{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/40806"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/40806","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Volumetric analysis of metals in glacial acetic acid.","abstract":"Recent work has demonstrated that certain metal salts of inorganic acids may easily be titrated with perchloric acid in glacial acetic acid. To test the accuracy of the method, a series of titrations was run on the acetates of twenty-three representative metals. The resulting curves show that accurate reproducible end points may be obtained for the acetates of the more electropositive metals, while those of aluminum, chromium and iron yield anomalous results. An explanation for this is offered. The acetates of tin, bismuth, antimony, uranium and copper are too weak to be determined by this method. Metals, oxides, or other more difficultly soluble compounds may be conveniently introduced into acetic acid solution by first dissolving in nitric acid (or in certain cases aqua regia), followed by the addition of sufficient acetic anhydride to react with all the water and decompose all the nitrate present. Quantitative analytical separations may be effected using such common reagents as oxalic, nitric, and tartaric acid, hydrogen iodide and hydrogen sulphide. They were used in analysing eleven metal mixtures, with accuracy comparable to the more lengthy gravimetric process often required in aqueous solution.","abstract_html":"Recent work has demonstrated that certain metal salts of inorganic acids may easily be titrated with perchloric acid in glacial acetic acid. To test the accuracy of the method, a series of titrations was run on the acetates of twenty-three representative metals. The resulting curves show that accurate reproducible end points may be obtained for the acetates of the more electropositive metals, while those of aluminum, chromium and iron yield anomalous results. An explanation for this is offered. The acetates of tin, bismuth, antimony, uranium and copper are too weak to be determined by this method. Metals, oxides, or other more difficultly soluble compounds may be conveniently introduced into acetic acid solution by first dissolving in nitric acid (or in certain cases aqua regia), followed by the addition of sufficient acetic anhydride to react with all the water and decompose all the nitrate present. Quantitative analytical separations may be effected using such common reagents as oxalic, nitric, and tartaric acid, hydrogen iodide and hydrogen sulphide. They were used in analysing eleven metal mixtures, with accuracy comparable to the more lengthy gravimetric process often required in aqueous solution.","abstract_has_math":false,"creators":["Casey, Allan Terence"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1953,"date_issued":"1953","date_published":"1953","updated_at":"2026-11-19T14:51:35Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/40806","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/40806","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/40806/1/UBC_1953_A6_7+C2+V6.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F40806","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Casey, Allan Terence"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1953"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/40806","http://circle.library.ubc.ca/bitstream/2429/40806/1/UBC_1953_A6_7+C2+V6.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Recent work has demonstrated that certain metal salts of inorganic acids may easily be titrated with perchloric acid in glacial acetic acid. To test the accuracy of the method, a series of titrations was run on the acetates of twenty-three representative metals. The resulting curves show that accurate reproducible end points may be obtained for the acetates of the more electropositive metals, while those of aluminum, chromium and iron yield anomalous results. An explanation for this is offered. The acetates of tin, bismuth, antimony, uranium and copper are too weak to be determined by this method. Metals, oxides, or other more difficultly soluble compounds may be conveniently introduced into acetic acid solution by first dissolving in nitric acid (or in certain cases aqua regia), followed by the addition of sufficient acetic anhydride to react with all the water and decompose all the nitrate present. Quantitative analytical separations may be effected using such common reagents as oxalic, nitric, and tartaric acid, hydrogen iodide and hydrogen sulphide. They were used in analysing eleven metal mixtures, with accuracy comparable to the more lengthy gravimetric process often required in aqueous solution."]},{"key":"dc:format","label":"Dc Format","values":["3640685","application/pdf"]},{"key":"dc:title","label":"Title","values":["Volumetric analysis of metals in glacial acetic acid."]}]}],"canonical_facts":{"dc:creator":["Casey, Allan Terence"],"dc:date":["1953"],"dc:description":["Recent work has demonstrated that certain metal salts of inorganic acids may easily be titrated with perchloric acid in glacial acetic acid. To test the accuracy of the method, a series of titrations was run on the acetates of twenty-three representative metals. The resulting curves show that accurate reproducible end points may be obtained for the acetates of the more electropositive metals, while those of aluminum, chromium and iron yield anomalous results. An explanation for this is offered. The acetates of tin, bismuth, antimony, uranium and copper are too weak to be determined by this method. Metals, oxides, or other more difficultly soluble compounds may be conveniently introduced into acetic acid solution by first dissolving in nitric acid (or in certain cases aqua regia), followed by the addition of sufficient acetic anhydride to react with all the water and decompose all the nitrate present. Quantitative analytical separations may be effected using such common reagents as oxalic, nitric, and tartaric acid, hydrogen iodide and hydrogen sulphide. They were used in analysing eleven metal mixtures, with accuracy comparable to the more lengthy gravimetric process often required in aqueous solution."],"dc:format":["3640685","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/40806","http://circle.library.ubc.ca/bitstream/2429/40806/1/UBC_1953_A6_7+C2+V6.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Volumetric analysis of metals in glacial acetic acid."],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:35Z"}