{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/36093"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/36093","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Determination of conductor clearances-to-ground for EHV AC and DC transmission lines","abstract":"The analyses presented in this thesis are based on a consideration of induction effects below transmission lines and the hazards as presented to the public. The rapid increase of transmission voltages has caused a great deal of concern among utilities about these hazards. The induction effects are a function of line height and at present there is conflict concerning-these dimensions. Primarily, this thesis is concerned with the establishment of the minimum line-to-ground clearances of EHV ac and dc transmission lines. These clearances are established in terms of the electric field under the line based on the \"electric field recognition level\". Equations are derived for the electric field, and potential at any point below the line in Chapter 2. These equations are then used in Chapter 3 to show the effect of conductor spacing, height and size on the field. Also, the effect of sky wires and bundle conductors is noted. Chapter 4 derives an allowable value of electric field which is used in Chapter 5 to derive the required heights. Chapter 6 considers a reduction of these clearances or induction effects using ground wires below the line conductors for shielding purposes. Experimental readings are obtained in Chapter 7 to verify the equations derived in Chapter 2 and the effects of sky wires and bundle conductors on the electric field below the line. Chapter 8 establishes right-of-way widths based on induction effects.","abstract_html":"The analyses presented in this thesis are based on a consideration of induction effects below transmission lines and the hazards as presented to the public. The rapid increase of transmission voltages has caused a great deal of concern among utilities about these hazards. The induction effects are a function of line height and at present there is conflict concerning-these dimensions. Primarily, this thesis is concerned with the establishment of the minimum line-to-ground clearances of EHV ac and dc transmission lines. These clearances are established in terms of the electric field under the line based on the &quot;electric field recognition level&quot;. Equations are derived for the electric field, and potential at any point below the line in Chapter 2. These equations are then used in Chapter 3 to show the effect of conductor spacing, height and size on the field. Also, the effect of sky wires and bundle conductors is noted. Chapter 4 derives an allowable value of electric field which is used in Chapter 5 to derive the required heights. Chapter 6 considers a reduction of these clearances or induction effects using ground wires below the line conductors for shielding purposes. Experimental readings are obtained in Chapter 7 to verify the equations derived in Chapter 2 and the effects of sky wires and bundle conductors on the electric field below the line. Chapter 8 establishes right-of-way widths based on induction effects.","abstract_has_math":false,"creators":["Stremlaw, Arthur John"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1968,"date_issued":"1968","date_published":"1968","updated_at":"2026-11-19T14:49:09Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/36093","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/36093","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/36093/1/UBC_1968_A7+S87.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F36093","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Stremlaw, Arthur John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1968"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/36093","http://circle.library.ubc.ca/bitstream/2429/36093/1/UBC_1968_A7+S87.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The analyses presented in this thesis are based on a consideration of induction effects below transmission lines and the hazards as presented to the public. The rapid increase of transmission voltages has caused a great deal of concern among utilities about these hazards. The induction effects are a function of line height and at present there is conflict concerning-these dimensions. Primarily, this thesis is concerned with the establishment of the minimum line-to-ground clearances of EHV ac and dc transmission lines. These clearances are established in terms of the electric field under the line based on the \"electric field recognition level\". Equations are derived for the electric field, and potential at any point below the line in Chapter 2. These equations are then used in Chapter 3 to show the effect of conductor spacing, height and size on the field. Also, the effect of sky wires and bundle conductors is noted. Chapter 4 derives an allowable value of electric field which is used in Chapter 5 to derive the required heights. Chapter 6 considers a reduction of these clearances or induction effects using ground wires below the line conductors for shielding purposes. Experimental readings are obtained in Chapter 7 to verify the equations derived in Chapter 2 and the effects of sky wires and bundle conductors on the electric field below the line. Chapter 8 establishes right-of-way widths based on induction effects."]},{"key":"dc:format","label":"Dc Format","values":["4236755","application/pdf"]},{"key":"dc:title","label":"Title","values":["Determination of conductor clearances-to-ground for EHV AC and DC transmission lines"]}]}],"canonical_facts":{"dc:creator":["Stremlaw, Arthur John"],"dc:date":["1968"],"dc:description":["The analyses presented in this thesis are based on a consideration of induction effects below transmission lines and the hazards as presented to the public. The rapid increase of transmission voltages has caused a great deal of concern among utilities about these hazards. The induction effects are a function of line height and at present there is conflict concerning-these dimensions. Primarily, this thesis is concerned with the establishment of the minimum line-to-ground clearances of EHV ac and dc transmission lines. These clearances are established in terms of the electric field under the line based on the \"electric field recognition level\". Equations are derived for the electric field, and potential at any point below the line in Chapter 2. These equations are then used in Chapter 3 to show the effect of conductor spacing, height and size on the field. Also, the effect of sky wires and bundle conductors is noted. Chapter 4 derives an allowable value of electric field which is used in Chapter 5 to derive the required heights. Chapter 6 considers a reduction of these clearances or induction effects using ground wires below the line conductors for shielding purposes. Experimental readings are obtained in Chapter 7 to verify the equations derived in Chapter 2 and the effects of sky wires and bundle conductors on the electric field below the line. Chapter 8 establishes right-of-way widths based on induction effects."],"dc:format":["4236755","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/36093","http://circle.library.ubc.ca/bitstream/2429/36093/1/UBC_1968_A7+S87.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Determination of conductor clearances-to-ground for EHV AC and DC transmission lines"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:49:09Z"}