{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/34857"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/34857","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A positron spectrometer","abstract":"The existing intermediate image nuclear spectrometer has been modified to count either positrons or negatrons by the addition of a helical baffle. Design considerations of the helical baffle and source requirements for the present investigation have been discussed. An investigation of the positron spectrum of ¹⁵²Eu has been completed. Kurie-plot analysis of the data has confirmed the presence of two primary positron groups with end point energies 713.5 ± 2KeV and 471 ± 5KeV, and intensities (1.0 ± 0.1) x 10⁻⁴ per decay and (0.6 ± 0.2) x 10⁻⁴ per decay respectively. It has been possible to assign error limits to these intensities for the first time. The presence of an internal pair formation positron distribution has also been confirmed. The intensity of the pair formation positrons was deduced from the data for the first time as (0.4 ± 0.05) x 10⁻⁴ per decay, in good agreement with theoretical predictions. The results are in good agreement with previous investigations, excepting the intensity of the 713.5KeV primary positron group. The disparity may be caused by effects due to source and backing thickness in previous work.","abstract_html":"The existing intermediate image nuclear spectrometer has been modified to count either positrons or negatrons by the addition of a helical baffle. Design considerations of the helical baffle and source requirements for the present investigation have been discussed. An investigation of the positron spectrum of ¹⁵²Eu has been completed. Kurie-plot analysis of the data has confirmed the presence of two primary positron groups with end point energies 713.5 ± 2KeV and 471 ± 5KeV, and intensities (1.0 ± 0.1) x 10⁻⁴ per decay and (0.6 ± 0.2) x 10⁻⁴ per decay respectively. It has been possible to assign error limits to these intensities for the first time. The presence of an internal pair formation positron distribution has also been confirmed. The intensity of the pair formation positrons was deduced from the data for the first time as (0.4 ± 0.05) x 10⁻⁴ per decay, in good agreement with theoretical predictions. The results are in good agreement with previous investigations, excepting the intensity of the 713.5KeV primary positron group. The disparity may be caused by effects due to source and backing thickness in previous work.","abstract_has_math":false,"creators":["Brown, Charles Grant"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T14:48:37Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/34857","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/34857","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/34857/1/UBC_1970_A7+B76.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F34857","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Brown, Charles Grant"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/34857","http://circle.library.ubc.ca/bitstream/2429/34857/1/UBC_1970_A7+B76.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The existing intermediate image nuclear spectrometer has been modified to count either positrons or negatrons by the addition of a helical baffle. Design considerations of the helical baffle and source requirements for the present investigation have been discussed. An investigation of the positron spectrum of ¹⁵²Eu has been completed. Kurie-plot analysis of the data has confirmed the presence of two primary positron groups with end point energies 713.5 ± 2KeV and 471 ± 5KeV, and intensities (1.0 ± 0.1) x 10⁻⁴ per decay and (0.6 ± 0.2) x 10⁻⁴ per decay respectively. It has been possible to assign error limits to these intensities for the first time. The presence of an internal pair formation positron distribution has also been confirmed. The intensity of the pair formation positrons was deduced from the data for the first time as (0.4 ± 0.05) x 10⁻⁴ per decay, in good agreement with theoretical predictions. The results are in good agreement with previous investigations, excepting the intensity of the 713.5KeV primary positron group. The disparity may be caused by effects due to source and backing thickness in previous work."]},{"key":"dc:format","label":"Dc Format","values":["3610128","application/pdf"]},{"key":"dc:title","label":"Title","values":["A positron spectrometer"]}]}],"canonical_facts":{"dc:creator":["Brown, Charles Grant"],"dc:date":["1970"],"dc:description":["The existing intermediate image nuclear spectrometer has been modified to count either positrons or negatrons by the addition of a helical baffle. Design considerations of the helical baffle and source requirements for the present investigation have been discussed. An investigation of the positron spectrum of ¹⁵²Eu has been completed. Kurie-plot analysis of the data has confirmed the presence of two primary positron groups with end point energies 713.5 ± 2KeV and 471 ± 5KeV, and intensities (1.0 ± 0.1) x 10⁻⁴ per decay and (0.6 ± 0.2) x 10⁻⁴ per decay respectively. It has been possible to assign error limits to these intensities for the first time. The presence of an internal pair formation positron distribution has also been confirmed. The intensity of the pair formation positrons was deduced from the data for the first time as (0.4 ± 0.05) x 10⁻⁴ per decay, in good agreement with theoretical predictions. The results are in good agreement with previous investigations, excepting the intensity of the 713.5KeV primary positron group. The disparity may be caused by effects due to source and backing thickness in previous work."],"dc:format":["3610128","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/34857","http://circle.library.ubc.ca/bitstream/2429/34857/1/UBC_1970_A7+B76.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A positron spectrometer"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:37Z"}