{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/32466"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/32466","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Development of a high-concentration hydrogen sensor and a gas sensor test bench","abstract":"Resistive hydrogen gas sensors based on palladium-hydrogen (Pd-H2) interactions were fabricated and tested. This thesis presents expected resistance characteristics for these sensors, and describes their fabrication process. Test results and analysis identified the H2 sensing mechanisms in these sensors. In particular, linearity between sensor resistance and the approximate atomic hydrogen content in the Pd was established, and the estimated proportionality constant obtained is 2.7± 0.9 (a.u.). A low flow rate sensor test bench featuring a line-switching mechanism was designed and built also. A description of the test bench and its operation principles are discussed. Response times obtained from initial tests of the un-optimized system is 16s ± 9s, comparable to the system response time of a commercial gas sensor test station presently available. Recommendations for future work to optimize this test bench are discussed, as are recommendations for future sensor design and development.","abstract_html":"Resistive hydrogen gas sensors based on palladium-hydrogen (Pd-H2) interactions were fabricated and tested. This thesis presents expected resistance characteristics for these sensors, and describes their fabrication process. Test results and analysis identified the H2 sensing mechanisms in these sensors. In particular, linearity between sensor resistance and the approximate atomic hydrogen content in the Pd was established, and the estimated proportionality constant obtained is 2.7± 0.9 (a.u.). A low flow rate sensor test bench featuring a line-switching mechanism was designed and built also. A description of the test bench and its operation principles are discussed. Response times obtained from initial tests of the un-optimized system is 16s ± 9s, comparable to the system response time of a commercial gas sensor test station presently available. Recommendations for future work to optimize this test bench are discussed, as are recommendations for future sensor design and development.","abstract_has_math":false,"creators":["Fan, Lilian Lai Yee"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Engineering Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-19T14:47:26Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/32466","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/32466","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/32466/4/ubc_2007-0090a.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F32466","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fan, Lilian Lai Yee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/32466","http://circle.library.ubc.ca/bitstream/2429/32466/4/ubc_2007-0090a.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Resistive hydrogen gas sensors based on palladium-hydrogen (Pd-H2) interactions were fabricated and tested. This thesis presents expected resistance characteristics for these sensors, and describes their fabrication process. Test results and analysis identified the H2 sensing mechanisms in these sensors. In particular, linearity between sensor resistance and the approximate atomic hydrogen content in the Pd was established, and the estimated proportionality constant obtained is 2.7± 0.9 (a.u.). A low flow rate sensor test bench featuring a line-switching mechanism was designed and built also. A description of the test bench and its operation principles are discussed. Response times obtained from initial tests of the un-optimized system is 16s ± 9s, comparable to the system response time of a commercial gas sensor test station presently available. Recommendations for future work to optimize this test bench are discussed, as are recommendations for future sensor design and development."]},{"key":"dc:format","label":"Dc Format","values":["21523063","application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a high-concentration hydrogen sensor and a gas sensor test bench"]}]}],"canonical_facts":{"dc:creator":["Fan, Lilian Lai Yee"],"dc:date":["2007"],"dc:description":["Resistive hydrogen gas sensors based on palladium-hydrogen (Pd-H2) interactions were fabricated and tested. This thesis presents expected resistance characteristics for these sensors, and describes their fabrication process. Test results and analysis identified the H2 sensing mechanisms in these sensors. In particular, linearity between sensor resistance and the approximate atomic hydrogen content in the Pd was established, and the estimated proportionality constant obtained is 2.7± 0.9 (a.u.). A low flow rate sensor test bench featuring a line-switching mechanism was designed and built also. A description of the test bench and its operation principles are discussed. Response times obtained from initial tests of the un-optimized system is 16s ± 9s, comparable to the system response time of a commercial gas sensor test station presently available. Recommendations for future work to optimize this test bench are discussed, as are recommendations for future sensor design and development."],"dc:format":["21523063","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/32466","http://circle.library.ubc.ca/bitstream/2429/32466/4/ubc_2007-0090a.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Development of a high-concentration hydrogen sensor and a gas sensor test bench"],"dc:type":["Text"],"thesis:degree_discipline":["Engineering Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:47:26Z"}