{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/37220"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/37220","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Implementation of respiratory-correlated cone-beam CT on Varian linac systems","abstract":"Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient's breathing cycle. In external beam radiotherapy, information about a tumor's motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately aligned for treatment. Cone-beam CT (CBCT) systems are becoming widespread on treatment linac units and are used to aid in alignment. This thesis describes the implementation of respiratory-correlated cone-beam CT scans on two types of Varian units: iX and TrueBeam. Procedures for 4D CBCT scans on each type have been developed and used to image a moving phantom. The respiratory phase of the motion is recorded with the Varian Real-time Position Management (RPM) system, which uses optical tracking. To improve image quality, the gantry rotation speed is reduced below the default value of 6°/s: this reduces streak artifacts. Each projection image from the scan is assigned to one of ten phase bins according to its respiratory phase value. A 3D image is reconstructed for each phase bin with software developed for this project, which uses conventional Feldkamp-Davis-Kress filtered backprojection. Four 4D scans of a periodically moving phantom have been taken, with different gantry speeds and mAs values. To evaluate the effect of these scan parameters on image quality, and demonstrate a potential application of 4D CBCT, a procedure for automated tumor trajectory measurement has been developed. The measurement uses image registration between phase images, with either a rigid translation or a B-spline deformation algorithm. In the highest-quality images, the displacements of an insert in the phantom are measured within 1 mm of the correct values by both algorithms. In lower-quality images the translation algorithm is more robust. The two algorithms give similar results when applied to 4D CT images of actual lung cancer patients.","abstract_html":"Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient&#x27;s breathing cycle. In external beam radiotherapy, information about a tumor&#x27;s motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately aligned for treatment. Cone-beam CT (CBCT) systems are becoming widespread on treatment linac units and are used to aid in alignment. This thesis describes the implementation of respiratory-correlated cone-beam CT scans on two types of Varian units: iX and TrueBeam. Procedures for 4D CBCT scans on each type have been developed and used to image a moving phantom. The respiratory phase of the motion is recorded with the Varian Real-time Position Management (RPM) system, which uses optical tracking. To improve image quality, the gantry rotation speed is reduced below the default value of 6°/s: this reduces streak artifacts. Each projection image from the scan is assigned to one of ten phase bins according to its respiratory phase value. A 3D image is reconstructed for each phase bin with software developed for this project, which uses conventional Feldkamp-Davis-Kress filtered backprojection. Four 4D scans of a periodically moving phantom have been taken, with different gantry speeds and mAs values. To evaluate the effect of these scan parameters on image quality, and demonstrate a potential application of 4D CBCT, a procedure for automated tumor trajectory measurement has been developed. The measurement uses image registration between phase images, with either a rigid translation or a B-spline deformation algorithm. In the highest-quality images, the displacements of an insert in the phantom are measured within 1 mm of the correct values by both algorithms. In lower-quality images the translation algorithm is more robust. The two algorithms give similar results when applied to 4D CT images of actual lung cancer patients.","abstract_has_math":false,"creators":["Cropp, Robert James"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-19T14:49:43Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/37220","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/37220","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/37220/1/ubc_2011_fall_cropp_robert.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F37220","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cropp, Robert James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/37220","http://circle.library.ubc.ca/bitstream/2429/37220/1/ubc_2011_fall_cropp_robert.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient's breathing cycle. In external beam radiotherapy, information about a tumor's motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately aligned for treatment. Cone-beam CT (CBCT) systems are becoming widespread on treatment linac units and are used to aid in alignment. This thesis describes the implementation of respiratory-correlated cone-beam CT scans on two types of Varian units: iX and TrueBeam. Procedures for 4D CBCT scans on each type have been developed and used to image a moving phantom. The respiratory phase of the motion is recorded with the Varian Real-time Position Management (RPM) system, which uses optical tracking. To improve image quality, the gantry rotation speed is reduced below the default value of 6°/s: this reduces streak artifacts. Each projection image from the scan is assigned to one of ten phase bins according to its respiratory phase value. A 3D image is reconstructed for each phase bin with software developed for this project, which uses conventional Feldkamp-Davis-Kress filtered backprojection. Four 4D scans of a periodically moving phantom have been taken, with different gantry speeds and mAs values. To evaluate the effect of these scan parameters on image quality, and demonstrate a potential application of 4D CBCT, a procedure for automated tumor trajectory measurement has been developed. The measurement uses image registration between phase images, with either a rigid translation or a B-spline deformation algorithm. In the highest-quality images, the displacements of an insert in the phantom are measured within 1 mm of the correct values by both algorithms. In lower-quality images the translation algorithm is more robust. The two algorithms give similar results when applied to 4D CT images of actual lung cancer patients."]},{"key":"dc:format","label":"Dc Format","values":["6129434","application/pdf"]},{"key":"dc:title","label":"Title","values":["Implementation of respiratory-correlated cone-beam CT on Varian linac systems"]}]}],"canonical_facts":{"dc:creator":["Cropp, Robert James"],"dc:date":["2011"],"dc:description":["Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient's breathing cycle. In external beam radiotherapy, information about a tumor's motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately aligned for treatment. Cone-beam CT (CBCT) systems are becoming widespread on treatment linac units and are used to aid in alignment. This thesis describes the implementation of respiratory-correlated cone-beam CT scans on two types of Varian units: iX and TrueBeam. Procedures for 4D CBCT scans on each type have been developed and used to image a moving phantom. The respiratory phase of the motion is recorded with the Varian Real-time Position Management (RPM) system, which uses optical tracking. To improve image quality, the gantry rotation speed is reduced below the default value of 6°/s: this reduces streak artifacts. Each projection image from the scan is assigned to one of ten phase bins according to its respiratory phase value. A 3D image is reconstructed for each phase bin with software developed for this project, which uses conventional Feldkamp-Davis-Kress filtered backprojection. Four 4D scans of a periodically moving phantom have been taken, with different gantry speeds and mAs values. To evaluate the effect of these scan parameters on image quality, and demonstrate a potential application of 4D CBCT, a procedure for automated tumor trajectory measurement has been developed. The measurement uses image registration between phase images, with either a rigid translation or a B-spline deformation algorithm. In the highest-quality images, the displacements of an insert in the phantom are measured within 1 mm of the correct values by both algorithms. In lower-quality images the translation algorithm is more robust. The two algorithms give similar results when applied to 4D CT images of actual lung cancer patients."],"dc:format":["6129434","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/37220","http://circle.library.ubc.ca/bitstream/2429/37220/1/ubc_2011_fall_cropp_robert.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Implementation of respiratory-correlated cone-beam CT on Varian linac systems"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:49:43Z"}