{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/33614"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/33614","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The effect of local motor loads on power system stability.","abstract":"The effect of local motor loads on power system stability is investigated. The power system consists of a synchronous generator supplying a large system through a long transmission line. The loads studied are an induction motor, a synchronous motor, and the combination of the two, although a general case of any number of local induction and synchronous motor leads can be easily formulated. Stability is determined by observing the response of the generator and the motors of the system with a fault at the transmission line. The response is calculated from the mathematical model and is- also observed from tests on a dynamic power system model in the laboratory. It is found from the studies that all the local motor loads improve the stability of a power system.","abstract_html":"The effect of local motor loads on power system stability is investigated. The power system consists of a synchronous generator supplying a large system through a long transmission line. The loads studied are an induction motor, a synchronous motor, and the combination of the two, although a general case of any number of local induction and synchronous motor leads can be easily formulated. Stability is determined by observing the response of the generator and the motors of the system with a fault at the transmission line. The response is calculated from the mathematical model and is- also observed from tests on a dynamic power system model in the laboratory. It is found from the studies that all the local motor loads improve the stability of a power system.","abstract_has_math":false,"creators":["Prior, Bruce George"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1971,"date_issued":"1971","date_published":"1971","updated_at":"2026-11-19T14:48:02Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/33614","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/33614","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/33614/1/UBC_1972_A7+P75.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F33614","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Prior, Bruce George"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1971"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/33614","http://circle.library.ubc.ca/bitstream/2429/33614/1/UBC_1972_A7+P75.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The effect of local motor loads on power system stability is investigated. The power system consists of a synchronous generator supplying a large system through a long transmission line. The loads studied are an induction motor, a synchronous motor, and the combination of the two, although a general case of any number of local induction and synchronous motor leads can be easily formulated. Stability is determined by observing the response of the generator and the motors of the system with a fault at the transmission line. The response is calculated from the mathematical model and is- also observed from tests on a dynamic power system model in the laboratory. It is found from the studies that all the local motor loads improve the stability of a power system."]},{"key":"dc:format","label":"Dc Format","values":["4972378","application/pdf"]},{"key":"dc:title","label":"Title","values":["The effect of local motor loads on power system stability."]}]}],"canonical_facts":{"dc:creator":["Prior, Bruce George"],"dc:date":["1971"],"dc:description":["The effect of local motor loads on power system stability is investigated. The power system consists of a synchronous generator supplying a large system through a long transmission line. The loads studied are an induction motor, a synchronous motor, and the combination of the two, although a general case of any number of local induction and synchronous motor leads can be easily formulated. Stability is determined by observing the response of the generator and the motors of the system with a fault at the transmission line. The response is calculated from the mathematical model and is- also observed from tests on a dynamic power system model in the laboratory. It is found from the studies that all the local motor loads improve the stability of a power system."],"dc:format":["4972378","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/33614","http://circle.library.ubc.ca/bitstream/2429/33614/1/UBC_1972_A7+P75.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The effect of local motor loads on power system stability."],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:02Z"}