{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/37939"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/37939","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Liquid-liquid mass transfer in cocurrent pipe flow","abstract":"Mass transfer between n-butanol and water has been studied in cocurrent pipeline flow. The apparatus consisted of a feed nozzle, a glass pipe contactor and a gravity settler. Compositions were determined by refractive index measurements. The variables studied were mass input ratio, total flow rate and contactor length. Pressure drop and holdup ratio also have been determined as a function of input ratio and total flow rate. Phase NTU's, determined directly by a method proposed by Colburn and Welsh (10), were found to correlate with individual phase velocities and also were dependent on the input ratio and the contactor length. Mass transfer stage efficiencies varied from near zero to nearly one-hundred per cent. The magnitude of the end effects was estimated by measuring the amount of mass transfer that occurred with virtually zero contactor length before settling. End effects were large. The pipeline contactor was compared to other experimental liquid-liquid extraction devices described in the literature, and was found to be superior in terms of \"contactor effectiveness\" and energy requirements.","abstract_html":"Mass transfer between n-butanol and water has been studied in cocurrent pipeline flow. The apparatus consisted of a feed nozzle, a glass pipe contactor and a gravity settler. Compositions were determined by refractive index measurements. The variables studied were mass input ratio, total flow rate and contactor length. Pressure drop and holdup ratio also have been determined as a function of input ratio and total flow rate. Phase NTU&#x27;s, determined directly by a method proposed by Colburn and Welsh (10), were found to correlate with individual phase velocities and also were dependent on the input ratio and the contactor length. Mass transfer stage efficiencies varied from near zero to nearly one-hundred per cent. The magnitude of the end effects was estimated by measuring the amount of mass transfer that occurred with virtually zero contactor length before settling. End effects were large. The pipeline contactor was compared to other experimental liquid-liquid extraction devices described in the literature, and was found to be superior in terms of &quot;contactor effectiveness&quot; and energy requirements.","abstract_has_math":false,"creators":["Watkinson, Alan Paul"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1966,"date_issued":"1966","date_published":"1966","updated_at":"2026-11-19T14:50:09Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/37939","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/37939","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/37939/1/UBC_1966_A7+W3.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F37939","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Watkinson, Alan Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1966"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/37939","http://circle.library.ubc.ca/bitstream/2429/37939/1/UBC_1966_A7+W3.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Mass transfer between n-butanol and water has been studied in cocurrent pipeline flow. The apparatus consisted of a feed nozzle, a glass pipe contactor and a gravity settler. Compositions were determined by refractive index measurements. The variables studied were mass input ratio, total flow rate and contactor length. Pressure drop and holdup ratio also have been determined as a function of input ratio and total flow rate. Phase NTU's, determined directly by a method proposed by Colburn and Welsh (10), were found to correlate with individual phase velocities and also were dependent on the input ratio and the contactor length. Mass transfer stage efficiencies varied from near zero to nearly one-hundred per cent. The magnitude of the end effects was estimated by measuring the amount of mass transfer that occurred with virtually zero contactor length before settling. End effects were large. The pipeline contactor was compared to other experimental liquid-liquid extraction devices described in the literature, and was found to be superior in terms of \"contactor effectiveness\" and energy requirements."]},{"key":"dc:format","label":"Dc Format","values":["8524651","application/pdf"]},{"key":"dc:title","label":"Title","values":["Liquid-liquid mass transfer in cocurrent pipe flow"]}]}],"canonical_facts":{"dc:creator":["Watkinson, Alan Paul"],"dc:date":["1966"],"dc:description":["Mass transfer between n-butanol and water has been studied in cocurrent pipeline flow. The apparatus consisted of a feed nozzle, a glass pipe contactor and a gravity settler. Compositions were determined by refractive index measurements. The variables studied were mass input ratio, total flow rate and contactor length. Pressure drop and holdup ratio also have been determined as a function of input ratio and total flow rate. Phase NTU's, determined directly by a method proposed by Colburn and Welsh (10), were found to correlate with individual phase velocities and also were dependent on the input ratio and the contactor length. Mass transfer stage efficiencies varied from near zero to nearly one-hundred per cent. The magnitude of the end effects was estimated by measuring the amount of mass transfer that occurred with virtually zero contactor length before settling. End effects were large. The pipeline contactor was compared to other experimental liquid-liquid extraction devices described in the literature, and was found to be superior in terms of \"contactor effectiveness\" and energy requirements."],"dc:format":["8524651","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/37939","http://circle.library.ubc.ca/bitstream/2429/37939/1/UBC_1966_A7+W3.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Liquid-liquid mass transfer in cocurrent pipe flow"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:09Z"}