{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/40151"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/40151","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Factors affecting the efficiency of a wet type dust collector","abstract":"Performance tests on a wet type dust collector were made using four different test dusts to determine a relationship between dust collection efficiency, particle size and size-distribution., collector nozzle velocity, and collector geometry. Dust laden air entered the collector and impinged upon a water surface at nozzle velocities in the order of 10,000 fpm. The fraction of dust which penetrated the collector was found to fit the equation [formula omitted] π = collector penetration (100% minus efficiency) ø[subscript]g = Geometric Coefficient of Variation of the test dust [formula omitted] V = collector nozzle velocity in thousands of fpm j = [formula omitted] π was found to vary from 0.121 percent with Corundum dust to 8.68 percent with Alundum dust. The nozzle velocity range was from6840 fpm to 14,130 fpm and the range of J was from 6.85 to 27.4. Corundum dust was found to have a value of ø[subscript]g equal to 0.123 with a geometric mean diamter, [formula omitted] , of 11.9 microns while ø[subscript]g and [formula omitted] for Alundum were calculated to be 0.521 and 4.84 microns respectively. The four test dusts were sized by a sedimentation method. The Function equation fits the experimental results with an uncertainty of ± 12 percent.","abstract_html":"Performance tests on a wet type dust collector were made using four different test dusts to determine a relationship between dust collection efficiency, particle size and size-distribution., collector nozzle velocity, and collector geometry. Dust laden air entered the collector and impinged upon a water surface at nozzle velocities in the order of 10,000 fpm. The fraction of dust which penetrated the collector was found to fit the equation [formula omitted] π = collector penetration (100% minus efficiency) ø[subscript]g = Geometric Coefficient of Variation of the test dust [formula omitted] V = collector nozzle velocity in thousands of fpm j = [formula omitted] π was found to vary from 0.121 percent with Corundum dust to 8.68 percent with Alundum dust. The nozzle velocity range was from6840 fpm to 14,130 fpm and the range of J was from 6.85 to 27.4. Corundum dust was found to have a value of ø[subscript]g equal to 0.123 with a geometric mean diamter, [formula omitted] , of 11.9 microns while ø[subscript]g and [formula omitted] for Alundum were calculated to be 0.521 and 4.84 microns respectively. The four test dusts were sized by a sedimentation method. The Function equation fits the experimental results with an uncertainty of ± 12 percent.","abstract_has_math":false,"creators":["Stewart, Robert Earl"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1963,"date_issued":"1963","date_published":"1963","updated_at":"2026-11-19T14:51:09Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/40151","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/40151","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/40151/1/UBC_1963_A7+S7+F2.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F40151","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Stewart, Robert Earl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1963"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/40151","http://circle.library.ubc.ca/bitstream/2429/40151/1/UBC_1963_A7+S7+F2.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Performance tests on a wet type dust collector were made using four different test dusts to determine a relationship between dust collection efficiency, particle size and size-distribution., collector nozzle velocity, and collector geometry. Dust laden air entered the collector and impinged upon a water surface at nozzle velocities in the order of 10,000 fpm. The fraction of dust which penetrated the collector was found to fit the equation [formula omitted] π = collector penetration (100% minus efficiency) ø[subscript]g = Geometric Coefficient of Variation of the test dust [formula omitted] V = collector nozzle velocity in thousands of fpm j = [formula omitted] π was found to vary from 0.121 percent with Corundum dust to 8.68 percent with Alundum dust. The nozzle velocity range was from6840 fpm to 14,130 fpm and the range of J was from 6.85 to 27.4. Corundum dust was found to have a value of ø[subscript]g equal to 0.123 with a geometric mean diamter, [formula omitted] , of 11.9 microns while ø[subscript]g and [formula omitted] for Alundum were calculated to be 0.521 and 4.84 microns respectively. The four test dusts were sized by a sedimentation method. The Function equation fits the experimental results with an uncertainty of ± 12 percent."]},{"key":"dc:format","label":"Dc Format","values":["6860442","application/pdf"]},{"key":"dc:title","label":"Title","values":["Factors affecting the efficiency of a wet type dust collector"]}]}],"canonical_facts":{"dc:creator":["Stewart, Robert Earl"],"dc:date":["1963"],"dc:description":["Performance tests on a wet type dust collector were made using four different test dusts to determine a relationship between dust collection efficiency, particle size and size-distribution., collector nozzle velocity, and collector geometry. Dust laden air entered the collector and impinged upon a water surface at nozzle velocities in the order of 10,000 fpm. The fraction of dust which penetrated the collector was found to fit the equation [formula omitted] π = collector penetration (100% minus efficiency) ø[subscript]g = Geometric Coefficient of Variation of the test dust [formula omitted] V = collector nozzle velocity in thousands of fpm j = [formula omitted] π was found to vary from 0.121 percent with Corundum dust to 8.68 percent with Alundum dust. The nozzle velocity range was from6840 fpm to 14,130 fpm and the range of J was from 6.85 to 27.4. Corundum dust was found to have a value of ø[subscript]g equal to 0.123 with a geometric mean diamter, [formula omitted] , of 11.9 microns while ø[subscript]g and [formula omitted] for Alundum were calculated to be 0.521 and 4.84 microns respectively. The four test dusts were sized by a sedimentation method. The Function equation fits the experimental results with an uncertainty of ± 12 percent."],"dc:format":["6860442","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/40151","http://circle.library.ubc.ca/bitstream/2429/40151/1/UBC_1963_A7+S7+F2.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Factors affecting the efficiency of a wet type dust collector"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:09Z"}