{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/3666"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/3666","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Phase-domain synchronous generator model for transients simulation","abstract":"Three-phase synchronous generators which convert mechanical energy into electrical energy are the main power sources of power systems. In this thesis a phase-domain synchronous generator model which is developed directly in the stator reference frame is presented. The electrical and mechanical parts of a three-phase synchronous generator are separately modeled by two different, sets of differential equations which are discretized with the trapezoidal rule of integration. These two parts are linked together by the rotor position angle and the electromagnetic torque generated by the interactions of the different magnetic fields, resulting in a linear generator model. In order to represent the generator more accurately, the linear generator model is modified to include magnetic saturation effects, resulting in a non-linear generator model. A formula is developed to account for the saturation as a function of the rotor angle and the total magnetomotive force angle. The machine parameters in the stator reference frame are obtained from the given characteristic quantities by a suitable data conversion scheme. To verify the linear generator model, a comparison between the simulation results of a three-phase short-circuit at the terminals of the machine obtained with the new linear model and the model in the EMTP is conducted.","abstract_html":"Three-phase synchronous generators which convert mechanical energy into electrical energy are the main power sources of power systems. In this thesis a phase-domain synchronous generator model which is developed directly in the stator reference frame is presented. The electrical and mechanical parts of a three-phase synchronous generator are separately modeled by two different, sets of differential equations which are discretized with the trapezoidal rule of integration. These two parts are linked together by the rotor position angle and the electromagnetic torque generated by the interactions of the different magnetic fields, resulting in a linear generator model. In order to represent the generator more accurately, the linear generator model is modified to include magnetic saturation effects, resulting in a non-linear generator model. A formula is developed to account for the saturation as a function of the rotor angle and the total magnetomotive force angle. The machine parameters in the stator reference frame are obtained from the given characteristic quantities by a suitable data conversion scheme. To verify the linear generator model, a comparison between the simulation results of a three-phase short-circuit at the terminals of the machine obtained with the new linear model and the model in the EMTP is conducted.","abstract_has_math":false,"creators":["Louie, Kwok Wai"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-19T14:23:57Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/3666","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/3666","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/3666/1/ubc_1995-0226.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F3666","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Louie, Kwok Wai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/3666","http://circle.library.ubc.ca/bitstream/2429/3666/1/ubc_1995-0226.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Three-phase synchronous generators which convert mechanical energy into electrical energy are the main power sources of power systems. In this thesis a phase-domain synchronous generator model which is developed directly in the stator reference frame is presented. The electrical and mechanical parts of a three-phase synchronous generator are separately modeled by two different, sets of differential equations which are discretized with the trapezoidal rule of integration. These two parts are linked together by the rotor position angle and the electromagnetic torque generated by the interactions of the different magnetic fields, resulting in a linear generator model. In order to represent the generator more accurately, the linear generator model is modified to include magnetic saturation effects, resulting in a non-linear generator model. A formula is developed to account for the saturation as a function of the rotor angle and the total magnetomotive force angle. The machine parameters in the stator reference frame are obtained from the given characteristic quantities by a suitable data conversion scheme. To verify the linear generator model, a comparison between the simulation results of a three-phase short-circuit at the terminals of the machine obtained with the new linear model and the model in the EMTP is conducted."]},{"key":"dc:format","label":"Dc Format","values":["2597532","application/pdf"]},{"key":"dc:title","label":"Title","values":["Phase-domain synchronous generator model for transients simulation"]}]}],"canonical_facts":{"dc:creator":["Louie, Kwok Wai"],"dc:date":["1995"],"dc:description":["Three-phase synchronous generators which convert mechanical energy into electrical energy are the main power sources of power systems. In this thesis a phase-domain synchronous generator model which is developed directly in the stator reference frame is presented. The electrical and mechanical parts of a three-phase synchronous generator are separately modeled by two different, sets of differential equations which are discretized with the trapezoidal rule of integration. These two parts are linked together by the rotor position angle and the electromagnetic torque generated by the interactions of the different magnetic fields, resulting in a linear generator model. In order to represent the generator more accurately, the linear generator model is modified to include magnetic saturation effects, resulting in a non-linear generator model. A formula is developed to account for the saturation as a function of the rotor angle and the total magnetomotive force angle. The machine parameters in the stator reference frame are obtained from the given characteristic quantities by a suitable data conversion scheme. To verify the linear generator model, a comparison between the simulation results of a three-phase short-circuit at the terminals of the machine obtained with the new linear model and the model in the EMTP is conducted."],"dc:format":["2597532","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/3666","http://circle.library.ubc.ca/bitstream/2429/3666/1/ubc_1995-0226.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Phase-domain synchronous generator model for transients simulation"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:23:57Z"}