{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/39621"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/39621","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Size effects in copper whiskers","abstract":"Whiskers were grown by the hydrogen reduction of cupric chloride. Tensile tests were performed on the whiskers, some of which were long enough to divide into two or three parts. After the whisker yielded (\"primary tests\") they were retested (\"secondary tests\") after removal of the deformed region. In order to see if length had any effect on yield stress, a normalizing proceedure was established to convert the yield stress measured at any diameter d to an equivalent whisker with d = 10 μ. No observable length dependence of yield stress was found for either primary tests or secondary tests. The diameter dependence of yield stress was found to depend on the type of tests. For primary tests, the yield stress was inversely proportional to d¹‧⁶, while for secondary tests, inversely proportional to d²‧⁵. A dislocation mechanism to explain this was proposed in terms of only a part of the cross-sectional area (a small annular ring at the periphery of the whisker) taking part in the deformation. This mechanism was suitable only if the whiskers were assumed to be initially free of dislocations. A decrease in the value of Young's Modulus of about 30% from the normal values was observed for whiskers subjected to a secondary test.","abstract_html":"Whiskers were grown by the hydrogen reduction of cupric chloride. Tensile tests were performed on the whiskers, some of which were long enough to divide into two or three parts. After the whisker yielded (&quot;primary tests&quot;) they were retested (&quot;secondary tests&quot;) after removal of the deformed region. In order to see if length had any effect on yield stress, a normalizing proceedure was established to convert the yield stress measured at any diameter d to an equivalent whisker with d = 10 μ. No observable length dependence of yield stress was found for either primary tests or secondary tests. The diameter dependence of yield stress was found to depend on the type of tests. For primary tests, the yield stress was inversely proportional to d¹‧⁶, while for secondary tests, inversely proportional to d²‧⁵. A dislocation mechanism to explain this was proposed in terms of only a part of the cross-sectional area (a small annular ring at the periphery of the whisker) taking part in the deformation. This mechanism was suitable only if the whiskers were assumed to be initially free of dislocations. A decrease in the value of Young&#x27;s Modulus of about 30% from the normal values was observed for whiskers subjected to a secondary test.","abstract_has_math":false,"creators":["Moore, Zelma Esther"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mining Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1961,"date_issued":"1961","date_published":"1961","updated_at":"2026-11-19T14:50:52Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/39621","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/39621","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/39621/1/UBC_1962_A7+R3+S4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F39621","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Moore, Zelma Esther"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1961"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mining Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/39621","http://circle.library.ubc.ca/bitstream/2429/39621/1/UBC_1962_A7+R3+S4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Whiskers were grown by the hydrogen reduction of cupric chloride. Tensile tests were performed on the whiskers, some of which were long enough to divide into two or three parts. After the whisker yielded (\"primary tests\") they were retested (\"secondary tests\") after removal of the deformed region. In order to see if length had any effect on yield stress, a normalizing proceedure was established to convert the yield stress measured at any diameter d to an equivalent whisker with d = 10 μ. No observable length dependence of yield stress was found for either primary tests or secondary tests. The diameter dependence of yield stress was found to depend on the type of tests. For primary tests, the yield stress was inversely proportional to d¹‧⁶, while for secondary tests, inversely proportional to d²‧⁵. A dislocation mechanism to explain this was proposed in terms of only a part of the cross-sectional area (a small annular ring at the periphery of the whisker) taking part in the deformation. This mechanism was suitable only if the whiskers were assumed to be initially free of dislocations. A decrease in the value of Young's Modulus of about 30% from the normal values was observed for whiskers subjected to a secondary test."]},{"key":"dc:format","label":"Dc Format","values":["6866591","application/pdf"]},{"key":"dc:title","label":"Title","values":["Size effects in copper whiskers"]}]}],"canonical_facts":{"dc:creator":["Moore, Zelma Esther"],"dc:date":["1961"],"dc:description":["Whiskers were grown by the hydrogen reduction of cupric chloride. Tensile tests were performed on the whiskers, some of which were long enough to divide into two or three parts. After the whisker yielded (\"primary tests\") they were retested (\"secondary tests\") after removal of the deformed region. In order to see if length had any effect on yield stress, a normalizing proceedure was established to convert the yield stress measured at any diameter d to an equivalent whisker with d = 10 μ. No observable length dependence of yield stress was found for either primary tests or secondary tests. The diameter dependence of yield stress was found to depend on the type of tests. For primary tests, the yield stress was inversely proportional to d¹‧⁶, while for secondary tests, inversely proportional to d²‧⁵. A dislocation mechanism to explain this was proposed in terms of only a part of the cross-sectional area (a small annular ring at the periphery of the whisker) taking part in the deformation. This mechanism was suitable only if the whiskers were assumed to be initially free of dislocations. A decrease in the value of Young's Modulus of about 30% from the normal values was observed for whiskers subjected to a secondary test."],"dc:format":["6866591","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/39621","http://circle.library.ubc.ca/bitstream/2429/39621/1/UBC_1962_A7+R3+S4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Size effects in copper whiskers"],"dc:type":["Text"],"thesis:degree_discipline":["Mining Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:50:52Z"}