for the actuators in combination with a displacement-based finite element analysis engine. Results from the hybrid tests are compared with a shaking table test of the same structure, and are shown to exhibit the same general behaviour: shear and axial load failure of the shear-critical column followed by gravity load redistribution. However, the inability of the analytical model to capture the residual drifts observed in the shake table tests resulted in an underprediction of the drift demand on the system.","abstract_html":"The structural testing method called hybrid simulation is implemented at the University of British Columbia. A tutorial is presented to assist the user on how to perform hybrid simulation of structural systems using the finite element software OpenSees, the software framework for hybrid simulation OpenFresco and an event-driven predictor-corrector scheme ensuring continuous testing. Geographically distributed hybrid simulation is introduced and distributed tests performed between the University of British Columbia and the University of California, Berkeley, are described. A hybrid simulation test setup is developed to investigate and validate the application of hybrid simulation to the gravity load collapse of reinforced concrete frames. A shear-critical reinforced concrete column loaded through three dynamic actuators constitutes the physical substructure while a nonlinear ductile reinforced concrete frame makes up the numerical substructure within the OpenSees environment. A nonlinear transformation method is implemented to allow for an accurate application of the three-degree-of-freedom loading on the specimen through the three-actuator test setup, and a specific predictor-corrector algorithm with variable actuator speed is designed to ensure smooth continuous testing despite the use of an implicit iterative integration scheme. Furthermore, a methodology using an iterative predictor-corrector algorithm with mode-switch is developed to enable the use of force control for the actuators in combination with a displacement-based finite element analysis engine. Results from the hybrid tests are compared with a shaking table test of the same structure, and are shown to exhibit the same general behaviour: shear and axial load failure of the shear-critical column followed by gravity load redistribution. However, the inability of the analytical model to capture the residual drifts observed in the shake table tests resulted in an underprediction of the drift demand on the system.","abstract_has_math":false,"creators":["Charlet, Arnaud Yves"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-19T14:46:58Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/31585","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/31585","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/31585/1/ubc_2007-0354.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F31585","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Charlet, Arnaud Yves"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/31585","http://circle.library.ubc.ca/bitstream/2429/31585/1/ubc_2007-0354.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The structural testing method called hybrid simulation is implemented at the University of British Columbia. A tutorial is presented to assist the user on how to perform hybrid simulation of structural systems using the finite element software OpenSees, the software framework for hybrid simulation OpenFresco and an event-driven predictor-corrector scheme ensuring continuous testing. Geographically distributed hybrid simulation is introduced and distributed tests performed between the University of British Columbia and the University of California, Berkeley, are described. A hybrid simulation test setup is developed to investigate and validate the application of hybrid simulation to the gravity load collapse of reinforced concrete frames. A shear-critical reinforced concrete column loaded through three dynamic actuators constitutes the physical substructure while a nonlinear ductile reinforced concrete frame makes up the numerical substructure within the OpenSees environment. A nonlinear transformation method is implemented to allow for an accurate application of the three-degree-of-freedom loading on the specimen through the three-actuator test setup, and a specific predictor-corrector algorithm with variable actuator speed is designed to ensure smooth continuous testing despite the use of an implicit iterative integration scheme. Furthermore, a methodology using an iterative predictor-corrector algorithm with mode-switch is developed to enable the use of force control for the actuators in combination with a displacement-based finite element analysis engine. Results from the hybrid tests are compared with a shaking table test of the same structure, and are shown to exhibit the same general behaviour: shear and axial load failure of the shear-critical column followed by gravity load redistribution. However, the inability of the analytical model to capture the residual drifts observed in the shake table tests resulted in an underprediction of the drift demand on the system."]},{"key":"dc:format","label":"Dc Format","values":["19296082","application/pdf"]},{"key":"dc:title","label":"Title","values":["Hybrid simulation and its application to the gravity load collapse of reinforced concrete frames"]}]}],"canonical_facts":{"dc:creator":["Charlet, Arnaud Yves"],"dc:date":["2007"],"dc:description":["The structural testing method called hybrid simulation is implemented at the University of British Columbia. A tutorial is presented to assist the user on how to perform hybrid simulation of structural systems using the finite element software OpenSees, the software framework for hybrid simulation OpenFresco and an event-driven predictor-corrector scheme ensuring continuous testing. Geographically distributed hybrid simulation is introduced and distributed tests performed between the University of British Columbia and the University of California, Berkeley, are described. A hybrid simulation test setup is developed to investigate and validate the application of hybrid simulation to the gravity load collapse of reinforced concrete frames. A shear-critical reinforced concrete column loaded through three dynamic actuators constitutes the physical substructure while a nonlinear ductile reinforced concrete frame makes up the numerical substructure within the OpenSees environment. A nonlinear transformation method is implemented to allow for an accurate application of the three-degree-of-freedom loading on the specimen through the three-actuator test setup, and a specific predictor-corrector algorithm with variable actuator speed is designed to ensure smooth continuous testing despite the use of an implicit iterative integration scheme. Furthermore, a methodology using an iterative predictor-corrector algorithm with mode-switch is developed to enable the use of force control for the actuators in combination with a displacement-based finite element analysis engine. Results from the hybrid tests are compared with a shaking table test of the same structure, and are shown to exhibit the same general behaviour: shear and axial load failure of the shear-critical column followed by gravity load redistribution. However, the inability of the analytical model to capture the residual drifts observed in the shake table tests resulted in an underprediction of the drift demand on the system."],"dc:format":["19296082","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/31585","http://circle.library.ubc.ca/bitstream/2429/31585/1/ubc_2007-0354.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Hybrid simulation and its application to the gravity load collapse of reinforced concrete frames"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:46:58Z"}