{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/33048"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/33048","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Computer-controlled microscope for the automatic classification of white blood cells.","abstract":"A microscope was interfaced to a PDP-9 computer in order to develop techniques suitable for on-line classification of white blood cells. The computer visual-input system is composed of an image dissector optically coupled to a microscope used in a transmitted light mode. The position of the slide under the microscope and the fine focus control are controllable from the computer. A technique of auto-focusing was developed to efficiently focus the microscope under computer control. This algorithm is described in detail, followed by a discussion of the physical factors that affect the performance of this technique. A method of locating or isolating the leukocytes (white blood cells) is described next. A constant, referred to as the \"contrast ratio' is used to extract the threshold for the nuclei of the leukocytes based on the average background intensity. Finally, contour tracing and curvature function extraction are used as a means of testing the system. A specific test is conducted to obtain a comparison of the system's efficiency as compared to that of \"manual\" techniques used by a technician. The system described here is not only suitable for automatic leukocyte classification, but could also be used for many other routine tests requiring the examination of microscopic cells.","abstract_html":"A microscope was interfaced to a PDP-9 computer in order to develop techniques suitable for on-line classification of white blood cells. The computer visual-input system is composed of an image dissector optically coupled to a microscope used in a transmitted light mode. The position of the slide under the microscope and the fine focus control are controllable from the computer. A technique of auto-focusing was developed to efficiently focus the microscope under computer control. This algorithm is described in detail, followed by a discussion of the physical factors that affect the performance of this technique. A method of locating or isolating the leukocytes (white blood cells) is described next. A constant, referred to as the &quot;contrast ratio&#x27; is used to extract the threshold for the nuclei of the leukocytes based on the average background intensity. Finally, contour tracing and curvature function extraction are used as a means of testing the system. A specific test is conducted to obtain a comparison of the system&#x27;s efficiency as compared to that of &quot;manual&quot; techniques used by a technician. The system described here is not only suitable for automatic leukocyte classification, but could also be used for many other routine tests requiring the examination of microscopic cells.","abstract_has_math":false,"creators":["Gabert, Howard Frederick"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1973,"date_issued":"1973","date_published":"1973","updated_at":"2026-11-19T14:47:44Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/33048","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/33048","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/33048/1/UBC_1973_A7+G32_4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F33048","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gabert, Howard Frederick"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1973"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/33048","http://circle.library.ubc.ca/bitstream/2429/33048/1/UBC_1973_A7+G32_4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A microscope was interfaced to a PDP-9 computer in order to develop techniques suitable for on-line classification of white blood cells. The computer visual-input system is composed of an image dissector optically coupled to a microscope used in a transmitted light mode. The position of the slide under the microscope and the fine focus control are controllable from the computer. A technique of auto-focusing was developed to efficiently focus the microscope under computer control. This algorithm is described in detail, followed by a discussion of the physical factors that affect the performance of this technique. A method of locating or isolating the leukocytes (white blood cells) is described next. A constant, referred to as the \"contrast ratio' is used to extract the threshold for the nuclei of the leukocytes based on the average background intensity. Finally, contour tracing and curvature function extraction are used as a means of testing the system. A specific test is conducted to obtain a comparison of the system's efficiency as compared to that of \"manual\" techniques used by a technician. The system described here is not only suitable for automatic leukocyte classification, but could also be used for many other routine tests requiring the examination of microscopic cells."]},{"key":"dc:format","label":"Dc Format","values":["4839456","application/pdf"]},{"key":"dc:title","label":"Title","values":["Computer-controlled microscope for the automatic classification of white blood cells."]}]}],"canonical_facts":{"dc:creator":["Gabert, Howard Frederick"],"dc:date":["1973"],"dc:description":["A microscope was interfaced to a PDP-9 computer in order to develop techniques suitable for on-line classification of white blood cells. The computer visual-input system is composed of an image dissector optically coupled to a microscope used in a transmitted light mode. The position of the slide under the microscope and the fine focus control are controllable from the computer. A technique of auto-focusing was developed to efficiently focus the microscope under computer control. This algorithm is described in detail, followed by a discussion of the physical factors that affect the performance of this technique. A method of locating or isolating the leukocytes (white blood cells) is described next. A constant, referred to as the \"contrast ratio' is used to extract the threshold for the nuclei of the leukocytes based on the average background intensity. Finally, contour tracing and curvature function extraction are used as a means of testing the system. A specific test is conducted to obtain a comparison of the system's efficiency as compared to that of \"manual\" techniques used by a technician. The system described here is not only suitable for automatic leukocyte classification, but could also be used for many other routine tests requiring the examination of microscopic cells."],"dc:format":["4839456","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/33048","http://circle.library.ubc.ca/bitstream/2429/33048/1/UBC_1973_A7+G32_4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Computer-controlled microscope for the automatic classification of white blood cells."],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:47:44Z"}