{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/36076"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/36076","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A portable physiological recording system","abstract":"Equipment was designed and constructed to monitor automatically and unobtrusively up to twelve physiological variables on a human subject engaged in a prolonged field exercise. Inputs from transducers are sampled in turn, and are encoded into 7-digit PCM. They are then recorded on a small tape-recorder worn by the subject. All equipment is battery-operated, but the recorder and digital circuitry is energized for only 1/2 second every 30 seconds. This, permits recording for over 24 hours without interruptions for a change of battery or tape cassette. A decoder and de-commutator were built so that the tapes can be played back later in the laboratory. Selected parameters can be viewed on an oscilloscope or plotted on a chart-recorder. Overall accuracy of the system is 1%. Two types of transducers have been developed: one measures the heart rate and the other the skin temperature. Other transducers remain to be developed. Component circuits were tested at varying environmental temperatures, and a prototype of the whole system was tested on an arctic exercise.","abstract_html":"Equipment was designed and constructed to monitor automatically and unobtrusively up to twelve physiological variables on a human subject engaged in a prolonged field exercise. Inputs from transducers are sampled in turn, and are encoded into 7-digit PCM. They are then recorded on a small tape-recorder worn by the subject. All equipment is battery-operated, but the recorder and digital circuitry is energized for only 1/2 second every 30 seconds. This, permits recording for over 24 hours without interruptions for a change of battery or tape cassette. A decoder and de-commutator were built so that the tapes can be played back later in the laboratory. Selected parameters can be viewed on an oscilloscope or plotted on a chart-recorder. Overall accuracy of the system is 1%. Two types of transducers have been developed: one measures the heart rate and the other the skin temperature. Other transducers remain to be developed. Component circuits were tested at varying environmental temperatures, and a prototype of the whole system was tested on an arctic exercise.","abstract_has_math":false,"creators":["Deczky, Andrew G."],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1968,"date_issued":"1968","date_published":"1968","updated_at":"2026-11-19T14:49:09Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/36076","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/36076","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/36076/1/UBC_1968_A7+D52.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F36076","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Deczky, Andrew G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1968"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/36076","http://circle.library.ubc.ca/bitstream/2429/36076/1/UBC_1968_A7+D52.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Equipment was designed and constructed to monitor automatically and unobtrusively up to twelve physiological variables on a human subject engaged in a prolonged field exercise. Inputs from transducers are sampled in turn, and are encoded into 7-digit PCM. They are then recorded on a small tape-recorder worn by the subject. All equipment is battery-operated, but the recorder and digital circuitry is energized for only 1/2 second every 30 seconds. This, permits recording for over 24 hours without interruptions for a change of battery or tape cassette. A decoder and de-commutator were built so that the tapes can be played back later in the laboratory. Selected parameters can be viewed on an oscilloscope or plotted on a chart-recorder. Overall accuracy of the system is 1%. Two types of transducers have been developed: one measures the heart rate and the other the skin temperature. Other transducers remain to be developed. Component circuits were tested at varying environmental temperatures, and a prototype of the whole system was tested on an arctic exercise."]},{"key":"dc:format","label":"Dc Format","values":["4635896","application/pdf"]},{"key":"dc:title","label":"Title","values":["A portable physiological recording system"]}]}],"canonical_facts":{"dc:creator":["Deczky, Andrew G."],"dc:date":["1968"],"dc:description":["Equipment was designed and constructed to monitor automatically and unobtrusively up to twelve physiological variables on a human subject engaged in a prolonged field exercise. Inputs from transducers are sampled in turn, and are encoded into 7-digit PCM. They are then recorded on a small tape-recorder worn by the subject. All equipment is battery-operated, but the recorder and digital circuitry is energized for only 1/2 second every 30 seconds. This, permits recording for over 24 hours without interruptions for a change of battery or tape cassette. A decoder and de-commutator were built so that the tapes can be played back later in the laboratory. Selected parameters can be viewed on an oscilloscope or plotted on a chart-recorder. Overall accuracy of the system is 1%. Two types of transducers have been developed: one measures the heart rate and the other the skin temperature. Other transducers remain to be developed. Component circuits were tested at varying environmental temperatures, and a prototype of the whole system was tested on an arctic exercise."],"dc:format":["4635896","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/36076","http://circle.library.ubc.ca/bitstream/2429/36076/1/UBC_1968_A7+D52.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A portable physiological recording system"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:49:09Z"}