{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/35094"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/35094","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Fourier spectroscopy in the far infrared","abstract":"An infrared Fourier spectrophotometer has \"been set up in the solid state laboratory of the University of British Columbia. A cryostat has been built and adapted to the spectrometer. A computer program to analyze the data and plot the spectrum has been written. As a demonstration of the system's capability, the transmission spectrum from 40 cmˉ¹ to 330 cmˉ¹ of boron doped silicon was obtained for the sample at liquid helium temperature. This spectrum was compared to earlier work done by Colbow in the region 240 cmˉ¹ to 330 cmˉ¹. A spectrum of boron and indium doped silicon was Investigated in the hope of finding Bˉ and In⁺ ionized centres. These were not found at the impurity concentrations and temperatures used. A transmission spectrum of intrinsic silicon at liquid helium temperature was obtained for the region 40 cmˉ¹ to 330 cmˉ¹ A comparison of the above spectra suggests that the low energy tail of the boron doped and boron and indium doped samples is due to a frequency dependent value of reflectivity as Is seen from the spectrum for intrinsic silicon.","abstract_html":"An infrared Fourier spectrophotometer has &quot;been set up in the solid state laboratory of the University of British Columbia. A cryostat has been built and adapted to the spectrometer. A computer program to analyze the data and plot the spectrum has been written. As a demonstration of the system&#x27;s capability, the transmission spectrum from 40 cmˉ¹ to 330 cmˉ¹ of boron doped silicon was obtained for the sample at liquid helium temperature. This spectrum was compared to earlier work done by Colbow in the region 240 cmˉ¹ to 330 cmˉ¹. A spectrum of boron and indium doped silicon was Investigated in the hope of finding Bˉ and In⁺ ionized centres. These were not found at the impurity concentrations and temperatures used. A transmission spectrum of intrinsic silicon at liquid helium temperature was obtained for the region 40 cmˉ¹ to 330 cmˉ¹ A comparison of the above spectra suggests that the low energy tail of the boron doped and boron and indium doped samples is due to a frequency dependent value of reflectivity as Is seen from the spectrum for intrinsic silicon.","abstract_has_math":false,"creators":["Strohmaier, Ronald Murray"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T14:48:38Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/35094","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/35094","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/35094/1/UBC_1970_A6_7+S77.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F35094","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Strohmaier, Ronald Murray"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/35094","http://circle.library.ubc.ca/bitstream/2429/35094/1/UBC_1970_A6_7+S77.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An infrared Fourier spectrophotometer has \"been set up in the solid state laboratory of the University of British Columbia. A cryostat has been built and adapted to the spectrometer. A computer program to analyze the data and plot the spectrum has been written. As a demonstration of the system's capability, the transmission spectrum from 40 cmˉ¹ to 330 cmˉ¹ of boron doped silicon was obtained for the sample at liquid helium temperature. This spectrum was compared to earlier work done by Colbow in the region 240 cmˉ¹ to 330 cmˉ¹. A spectrum of boron and indium doped silicon was Investigated in the hope of finding Bˉ and In⁺ ionized centres. These were not found at the impurity concentrations and temperatures used. A transmission spectrum of intrinsic silicon at liquid helium temperature was obtained for the region 40 cmˉ¹ to 330 cmˉ¹ A comparison of the above spectra suggests that the low energy tail of the boron doped and boron and indium doped samples is due to a frequency dependent value of reflectivity as Is seen from the spectrum for intrinsic silicon."]},{"key":"dc:format","label":"Dc Format","values":["5209166","application/pdf"]},{"key":"dc:title","label":"Title","values":["Fourier spectroscopy in the far infrared"]}]}],"canonical_facts":{"dc:creator":["Strohmaier, Ronald Murray"],"dc:date":["1970"],"dc:description":["An infrared Fourier spectrophotometer has \"been set up in the solid state laboratory of the University of British Columbia. A cryostat has been built and adapted to the spectrometer. A computer program to analyze the data and plot the spectrum has been written. As a demonstration of the system's capability, the transmission spectrum from 40 cmˉ¹ to 330 cmˉ¹ of boron doped silicon was obtained for the sample at liquid helium temperature. This spectrum was compared to earlier work done by Colbow in the region 240 cmˉ¹ to 330 cmˉ¹. A spectrum of boron and indium doped silicon was Investigated in the hope of finding Bˉ and In⁺ ionized centres. These were not found at the impurity concentrations and temperatures used. A transmission spectrum of intrinsic silicon at liquid helium temperature was obtained for the region 40 cmˉ¹ to 330 cmˉ¹ A comparison of the above spectra suggests that the low energy tail of the boron doped and boron and indium doped samples is due to a frequency dependent value of reflectivity as Is seen from the spectrum for intrinsic silicon."],"dc:format":["5209166","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/35094","http://circle.library.ubc.ca/bitstream/2429/35094/1/UBC_1970_A6_7+S77.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Fourier spectroscopy in the far infrared"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:48:38Z"}