{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/32624"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/32624","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The effects of polyacrylamide flocculants on sulphide flotation and flotation tailings","abstract":"The relative effectiveness of anionic and nonionic polyacrylamide in enhancing the settling rate of flotation tailings was studied by performing batch settling tests. Anionic polyacrylamide was found to be more effective than nonionic polyacrylamide. A liquid flocculant was found to give lower settling rates than dry flocculants due to a lower polyacrylamide content. The aging of tailings resulted in increased settling rates. Residual polyacrylamide was detected in the supernatant water even at low flocculant addition rates and reached significant concentrations before the optimum addition rate was attained. The effect of polyacrylamide on flotation of a copper-molybdenum ore was investigated in a series of batch flotation tests. Flocculant concentrations up to 10 parts per million did not lower either concentrate grade or recovery. The presence of an oil phase from the liquid flocculant also had no noticeable effect on flotation.","abstract_html":"The relative effectiveness of anionic and nonionic polyacrylamide in enhancing the settling rate of flotation tailings was studied by performing batch settling tests. Anionic polyacrylamide was found to be more effective than nonionic polyacrylamide. A liquid flocculant was found to give lower settling rates than dry flocculants due to a lower polyacrylamide content. The aging of tailings resulted in increased settling rates. Residual polyacrylamide was detected in the supernatant water even at low flocculant addition rates and reached significant concentrations before the optimum addition rate was attained. The effect of polyacrylamide on flotation of a copper-molybdenum ore was investigated in a series of batch flotation tests. Flocculant concentrations up to 10 parts per million did not lower either concentrate grade or recovery. The presence of an oil phase from the liquid flocculant also had no noticeable effect on flotation.","abstract_has_math":false,"creators":["Vreugde, Morris Johannes Aloysius"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mining Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1973,"date_issued":"1973","date_published":"1973","updated_at":"2026-11-19T14:47:34Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/32624","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/32624","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/32624/1/UBC_1973_A7+V74_9.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F32624","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Vreugde, Morris Johannes Aloysius"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1973"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mining Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/32624","http://circle.library.ubc.ca/bitstream/2429/32624/1/UBC_1973_A7+V74_9.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The relative effectiveness of anionic and nonionic polyacrylamide in enhancing the settling rate of flotation tailings was studied by performing batch settling tests. Anionic polyacrylamide was found to be more effective than nonionic polyacrylamide. A liquid flocculant was found to give lower settling rates than dry flocculants due to a lower polyacrylamide content. The aging of tailings resulted in increased settling rates. Residual polyacrylamide was detected in the supernatant water even at low flocculant addition rates and reached significant concentrations before the optimum addition rate was attained. The effect of polyacrylamide on flotation of a copper-molybdenum ore was investigated in a series of batch flotation tests. Flocculant concentrations up to 10 parts per million did not lower either concentrate grade or recovery. The presence of an oil phase from the liquid flocculant also had no noticeable effect on flotation."]},{"key":"dc:format","label":"Dc Format","values":["4477251","application/pdf"]},{"key":"dc:title","label":"Title","values":["The effects of polyacrylamide flocculants on sulphide flotation and flotation tailings"]}]}],"canonical_facts":{"dc:creator":["Vreugde, Morris Johannes Aloysius"],"dc:date":["1973"],"dc:description":["The relative effectiveness of anionic and nonionic polyacrylamide in enhancing the settling rate of flotation tailings was studied by performing batch settling tests. Anionic polyacrylamide was found to be more effective than nonionic polyacrylamide. A liquid flocculant was found to give lower settling rates than dry flocculants due to a lower polyacrylamide content. The aging of tailings resulted in increased settling rates. Residual polyacrylamide was detected in the supernatant water even at low flocculant addition rates and reached significant concentrations before the optimum addition rate was attained. The effect of polyacrylamide on flotation of a copper-molybdenum ore was investigated in a series of batch flotation tests. Flocculant concentrations up to 10 parts per million did not lower either concentrate grade or recovery. The presence of an oil phase from the liquid flocculant also had no noticeable effect on flotation."],"dc:format":["4477251","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/32624","http://circle.library.ubc.ca/bitstream/2429/32624/1/UBC_1973_A7+V74_9.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The effects of polyacrylamide flocculants on sulphide flotation and flotation tailings"],"dc:type":["Text"],"thesis:degree_discipline":["Mining Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:47:34Z"}