{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/34750"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/34750","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Adiabatic demagnetization apparatus for nuclear orientation","abstract":"A cryostat has been built for cooling specimens to temperatures of the order of a hundredth of a Kelvin by thermal contact with an adiabatically demagnetized paramagnetic salt pill. The apparatus was designed for performing nuclear orientation experiments. This thesis describes the construction of the apparatus and experimental tests studying the nuclear orientation of (60)Co in an iron plate. The paramagnetic salt used was chromium potassium alum in an alum-glycerine slurry. In addition to the chrome alum pill a guard pill of manganous ammonium sulphate was used between the alum pill and the 1K helium bath. The pills were supported and thermally isolated by German silver spacers. A copper heat link was embedded in the alum-glycerine slurry and soldered to the specimen to provide thermal contact. Several heat links were used ranging from a bundle of five thousand copper wires to a copper foil \"concertina\" arrangement. A Ventron niobium-titanium superconducting solenoid which produced fields up to 48 kilogauss was used for the magnetic cooling. A superconducting polarizing solenoid was used to magnetically saturate the polycrystalline iron plate. Anisotropies in the gamma radiation intensity from (60)Co of 7 to 11 per cent corresponding to temperatures of 37 to 45 m K were observed.","abstract_html":"A cryostat has been built for cooling specimens to temperatures of the order of a hundredth of a Kelvin by thermal contact with an adiabatically demagnetized paramagnetic salt pill. The apparatus was designed for performing nuclear orientation experiments. This thesis describes the construction of the apparatus and experimental tests studying the nuclear orientation of (60)Co in an iron plate. The paramagnetic salt used was chromium potassium alum in an alum-glycerine slurry. In addition to the chrome alum pill a guard pill of manganous ammonium sulphate was used between the alum pill and the 1K helium bath. The pills were supported and thermally isolated by German silver spacers. A copper heat link was embedded in the alum-glycerine slurry and soldered to the specimen to provide thermal contact. Several heat links were used ranging from a bundle of five thousand copper wires to a copper foil &quot;concertina&quot; arrangement. A Ventron niobium-titanium superconducting solenoid which produced fields up to 48 kilogauss was used for the magnetic cooling. A superconducting polarizing solenoid was used to magnetically saturate the polycrystalline iron plate. Anisotropies in the gamma radiation intensity from (60)Co of 7 to 11 per cent corresponding to temperatures of 37 to 45 m K were observed.","abstract_has_math":false,"creators":["Gorling, Robert Lloyd Albert"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T14:48:35Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/34750","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/34750","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/34750/1/UBC_1970_A6_7+G67.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F34750","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gorling, Robert Lloyd Albert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/34750","http://circle.library.ubc.ca/bitstream/2429/34750/1/UBC_1970_A6_7+G67.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A cryostat has been built for cooling specimens to temperatures of the order of a hundredth of a Kelvin by thermal contact with an adiabatically demagnetized paramagnetic salt pill. The apparatus was designed for performing nuclear orientation experiments. This thesis describes the construction of the apparatus and experimental tests studying the nuclear orientation of (60)Co in an iron plate. The paramagnetic salt used was chromium potassium alum in an alum-glycerine slurry. In addition to the chrome alum pill a guard pill of manganous ammonium sulphate was used between the alum pill and the 1K helium bath. The pills were supported and thermally isolated by German silver spacers. A copper heat link was embedded in the alum-glycerine slurry and soldered to the specimen to provide thermal contact. Several heat links were used ranging from a bundle of five thousand copper wires to a copper foil \"concertina\" arrangement. A Ventron niobium-titanium superconducting solenoid which produced fields up to 48 kilogauss was used for the magnetic cooling. A superconducting polarizing solenoid was used to magnetically saturate the polycrystalline iron plate. Anisotropies in the gamma radiation intensity from (60)Co of 7 to 11 per cent corresponding to temperatures of 37 to 45 m K were observed."]},{"key":"dc:format","label":"Dc Format","values":["3383241","application/pdf"]},{"key":"dc:title","label":"Title","values":["Adiabatic demagnetization apparatus for nuclear orientation"]}]}],"canonical_facts":{"dc:creator":["Gorling, Robert Lloyd Albert"],"dc:date":["1970"],"dc:description":["A cryostat has been built for cooling specimens to temperatures of the order of a hundredth of a Kelvin by thermal contact with an adiabatically demagnetized paramagnetic salt pill. The apparatus was designed for performing nuclear orientation experiments. This thesis describes the construction of the apparatus and experimental tests studying the nuclear orientation of (60)Co in an iron plate. The paramagnetic salt used was chromium potassium alum in an alum-glycerine slurry. In addition to the chrome alum pill a guard pill of manganous ammonium sulphate was used between the alum pill and the 1K helium bath. The pills were supported and thermally isolated by German silver spacers. A copper heat link was embedded in the alum-glycerine slurry and soldered to the specimen to provide thermal contact. Several heat links were used ranging from a bundle of five thousand copper wires to a copper foil \"concertina\" arrangement. A Ventron niobium-titanium superconducting solenoid which produced fields up to 48 kilogauss was used for the magnetic cooling. A superconducting polarizing solenoid was used to magnetically saturate the polycrystalline iron plate. Anisotropies in the gamma radiation intensity from (60)Co of 7 to 11 per cent corresponding to temperatures of 37 to 45 m K were observed."],"dc:format":["3383241","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/34750","http://circle.library.ubc.ca/bitstream/2429/34750/1/UBC_1970_A6_7+G67.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Adiabatic demagnetization apparatus for nuclear orientation"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:35Z"}