{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/31661"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/31661","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Performance of shear stud clusters for precast concrete bridge deck panels","abstract":"The current edition of the Canadian Highway Bridge Design Code (CHBDC), CAN/CSA-S6-00 provides limited guidance for the design of composite bridges with precast concrete deck panels and steel girders. The shear connection is critical in determining the overall performance of the composite superstructure and is commonly achieved with a grout blockout in a precast concrete deck panel, which accepts a cluster of tightly spaced steel shear studs. No specific equations are found in the CHBDC for the design of shear studs used in this system. Furthermore, the current longitudinal spacing limitation of 600 mm for shear studs in the CHBDC is not conducive to the construction of precast concrete decks where an increased spacing of the stud cluster is desirable. An experimental testing regime was completed using push-test specimens constructed with precast concrete panels connected to steel flanges with steel studs within a circular grout pocket. Specimens were tested to failure to determine the ultimate capacity of a stud cluster and to investigate the reduction in ultimate strength after exposure to a number of loading cycles. A 36 m simple span composite superstructure was designed to the CHBDC. A parametric study was conducted on the spacing of stud clusters to investigate the serviceability limit state of the composite superstructure using data captured from the push test specimens. Experiments show that clustered shear studs embedded in high strength grout for construction using precast deck panels meet CHBDC strength requirements and that exceeding the code maximum stud spacing of 600 mm by a factor of two will not result in excessive displacements.","abstract_html":"The current edition of the Canadian Highway Bridge Design Code (CHBDC), CAN/CSA-S6-00 provides limited guidance for the design of composite bridges with precast concrete deck panels and steel girders. The shear connection is critical in determining the overall performance of the composite superstructure and is commonly achieved with a grout blockout in a precast concrete deck panel, which accepts a cluster of tightly spaced steel shear studs. No specific equations are found in the CHBDC for the design of shear studs used in this system. Furthermore, the current longitudinal spacing limitation of 600 mm for shear studs in the CHBDC is not conducive to the construction of precast concrete decks where an increased spacing of the stud cluster is desirable. An experimental testing regime was completed using push-test specimens constructed with precast concrete panels connected to steel flanges with steel studs within a circular grout pocket. Specimens were tested to failure to determine the ultimate capacity of a stud cluster and to investigate the reduction in ultimate strength after exposure to a number of loading cycles. A 36 m simple span composite superstructure was designed to the CHBDC. A parametric study was conducted on the spacing of stud clusters to investigate the serviceability limit state of the composite superstructure using data captured from the push test specimens. Experiments show that clustered shear studs embedded in high strength grout for construction using precast deck panels meet CHBDC strength requirements and that exceeding the code maximum stud spacing of 600 mm by a factor of two will not result in excessive displacements.","abstract_has_math":false,"creators":["Larose, Kent Evan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-27T06:04:51Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2429/31661","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/2429/31661","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aubc%3Aoai%3Acircle.library.ubc.ca%3A2429%2F31661","prefix":"oai_dc"},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F31661","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Larose, Kent Evan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/31661"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The current edition of the Canadian Highway Bridge Design Code (CHBDC), CAN/CSA-S6-00 provides limited guidance for the design of composite bridges with precast concrete deck panels and steel girders. The shear connection is critical in determining the overall performance of the composite superstructure and is commonly achieved with a grout blockout in a precast concrete deck panel, which accepts a cluster of tightly spaced steel shear studs. No specific equations are found in the CHBDC for the design of shear studs used in this system. Furthermore, the current longitudinal spacing limitation of 600 mm for shear studs in the CHBDC is not conducive to the construction of precast concrete decks where an increased spacing of the stud cluster is desirable. An experimental testing regime was completed using push-test specimens constructed with precast concrete panels connected to steel flanges with steel studs within a circular grout pocket. Specimens were tested to failure to determine the ultimate capacity of a stud cluster and to investigate the reduction in ultimate strength after exposure to a number of loading cycles. A 36 m simple span composite superstructure was designed to the CHBDC. A parametric study was conducted on the spacing of stud clusters to investigate the serviceability limit state of the composite superstructure using data captured from the push test specimens. Experiments show that clustered shear studs embedded in high strength grout for construction using precast deck panels meet CHBDC strength requirements and that exceeding the code maximum stud spacing of 600 mm by a factor of two will not result in excessive displacements."]},{"key":"dc:format","label":"Dc Format","values":["15217623","application/pdf"]},{"key":"dc:title","label":"Title","values":["Performance of shear stud clusters for precast concrete bridge deck panels"]}]}],"canonical_facts":{"dc:creator":["Larose, Kent Evan"],"dc:date":["2006"],"dc:description":["The current edition of the Canadian Highway Bridge Design Code (CHBDC), CAN/CSA-S6-00 provides limited guidance for the design of composite bridges with precast concrete deck panels and steel girders. The shear connection is critical in determining the overall performance of the composite superstructure and is commonly achieved with a grout blockout in a precast concrete deck panel, which accepts a cluster of tightly spaced steel shear studs. No specific equations are found in the CHBDC for the design of shear studs used in this system. Furthermore, the current longitudinal spacing limitation of 600 mm for shear studs in the CHBDC is not conducive to the construction of precast concrete decks where an increased spacing of the stud cluster is desirable. An experimental testing regime was completed using push-test specimens constructed with precast concrete panels connected to steel flanges with steel studs within a circular grout pocket. Specimens were tested to failure to determine the ultimate capacity of a stud cluster and to investigate the reduction in ultimate strength after exposure to a number of loading cycles. A 36 m simple span composite superstructure was designed to the CHBDC. A parametric study was conducted on the spacing of stud clusters to investigate the serviceability limit state of the composite superstructure using data captured from the push test specimens. Experiments show that clustered shear studs embedded in high strength grout for construction using precast deck panels meet CHBDC strength requirements and that exceeding the code maximum stud spacing of 600 mm by a factor of two will not result in excessive displacements."],"dc:format":["15217623","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/31661"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Performance of shear stud clusters for precast concrete bridge deck panels"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-27T06:04:51Z"}