{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/39561"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/39561","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Design, construction, and operation of a piston type sampler for a liquid-liquid extraction spray column","abstract":"A piston type of sampler was designed and constructed to sample the dispersed phase of a spray liquid-liquid extraction tower. The aim was to check a previous method of sampling the dispersed phase. This method depended on the use of a long probe which descended into the column from above and through which samples were removed by suction. Calculated values of the dispersed phase concentration using the piston type sampler were found to be generally lower than the corresponding concentrations using the dispersed phase probe. The system studied was methyl isobutyl ketone (the dispersed phase)-acetic acid (the solute) - water (the continuous phase). The solute was transfered from the aqueous phase, which was saturated with methyl isobutyl ketone, to the organic phase, which was saturated with water. Mass transfer data were gathered for this system in a 1.5-in. I.D. column which was approximately 7.3-ft. in height.","abstract_html":"A piston type of sampler was designed and constructed to sample the dispersed phase of a spray liquid-liquid extraction tower. The aim was to check a previous method of sampling the dispersed phase. This method depended on the use of a long probe which descended into the column from above and through which samples were removed by suction. Calculated values of the dispersed phase concentration using the piston type sampler were found to be generally lower than the corresponding concentrations using the dispersed phase probe. The system studied was methyl isobutyl ketone (the dispersed phase)-acetic acid (the solute) - water (the continuous phase). The solute was transfered from the aqueous phase, which was saturated with methyl isobutyl ketone, to the organic phase, which was saturated with water. Mass transfer data were gathered for this system in a 1.5-in. I.D. column which was approximately 7.3-ft. in height.","abstract_has_math":false,"creators":["Hawrelak, Richard Alan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1960,"date_issued":"1960","date_published":"1960","updated_at":"2026-11-19T14:50:50Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/39561","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/39561","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/39561/1/UBC_1960_A7+H28+D3.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F39561","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hawrelak, Richard Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1960"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/39561","http://circle.library.ubc.ca/bitstream/2429/39561/1/UBC_1960_A7+H28+D3.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A piston type of sampler was designed and constructed to sample the dispersed phase of a spray liquid-liquid extraction tower. The aim was to check a previous method of sampling the dispersed phase. This method depended on the use of a long probe which descended into the column from above and through which samples were removed by suction. Calculated values of the dispersed phase concentration using the piston type sampler were found to be generally lower than the corresponding concentrations using the dispersed phase probe. The system studied was methyl isobutyl ketone (the dispersed phase)-acetic acid (the solute) - water (the continuous phase). The solute was transfered from the aqueous phase, which was saturated with methyl isobutyl ketone, to the organic phase, which was saturated with water. Mass transfer data were gathered for this system in a 1.5-in. I.D. column which was approximately 7.3-ft. in height."]},{"key":"dc:format","label":"Dc Format","values":["8913528","application/pdf"]},{"key":"dc:title","label":"Title","values":["Design, construction, and operation of a piston type sampler for a liquid-liquid extraction spray column"]}]}],"canonical_facts":{"dc:creator":["Hawrelak, Richard Alan"],"dc:date":["1960"],"dc:description":["A piston type of sampler was designed and constructed to sample the dispersed phase of a spray liquid-liquid extraction tower. The aim was to check a previous method of sampling the dispersed phase. This method depended on the use of a long probe which descended into the column from above and through which samples were removed by suction. Calculated values of the dispersed phase concentration using the piston type sampler were found to be generally lower than the corresponding concentrations using the dispersed phase probe. The system studied was methyl isobutyl ketone (the dispersed phase)-acetic acid (the solute) - water (the continuous phase). The solute was transfered from the aqueous phase, which was saturated with methyl isobutyl ketone, to the organic phase, which was saturated with water. Mass transfer data were gathered for this system in a 1.5-in. I.D. column which was approximately 7.3-ft. in height."],"dc:format":["8913528","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/39561","http://circle.library.ubc.ca/bitstream/2429/39561/1/UBC_1960_A7+H28+D3.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Design, construction, and operation of a piston type sampler for a liquid-liquid extraction spray column"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:50Z"}