{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/33337"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/33337","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Ellipsometric studies of electro-optic and ionic conductivity effects in thin oxide films","abstract":"An automated ellipsometer was used to study three topics associated with the anodic oxide films of tantalum and niobium. The electro-optic effect was measured on tantalum and niobium oxides and was found to be quadratic. The change in refractive index upon application of a field occurred in two phases: an instantaneous change followed by a slower change. The effects on Nb₂O₅ were greater than on Ta₂O₅. The effect of ultra violet light on the two oxides was found to cause a change in the refractive index before appreciable photo-induced growth occurred. The results indicated that it was unlikely that the u.v.-induced change in refractive index occurred uniformly throughout the film. The effects of annealing and temperature are discussed in relation to the constant field current transient. The change in the refractive index during the transient was monitored with the ellipsometer.","abstract_html":"An automated ellipsometer was used to study three topics associated with the anodic oxide films of tantalum and niobium. The electro-optic effect was measured on tantalum and niobium oxides and was found to be quadratic. The change in refractive index upon application of a field occurred in two phases: an instantaneous change followed by a slower change. The effects on Nb₂O₅ were greater than on Ta₂O₅. The effect of ultra violet light on the two oxides was found to cause a change in the refractive index before appreciable photo-induced growth occurred. The results indicated that it was unlikely that the u.v.-induced change in refractive index occurred uniformly throughout the film. The effects of annealing and temperature are discussed in relation to the constant field current transient. The change in the refractive index during the transient was monitored with the ellipsometer.","abstract_has_math":false,"creators":["Cornish, William Duncan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1972,"date_issued":"1972","date_published":"1972","updated_at":"2026-11-19T14:47:56Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/33337","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/33337","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/33337/1/UBC_1972_A7+C67.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F33337","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cornish, William Duncan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1972"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/33337","http://circle.library.ubc.ca/bitstream/2429/33337/1/UBC_1972_A7+C67.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An automated ellipsometer was used to study three topics associated with the anodic oxide films of tantalum and niobium. The electro-optic effect was measured on tantalum and niobium oxides and was found to be quadratic. The change in refractive index upon application of a field occurred in two phases: an instantaneous change followed by a slower change. The effects on Nb₂O₅ were greater than on Ta₂O₅. The effect of ultra violet light on the two oxides was found to cause a change in the refractive index before appreciable photo-induced growth occurred. The results indicated that it was unlikely that the u.v.-induced change in refractive index occurred uniformly throughout the film. The effects of annealing and temperature are discussed in relation to the constant field current transient. The change in the refractive index during the transient was monitored with the ellipsometer."]},{"key":"dc:format","label":"Dc Format","values":["3754938","application/pdf"]},{"key":"dc:title","label":"Title","values":["Ellipsometric studies of electro-optic and ionic conductivity effects in thin oxide films"]}]}],"canonical_facts":{"dc:creator":["Cornish, William Duncan"],"dc:date":["1972"],"dc:description":["An automated ellipsometer was used to study three topics associated with the anodic oxide films of tantalum and niobium. The electro-optic effect was measured on tantalum and niobium oxides and was found to be quadratic. The change in refractive index upon application of a field occurred in two phases: an instantaneous change followed by a slower change. The effects on Nb₂O₅ were greater than on Ta₂O₅. The effect of ultra violet light on the two oxides was found to cause a change in the refractive index before appreciable photo-induced growth occurred. The results indicated that it was unlikely that the u.v.-induced change in refractive index occurred uniformly throughout the film. The effects of annealing and temperature are discussed in relation to the constant field current transient. The change in the refractive index during the transient was monitored with the ellipsometer."],"dc:format":["3754938","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/33337","http://circle.library.ubc.ca/bitstream/2429/33337/1/UBC_1972_A7+C67.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Ellipsometric studies of electro-optic and ionic conductivity effects in thin oxide films"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:47:56Z"}