{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/39564"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/39564","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Stress distribution in some common welded beam-to-column connections","abstract":"This is a report on tests of welded beam-to-column connections carried out in the Materials Testing Laboratory, Department of Civil Engineering, University of British Columbia. The test series included four basic types of connection commonly used in practice, and for each type, a set of stress distribution curves has been given for each part of the connection. Realizing also, that for a connection to be of any practical use, it must have adequate rotation capacity, moment-rotation curves have also been given. From the various stress curves given, an attempt has been made to tabulate magnification factors, which are described in the text, and in this way correlate the peak stress values obtained with the theoretical linear stresses assumed. In order to do this for the column of each connection, a linear stress distribution was assumed, using information obtained from the tests carried out. Finally, the calculated values for each connection are compared in the concluding section.","abstract_html":"This is a report on tests of welded beam-to-column connections carried out in the Materials Testing Laboratory, Department of Civil Engineering, University of British Columbia. The test series included four basic types of connection commonly used in practice, and for each type, a set of stress distribution curves has been given for each part of the connection. Realizing also, that for a connection to be of any practical use, it must have adequate rotation capacity, moment-rotation curves have also been given. From the various stress curves given, an attempt has been made to tabulate magnification factors, which are described in the text, and in this way correlate the peak stress values obtained with the theoretical linear stresses assumed. In order to do this for the column of each connection, a linear stress distribution was assumed, using information obtained from the tests carried out. Finally, the calculated values for each connection are compared in the concluding section.","abstract_has_math":false,"creators":["Nicholls, Jack Ivan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1960,"date_issued":"1960","date_published":"1960","updated_at":"2026-11-19T14:50:50Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/39564","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/39564","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/39564/1/UBC_1960_A7+N4+S8.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F39564","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nicholls, Jack Ivan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1960"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/39564","http://circle.library.ubc.ca/bitstream/2429/39564/1/UBC_1960_A7+N4+S8.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This is a report on tests of welded beam-to-column connections carried out in the Materials Testing Laboratory, Department of Civil Engineering, University of British Columbia. The test series included four basic types of connection commonly used in practice, and for each type, a set of stress distribution curves has been given for each part of the connection. Realizing also, that for a connection to be of any practical use, it must have adequate rotation capacity, moment-rotation curves have also been given. From the various stress curves given, an attempt has been made to tabulate magnification factors, which are described in the text, and in this way correlate the peak stress values obtained with the theoretical linear stresses assumed. In order to do this for the column of each connection, a linear stress distribution was assumed, using information obtained from the tests carried out. Finally, the calculated values for each connection are compared in the concluding section."]},{"key":"dc:format","label":"Dc Format","values":["9163672","application/pdf"]},{"key":"dc:title","label":"Title","values":["Stress distribution in some common welded beam-to-column connections"]}]}],"canonical_facts":{"dc:creator":["Nicholls, Jack Ivan"],"dc:date":["1960"],"dc:description":["This is a report on tests of welded beam-to-column connections carried out in the Materials Testing Laboratory, Department of Civil Engineering, University of British Columbia. The test series included four basic types of connection commonly used in practice, and for each type, a set of stress distribution curves has been given for each part of the connection. Realizing also, that for a connection to be of any practical use, it must have adequate rotation capacity, moment-rotation curves have also been given. From the various stress curves given, an attempt has been made to tabulate magnification factors, which are described in the text, and in this way correlate the peak stress values obtained with the theoretical linear stresses assumed. In order to do this for the column of each connection, a linear stress distribution was assumed, using information obtained from the tests carried out. Finally, the calculated values for each connection are compared in the concluding section."],"dc:format":["9163672","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/39564","http://circle.library.ubc.ca/bitstream/2429/39564/1/UBC_1960_A7+N4+S8.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Stress distribution in some common welded beam-to-column connections"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:50Z"}