{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/33616"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/33616","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A high performance diaphragm shock tube with an imploding detonation driver.","abstract":"The performance of a diaphragm shock tube with an imploding detonation driver is theoretically and experimentally investigated. Strong shock waves are produced by a driver in which a detonation is forced to implode to the apex of a conical channel. In this geometry, the area convergence experienced by the imploding front elevates the driver gas temperature and pressure above the usual Chapman-Jouguet values, thereby increasing the strength of the test shock. Theoretically, the relationship between test shock strength, filling pressure, and area reduction in a conical channel is studied. Experimentally, the importance of the geometric parameters - slant angle, channel width and channel convergence - is investigated. The performance of the conical implosion driver compares well with that of other membrane shock tubes. For instance, for oxy-acetylene detonations, driving into argon of 5 Torr, a Mach number greater than 13 may be reached for a driver to test gas pressure ratio of 100. The same Mach number available from a Chapman-Jouguet detonation driver occurs only above a pressure ratio of 200. For cold hydrogen and constant volume oxy-hydrogen combustion, pressure ratios of 10⁶ and 2 X 10⁴ respectively are required to produce Mach 13. Design criteria for a large area reduction driving facility are also given.","abstract_html":"The performance of a diaphragm shock tube with an imploding detonation driver is theoretically and experimentally investigated. Strong shock waves are produced by a driver in which a detonation is forced to implode to the apex of a conical channel. In this geometry, the area convergence experienced by the imploding front elevates the driver gas temperature and pressure above the usual Chapman-Jouguet values, thereby increasing the strength of the test shock. Theoretically, the relationship between test shock strength, filling pressure, and area reduction in a conical channel is studied. Experimentally, the importance of the geometric parameters - slant angle, channel width and channel convergence - is investigated. The performance of the conical implosion driver compares well with that of other membrane shock tubes. For instance, for oxy-acetylene detonations, driving into argon of 5 Torr, a Mach number greater than 13 may be reached for a driver to test gas pressure ratio of 100. The same Mach number available from a Chapman-Jouguet detonation driver occurs only above a pressure ratio of 200. For cold hydrogen and constant volume oxy-hydrogen combustion, pressure ratios of 10⁶ and 2 X 10⁴ respectively are required to produce Mach 13. Design criteria for a large area reduction driving facility are also given.","abstract_has_math":false,"creators":["Redfern, Paul Joseph"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1971,"date_issued":"1971","date_published":"1971","updated_at":"2026-11-19T14:48:04Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/33616","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/33616","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/33616/1/UBC_1972_A7+R43.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F33616","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Redfern, Paul Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1971"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/33616","http://circle.library.ubc.ca/bitstream/2429/33616/1/UBC_1972_A7+R43.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The performance of a diaphragm shock tube with an imploding detonation driver is theoretically and experimentally investigated. Strong shock waves are produced by a driver in which a detonation is forced to implode to the apex of a conical channel. In this geometry, the area convergence experienced by the imploding front elevates the driver gas temperature and pressure above the usual Chapman-Jouguet values, thereby increasing the strength of the test shock. Theoretically, the relationship between test shock strength, filling pressure, and area reduction in a conical channel is studied. Experimentally, the importance of the geometric parameters - slant angle, channel width and channel convergence - is investigated. The performance of the conical implosion driver compares well with that of other membrane shock tubes. For instance, for oxy-acetylene detonations, driving into argon of 5 Torr, a Mach number greater than 13 may be reached for a driver to test gas pressure ratio of 100. The same Mach number available from a Chapman-Jouguet detonation driver occurs only above a pressure ratio of 200. For cold hydrogen and constant volume oxy-hydrogen combustion, pressure ratios of 10⁶ and 2 X 10⁴ respectively are required to produce Mach 13. Design criteria for a large area reduction driving facility are also given."]},{"key":"dc:format","label":"Dc Format","values":["5729656","application/pdf"]},{"key":"dc:title","label":"Title","values":["A high performance diaphragm shock tube with an imploding detonation driver."]}]}],"canonical_facts":{"dc:creator":["Redfern, Paul Joseph"],"dc:date":["1971"],"dc:description":["The performance of a diaphragm shock tube with an imploding detonation driver is theoretically and experimentally investigated. Strong shock waves are produced by a driver in which a detonation is forced to implode to the apex of a conical channel. In this geometry, the area convergence experienced by the imploding front elevates the driver gas temperature and pressure above the usual Chapman-Jouguet values, thereby increasing the strength of the test shock. Theoretically, the relationship between test shock strength, filling pressure, and area reduction in a conical channel is studied. Experimentally, the importance of the geometric parameters - slant angle, channel width and channel convergence - is investigated. The performance of the conical implosion driver compares well with that of other membrane shock tubes. For instance, for oxy-acetylene detonations, driving into argon of 5 Torr, a Mach number greater than 13 may be reached for a driver to test gas pressure ratio of 100. The same Mach number available from a Chapman-Jouguet detonation driver occurs only above a pressure ratio of 200. For cold hydrogen and constant volume oxy-hydrogen combustion, pressure ratios of 10⁶ and 2 X 10⁴ respectively are required to produce Mach 13. Design criteria for a large area reduction driving facility are also given."],"dc:format":["5729656","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/33616","http://circle.library.ubc.ca/bitstream/2429/33616/1/UBC_1972_A7+R43.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A high performance diaphragm shock tube with an imploding detonation driver."],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:04Z"}