{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/39853"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/39853","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"An automatic dose plotter","abstract":"This thesis describes the design, operation, and performance of an automatic system which can be used to plot isodose curves such as are used in radiation therapy. The system consists of an apparatus to move an ionization chamber by remote control along rectangular axes so that the position of curves of equal per cent dose relative to any chosen reference point in the field are found and recorded automatically. The apparatus consists of a commerical servo system which operates from the output of an accurate dose comparator to control motion of the ionization chamber along one axis so that it hunts to locate the set per cent dose in the field to be plotted. A second manually-controlled drive system is used to provide a scan motion of the ionization chamber along the second axis. The drive systems are linked by two pairs of synchros to a plotting pen which records the path of the probe. The system is capable of producing an adequate set of isodose curves for a field in two hours or less with an accuracy of better than one-half per cent of the maximum dose in the field.","abstract_html":"This thesis describes the design, operation, and performance of an automatic system which can be used to plot isodose curves such as are used in radiation therapy. The system consists of an apparatus to move an ionization chamber by remote control along rectangular axes so that the position of curves of equal per cent dose relative to any chosen reference point in the field are found and recorded automatically. The apparatus consists of a commerical servo system which operates from the output of an accurate dose comparator to control motion of the ionization chamber along one axis so that it hunts to locate the set per cent dose in the field to be plotted. A second manually-controlled drive system is used to provide a scan motion of the ionization chamber along the second axis. The drive systems are linked by two pairs of synchros to a plotting pen which records the path of the probe. The system is capable of producing an adequate set of isodose curves for a field in two hours or less with an accuracy of better than one-half per cent of the maximum dose in the field.","abstract_has_math":false,"creators":["Hardy, William Lyle"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1961,"date_issued":"1961","date_published":"1961","updated_at":"2026-11-19T14:51:00Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/39853","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/39853","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/39853/1/UBC_1961_A6_7+H2+A9.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F39853","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hardy, William Lyle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1961"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/39853","http://circle.library.ubc.ca/bitstream/2429/39853/1/UBC_1961_A6_7+H2+A9.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis describes the design, operation, and performance of an automatic system which can be used to plot isodose curves such as are used in radiation therapy. The system consists of an apparatus to move an ionization chamber by remote control along rectangular axes so that the position of curves of equal per cent dose relative to any chosen reference point in the field are found and recorded automatically. The apparatus consists of a commerical servo system which operates from the output of an accurate dose comparator to control motion of the ionization chamber along one axis so that it hunts to locate the set per cent dose in the field to be plotted. A second manually-controlled drive system is used to provide a scan motion of the ionization chamber along the second axis. The drive systems are linked by two pairs of synchros to a plotting pen which records the path of the probe. The system is capable of producing an adequate set of isodose curves for a field in two hours or less with an accuracy of better than one-half per cent of the maximum dose in the field."]},{"key":"dc:format","label":"Dc Format","values":["3264220","application/pdf"]},{"key":"dc:title","label":"Title","values":["An automatic dose plotter"]}]}],"canonical_facts":{"dc:creator":["Hardy, William Lyle"],"dc:date":["1961"],"dc:description":["This thesis describes the design, operation, and performance of an automatic system which can be used to plot isodose curves such as are used in radiation therapy. The system consists of an apparatus to move an ionization chamber by remote control along rectangular axes so that the position of curves of equal per cent dose relative to any chosen reference point in the field are found and recorded automatically. The apparatus consists of a commerical servo system which operates from the output of an accurate dose comparator to control motion of the ionization chamber along one axis so that it hunts to locate the set per cent dose in the field to be plotted. A second manually-controlled drive system is used to provide a scan motion of the ionization chamber along the second axis. The drive systems are linked by two pairs of synchros to a plotting pen which records the path of the probe. The system is capable of producing an adequate set of isodose curves for a field in two hours or less with an accuracy of better than one-half per cent of the maximum dose in the field."],"dc:format":["3264220","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/39853","http://circle.library.ubc.ca/bitstream/2429/39853/1/UBC_1961_A6_7+H2+A9.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["An automatic dose plotter"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:00Z"}