{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/36570"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/36570","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Time domain studies of short period teleseismic P phases","abstract":"Forty-one seismic events recorded on the plains of western Alberta are subjected to a detailed study in the time domain. A \"P-detection\" time-varying polarization filter is described and applied to the events to detect segments of strong P motion in the first 25 seconds of the P phase coda. On seismograms of 23 events, 12 of which have reported depths shallower than 40 km, pP phases have been identified; sP phases have been identified on 9 of the events. Considering estimated accuracies of observed and calculated pP-P times, assigned focal depths are accurate to within ±15 km. A varying upper crustal structure is found to make a similar contribution to the vertical components of the P phase for stations at separations up to 160 km. The radial components at these stations are similar only during time segments of strong P motion. The dissimilarity in other time segments of the radial components is attributed to different amplitudes and time-delays for PS converted phases generated at crustal layer interfaces. The largest PS converted phase, with amplitude up to about 1.5 that of P, is generated at the base of the sediments. A small number of PS converted phases generated at the base of the crust have been identified.","abstract_html":"Forty-one seismic events recorded on the plains of western Alberta are subjected to a detailed study in the time domain. A &quot;P-detection&quot; time-varying polarization filter is described and applied to the events to detect segments of strong P motion in the first 25 seconds of the P phase coda. On seismograms of 23 events, 12 of which have reported depths shallower than 40 km, pP phases have been identified; sP phases have been identified on 9 of the events. Considering estimated accuracies of observed and calculated pP-P times, assigned focal depths are accurate to within ±15 km. A varying upper crustal structure is found to make a similar contribution to the vertical components of the P phase for stations at separations up to 160 km. The radial components at these stations are similar only during time segments of strong P motion. The dissimilarity in other time segments of the radial components is attributed to different amplitudes and time-delays for PS converted phases generated at crustal layer interfaces. The largest PS converted phase, with amplitude up to about 1.5 that of P, is generated at the base of the sediments. A small number of PS converted phases generated at the base of the crust have been identified.","abstract_has_math":false,"creators":["Basham, Peter William"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Geophysics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967","date_published":"1967","updated_at":"2026-11-19T14:49:26Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/36570","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/36570","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/36570/1/UBC_1967_A7+B38.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F36570","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Basham, Peter William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1967"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Geophysics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/36570","http://circle.library.ubc.ca/bitstream/2429/36570/1/UBC_1967_A7+B38.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Forty-one seismic events recorded on the plains of western Alberta are subjected to a detailed study in the time domain. A \"P-detection\" time-varying polarization filter is described and applied to the events to detect segments of strong P motion in the first 25 seconds of the P phase coda. On seismograms of 23 events, 12 of which have reported depths shallower than 40 km, pP phases have been identified; sP phases have been identified on 9 of the events. Considering estimated accuracies of observed and calculated pP-P times, assigned focal depths are accurate to within ±15 km. A varying upper crustal structure is found to make a similar contribution to the vertical components of the P phase for stations at separations up to 160 km. The radial components at these stations are similar only during time segments of strong P motion. The dissimilarity in other time segments of the radial components is attributed to different amplitudes and time-delays for PS converted phases generated at crustal layer interfaces. The largest PS converted phase, with amplitude up to about 1.5 that of P, is generated at the base of the sediments. A small number of PS converted phases generated at the base of the crust have been identified."]},{"key":"dc:format","label":"Dc Format","values":["8375782","application/pdf"]},{"key":"dc:title","label":"Title","values":["Time domain studies of short period teleseismic P phases"]}]}],"canonical_facts":{"dc:creator":["Basham, Peter William"],"dc:date":["1967"],"dc:description":["Forty-one seismic events recorded on the plains of western Alberta are subjected to a detailed study in the time domain. A \"P-detection\" time-varying polarization filter is described and applied to the events to detect segments of strong P motion in the first 25 seconds of the P phase coda. On seismograms of 23 events, 12 of which have reported depths shallower than 40 km, pP phases have been identified; sP phases have been identified on 9 of the events. Considering estimated accuracies of observed and calculated pP-P times, assigned focal depths are accurate to within ±15 km. A varying upper crustal structure is found to make a similar contribution to the vertical components of the P phase for stations at separations up to 160 km. The radial components at these stations are similar only during time segments of strong P motion. The dissimilarity in other time segments of the radial components is attributed to different amplitudes and time-delays for PS converted phases generated at crustal layer interfaces. The largest PS converted phase, with amplitude up to about 1.5 that of P, is generated at the base of the sediments. A small number of PS converted phases generated at the base of the crust have been identified."],"dc:format":["8375782","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/36570","http://circle.library.ubc.ca/bitstream/2429/36570/1/UBC_1967_A7+B38.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Time domain studies of short period teleseismic P phases"],"dc:type":["Text"],"thesis:degree_discipline":["Geophysics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:49:26Z"}