{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/35046"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/35046","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Atomic beam polarized 3He+ ion source","abstract":"A beam of polarized ³He⁺ ions has been produced using atomic beam method techniques. This method has the attraction of being capable of producing an ion beam with polarizations up to 100%. The polarization of ³He beams presently produced by optical pumping techniques is of the order of 5%. The apparatus is composed of three main sections, the atomic beam source consisting of a supersonic nozzle cooled to liquid helium temperatures to produce a low velocity atomic beam, the tapered hexapole magnet to spatially separate the particles in the two magnetic spin substates, and the electron bombardment ionizer to produce ³He⁺ ions from the neutral ³He atomic beam. The low velocity beam is required because the nuclear magnetic moment of ³He is of the order of 1000 times smaller than the electronic magnetic moment used to separate beams in conventional Stern-Gerlach magnets and to achieve a high ionization efficiency. The measured intensity of the beam produced by the atomic beam source cooled to liquid helium temperature was 1 x 10¹⁸ atoms/sr-sec, the most probable velocity was 310 m/sec, and the velocity full width at half maximum was 50 m/sec. The beam flux through the ionizer increases by a factor of 1.3 when the hexapole field is turned on, in good agreement with the theoretically expected increase. This increase corresponds to a polarization of 65% of the atomic beam. A 12nA³He⁺ ion beam was obtained corresponding to an ionization efficiency of approximately 0.15%.","abstract_html":"A beam of polarized ³He⁺ ions has been produced using atomic beam method techniques. This method has the attraction of being capable of producing an ion beam with polarizations up to 100%. The polarization of ³He beams presently produced by optical pumping techniques is of the order of 5%. The apparatus is composed of three main sections, the atomic beam source consisting of a supersonic nozzle cooled to liquid helium temperatures to produce a low velocity atomic beam, the tapered hexapole magnet to spatially separate the particles in the two magnetic spin substates, and the electron bombardment ionizer to produce ³He⁺ ions from the neutral ³He atomic beam. The low velocity beam is required because the nuclear magnetic moment of ³He is of the order of 1000 times smaller than the electronic magnetic moment used to separate beams in conventional Stern-Gerlach magnets and to achieve a high ionization efficiency. The measured intensity of the beam produced by the atomic beam source cooled to liquid helium temperature was 1 x 10¹⁸ atoms/sr-sec, the most probable velocity was 310 m/sec, and the velocity full width at half maximum was 50 m/sec. The beam flux through the ionizer increases by a factor of 1.3 when the hexapole field is turned on, in good agreement with the theoretically expected increase. This increase corresponds to a polarization of 65% of the atomic beam. A 12nA³He⁺ ion beam was obtained corresponding to an ionization efficiency of approximately 0.15%.","abstract_has_math":false,"creators":["Vyse, Robert Norman"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T14:48:38Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/35046","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/35046","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/35046/1/UBC_1970_A1+V98.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F35046","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Vyse, Robert Norman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/35046","http://circle.library.ubc.ca/bitstream/2429/35046/1/UBC_1970_A1+V98.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A beam of polarized ³He⁺ ions has been produced using atomic beam method techniques. This method has the attraction of being capable of producing an ion beam with polarizations up to 100%. The polarization of ³He beams presently produced by optical pumping techniques is of the order of 5%. The apparatus is composed of three main sections, the atomic beam source consisting of a supersonic nozzle cooled to liquid helium temperatures to produce a low velocity atomic beam, the tapered hexapole magnet to spatially separate the particles in the two magnetic spin substates, and the electron bombardment ionizer to produce ³He⁺ ions from the neutral ³He atomic beam. The low velocity beam is required because the nuclear magnetic moment of ³He is of the order of 1000 times smaller than the electronic magnetic moment used to separate beams in conventional Stern-Gerlach magnets and to achieve a high ionization efficiency. The measured intensity of the beam produced by the atomic beam source cooled to liquid helium temperature was 1 x 10¹⁸ atoms/sr-sec, the most probable velocity was 310 m/sec, and the velocity full width at half maximum was 50 m/sec. The beam flux through the ionizer increases by a factor of 1.3 when the hexapole field is turned on, in good agreement with the theoretically expected increase. This increase corresponds to a polarization of 65% of the atomic beam. A 12nA³He⁺ ion beam was obtained corresponding to an ionization efficiency of approximately 0.15%."]},{"key":"dc:format","label":"Dc Format","values":["8004105","application/pdf"]},{"key":"dc:title","label":"Title","values":["Atomic beam polarized 3He+ ion source"]}]}],"canonical_facts":{"dc:creator":["Vyse, Robert Norman"],"dc:date":["1970"],"dc:description":["A beam of polarized ³He⁺ ions has been produced using atomic beam method techniques. This method has the attraction of being capable of producing an ion beam with polarizations up to 100%. The polarization of ³He beams presently produced by optical pumping techniques is of the order of 5%. The apparatus is composed of three main sections, the atomic beam source consisting of a supersonic nozzle cooled to liquid helium temperatures to produce a low velocity atomic beam, the tapered hexapole magnet to spatially separate the particles in the two magnetic spin substates, and the electron bombardment ionizer to produce ³He⁺ ions from the neutral ³He atomic beam. The low velocity beam is required because the nuclear magnetic moment of ³He is of the order of 1000 times smaller than the electronic magnetic moment used to separate beams in conventional Stern-Gerlach magnets and to achieve a high ionization efficiency. The measured intensity of the beam produced by the atomic beam source cooled to liquid helium temperature was 1 x 10¹⁸ atoms/sr-sec, the most probable velocity was 310 m/sec, and the velocity full width at half maximum was 50 m/sec. The beam flux through the ionizer increases by a factor of 1.3 when the hexapole field is turned on, in good agreement with the theoretically expected increase. This increase corresponds to a polarization of 65% of the atomic beam. A 12nA³He⁺ ion beam was obtained corresponding to an ionization efficiency of approximately 0.15%."],"dc:format":["8004105","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/35046","http://circle.library.ubc.ca/bitstream/2429/35046/1/UBC_1970_A1+V98.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Atomic beam polarized 3He+ ion source"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:38Z"}