{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/36404"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/36404","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics","abstract":"The development of a high-resolution gamma ray spectrometer incorporating a germanium lithium-drift radiation detector is described. Sources of electrical noise in detectors and low-noise field-effect transistor preamplifiers are discussed. Modifications were made to available preamplifier circuits with a slight improvement in noise characteristics. A very-low-noise preamplifier using a 2N3823 field-effect transistor was tested, and an unconventional design inductive-load field-effect transistor preamplifier was built and tested. Refinements on germanium detector preparation techniques previously in use are described with particular reference to the starting material used. The design of a stainless steel cryostat to house germanium detectors is discussed. Performance characteristics of a 5 cc. detector are given. Preliminary measurements with it of the Doppler broadening of the annihilation peak in Ni and Zn are presented. A spectrum of annihilations of ortho-positronium formed in Freon 12 is given. The detector system is evaluated with reference to suitability in positron physics.","abstract_html":"The development of a high-resolution gamma ray spectrometer incorporating a germanium lithium-drift radiation detector is described. Sources of electrical noise in detectors and low-noise field-effect transistor preamplifiers are discussed. Modifications were made to available preamplifier circuits with a slight improvement in noise characteristics. A very-low-noise preamplifier using a 2N3823 field-effect transistor was tested, and an unconventional design inductive-load field-effect transistor preamplifier was built and tested. Refinements on germanium detector preparation techniques previously in use are described with particular reference to the starting material used. The design of a stainless steel cryostat to house germanium detectors is discussed. Performance characteristics of a 5 cc. detector are given. Preliminary measurements with it of the Doppler broadening of the annihilation peak in Ni and Zn are presented. A spectrum of annihilations of ortho-positronium formed in Freon 12 is given. The detector system is evaluated with reference to suitability in positron physics.","abstract_has_math":false,"creators":["Dably, David Allan"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967","date_published":"1967","updated_at":"2026-11-19T14:49:23Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/36404","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/36404","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/36404/1/UBC_1967_A6_7+D24.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F36404","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dably, David Allan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1967"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/36404","http://circle.library.ubc.ca/bitstream/2429/36404/1/UBC_1967_A6_7+D24.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The development of a high-resolution gamma ray spectrometer incorporating a germanium lithium-drift radiation detector is described. Sources of electrical noise in detectors and low-noise field-effect transistor preamplifiers are discussed. Modifications were made to available preamplifier circuits with a slight improvement in noise characteristics. A very-low-noise preamplifier using a 2N3823 field-effect transistor was tested, and an unconventional design inductive-load field-effect transistor preamplifier was built and tested. Refinements on germanium detector preparation techniques previously in use are described with particular reference to the starting material used. The design of a stainless steel cryostat to house germanium detectors is discussed. Performance characteristics of a 5 cc. detector are given. Preliminary measurements with it of the Doppler broadening of the annihilation peak in Ni and Zn are presented. A spectrum of annihilations of ortho-positronium formed in Freon 12 is given. The detector system is evaluated with reference to suitability in positron physics."]},{"key":"dc:format","label":"Dc Format","values":["3760138","application/pdf"]},{"key":"dc:title","label":"Title","values":["The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics"]}]}],"canonical_facts":{"dc:creator":["Dably, David Allan"],"dc:date":["1967"],"dc:description":["The development of a high-resolution gamma ray spectrometer incorporating a germanium lithium-drift radiation detector is described. Sources of electrical noise in detectors and low-noise field-effect transistor preamplifiers are discussed. Modifications were made to available preamplifier circuits with a slight improvement in noise characteristics. A very-low-noise preamplifier using a 2N3823 field-effect transistor was tested, and an unconventional design inductive-load field-effect transistor preamplifier was built and tested. Refinements on germanium detector preparation techniques previously in use are described with particular reference to the starting material used. The design of a stainless steel cryostat to house germanium detectors is discussed. Performance characteristics of a 5 cc. detector are given. Preliminary measurements with it of the Doppler broadening of the annihilation peak in Ni and Zn are presented. A spectrum of annihilations of ortho-positronium formed in Freon 12 is given. The detector system is evaluated with reference to suitability in positron physics."],"dc:format":["3760138","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/36404","http://circle.library.ubc.ca/bitstream/2429/36404/1/UBC_1967_A6_7+D24.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:49:23Z"}