{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/37817"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/37817","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"He3 cryostat for steady state nuclear magnetic resonance measurements in metals","abstract":"A He³ cryostat was designed for steady state nuclear magnetic resonance measurements. The cryostat required about one liter of He³ at NTP. This amount of He³ was liquified at 1.2°K, which was the temperature of the surrounding liquid He⁴ bath, and then pumped on by means of a four-stage mercury diffusion pump. By this procedure, a liquid He³ temperature of 0.35 K was achieved and maintained for four hours. The r-f coil and sample were in direct contact with the liquid He³ to ensure sufficient heat transfer between the two. The temperature of the liquid He³ was measured by means of vapour pressure measurements of the evaporating He³ and by means of resistance measurements of a carbon resistance in contact with the liquid He³. The system was non-recirculating, since a total, uninterrupted run of four hours was considered long enough for most experiments. The He³ could also be retransferred within 20 minutes after such a run, and this process could be continued until in-sufficient quantities of liquid He⁴remained to cool the surroundings.","abstract_html":"A He³ cryostat was designed for steady state nuclear magnetic resonance measurements. The cryostat required about one liter of He³ at NTP. This amount of He³ was liquified at 1.2°K, which was the temperature of the surrounding liquid He⁴ bath, and then pumped on by means of a four-stage mercury diffusion pump. By this procedure, a liquid He³ temperature of 0.35 K was achieved and maintained for four hours. The r-f coil and sample were in direct contact with the liquid He³ to ensure sufficient heat transfer between the two. The temperature of the liquid He³ was measured by means of vapour pressure measurements of the evaporating He³ and by means of resistance measurements of a carbon resistance in contact with the liquid He³. The system was non-recirculating, since a total, uninterrupted run of four hours was considered long enough for most experiments. The He³ could also be retransferred within 20 minutes after such a run, and this process could be continued until in-sufficient quantities of liquid He⁴remained to cool the surroundings.","abstract_has_math":false,"creators":["Puls, Manfred Paul"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1966,"date_issued":"1966","date_published":"1966","updated_at":"2026-11-19T14:50:07Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/37817","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/37817","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/37817/1/UBC_1966_A7+P8.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F37817","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Puls, Manfred Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1966"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/37817","http://circle.library.ubc.ca/bitstream/2429/37817/1/UBC_1966_A7+P8.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A He³ cryostat was designed for steady state nuclear magnetic resonance measurements. The cryostat required about one liter of He³ at NTP. This amount of He³ was liquified at 1.2°K, which was the temperature of the surrounding liquid He⁴ bath, and then pumped on by means of a four-stage mercury diffusion pump. By this procedure, a liquid He³ temperature of 0.35 K was achieved and maintained for four hours. The r-f coil and sample were in direct contact with the liquid He³ to ensure sufficient heat transfer between the two. The temperature of the liquid He³ was measured by means of vapour pressure measurements of the evaporating He³ and by means of resistance measurements of a carbon resistance in contact with the liquid He³. The system was non-recirculating, since a total, uninterrupted run of four hours was considered long enough for most experiments. The He³ could also be retransferred within 20 minutes after such a run, and this process could be continued until in-sufficient quantities of liquid He⁴remained to cool the surroundings."]},{"key":"dc:format","label":"Dc Format","values":["2601284","application/pdf"]},{"key":"dc:title","label":"Title","values":["He3 cryostat for steady state nuclear magnetic resonance measurements in metals"]}]}],"canonical_facts":{"dc:creator":["Puls, Manfred Paul"],"dc:date":["1966"],"dc:description":["A He³ cryostat was designed for steady state nuclear magnetic resonance measurements. The cryostat required about one liter of He³ at NTP. This amount of He³ was liquified at 1.2°K, which was the temperature of the surrounding liquid He⁴ bath, and then pumped on by means of a four-stage mercury diffusion pump. By this procedure, a liquid He³ temperature of 0.35 K was achieved and maintained for four hours. The r-f coil and sample were in direct contact with the liquid He³ to ensure sufficient heat transfer between the two. The temperature of the liquid He³ was measured by means of vapour pressure measurements of the evaporating He³ and by means of resistance measurements of a carbon resistance in contact with the liquid He³. The system was non-recirculating, since a total, uninterrupted run of four hours was considered long enough for most experiments. The He³ could also be retransferred within 20 minutes after such a run, and this process could be continued until in-sufficient quantities of liquid He⁴remained to cool the surroundings."],"dc:format":["2601284","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/37817","http://circle.library.ubc.ca/bitstream/2429/37817/1/UBC_1966_A7+P8.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["He3 cryostat for steady state nuclear magnetic resonance measurements in metals"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:07Z"}