{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/37722"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/37722","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Effect of ground conductivity and permittivity on the mode propagation constants of an overhead transmission line","abstract":"A general analytical method to derive the distributed circuit parameters and mode propagation constants for an n-conductor transmission line is developed. The analysis uses electromagnetic field concepts and the results are interpreted in terms of distributed circuit parameters. The procedure involves transforming the problem of the n-conductor line above a ground with finite conductivity into that of an n-conductor above a ground with infinite conductivity. Correction factors are added to account for the finite conductivity of the ground. The distributed circuit parameters thus calculated are used to calculate the mode propagation constants over a frequency range from 10 Hz to 1 MHz for values of ground conductivity varying between 1 mho/m and 10⁻⁵ mho/m and relative permittivity varying between 10 and 50. Numerical results for the distributed circuit parameters and mode propagation constants for a typical 500 kV single circuit transmission line and various ground conditions are given. The results show that one mode has a higher attenuation and a lower velocity than either of the other two modes, suggesting the zero sequence mode for a completely balanced system.","abstract_html":"A general analytical method to derive the distributed circuit parameters and mode propagation constants for an n-conductor transmission line is developed. The analysis uses electromagnetic field concepts and the results are interpreted in terms of distributed circuit parameters. The procedure involves transforming the problem of the n-conductor line above a ground with finite conductivity into that of an n-conductor above a ground with infinite conductivity. Correction factors are added to account for the finite conductivity of the ground. The distributed circuit parameters thus calculated are used to calculate the mode propagation constants over a frequency range from 10 Hz to 1 MHz for values of ground conductivity varying between 1 mho/m and 10⁻⁵ mho/m and relative permittivity varying between 10 and 50. Numerical results for the distributed circuit parameters and mode propagation constants for a typical 500 kV single circuit transmission line and various ground conditions are given. The results show that one mode has a higher attenuation and a lower velocity than either of the other two modes, suggesting the zero sequence mode for a completely balanced system.","abstract_has_math":false,"creators":["Doench, Claus"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1966,"date_issued":"1966","date_published":"1966","updated_at":"2026-11-19T14:50:03Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/37722","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/37722","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/37722/1/UBC_1966_A7+D65.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F37722","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Doench, Claus"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1966"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/37722","http://circle.library.ubc.ca/bitstream/2429/37722/1/UBC_1966_A7+D65.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A general analytical method to derive the distributed circuit parameters and mode propagation constants for an n-conductor transmission line is developed. The analysis uses electromagnetic field concepts and the results are interpreted in terms of distributed circuit parameters. The procedure involves transforming the problem of the n-conductor line above a ground with finite conductivity into that of an n-conductor above a ground with infinite conductivity. Correction factors are added to account for the finite conductivity of the ground. The distributed circuit parameters thus calculated are used to calculate the mode propagation constants over a frequency range from 10 Hz to 1 MHz for values of ground conductivity varying between 1 mho/m and 10⁻⁵ mho/m and relative permittivity varying between 10 and 50. Numerical results for the distributed circuit parameters and mode propagation constants for a typical 500 kV single circuit transmission line and various ground conditions are given. The results show that one mode has a higher attenuation and a lower velocity than either of the other two modes, suggesting the zero sequence mode for a completely balanced system."]},{"key":"dc:format","label":"Dc Format","values":["5099257","application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of ground conductivity and permittivity on the mode propagation constants of an overhead transmission line"]}]}],"canonical_facts":{"dc:creator":["Doench, Claus"],"dc:date":["1966"],"dc:description":["A general analytical method to derive the distributed circuit parameters and mode propagation constants for an n-conductor transmission line is developed. The analysis uses electromagnetic field concepts and the results are interpreted in terms of distributed circuit parameters. The procedure involves transforming the problem of the n-conductor line above a ground with finite conductivity into that of an n-conductor above a ground with infinite conductivity. Correction factors are added to account for the finite conductivity of the ground. The distributed circuit parameters thus calculated are used to calculate the mode propagation constants over a frequency range from 10 Hz to 1 MHz for values of ground conductivity varying between 1 mho/m and 10⁻⁵ mho/m and relative permittivity varying between 10 and 50. Numerical results for the distributed circuit parameters and mode propagation constants for a typical 500 kV single circuit transmission line and various ground conditions are given. The results show that one mode has a higher attenuation and a lower velocity than either of the other two modes, suggesting the zero sequence mode for a completely balanced system."],"dc:format":["5099257","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/37722","http://circle.library.ubc.ca/bitstream/2429/37722/1/UBC_1966_A7+D65.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Effect of ground conductivity and permittivity on the mode propagation constants of an overhead transmission line"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:03Z"}