{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/40923"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/40923","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Liquid-liquid extraction in a spray column","abstract":"A study was made on the back mixing or circulation in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone in the 1.5-in. I.D. columns of three different heights. Considerable circulation in the continuous water phase was observed which resulted in the reduction of the driving force for mass transfer. A driving force correction factor, F(m), was obtained from the H.T.U. data using a simplified picture of behaviour at the interface. The height of the tower did not seem to have any effect on F(m). The overall H.T.U. values, obtained from the experimental profiles, were correlated with the flow rates. The end effect due to the agitation and coalescence of the drops at the interface was measured. This end effect was correlated with the overall capacity coefficients and the dispersed phase flow rates.","abstract_html":"A study was made on the back mixing or circulation in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone in the 1.5-in. I.D. columns of three different heights. Considerable circulation in the continuous water phase was observed which resulted in the reduction of the driving force for mass transfer. A driving force correction factor, F(m), was obtained from the H.T.U. data using a simplified picture of behaviour at the interface. The height of the tower did not seem to have any effect on F(m). The overall H.T.U. values, obtained from the experimental profiles, were correlated with the flow rates. The end effect due to the agitation and coalescence of the drops at the interface was measured. This end effect was correlated with the overall capacity coefficients and the dispersed phase flow rates.","abstract_has_math":false,"creators":["Rai Choudhury, Prosenjit"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1959,"date_issued":"1959","date_published":"1959","updated_at":"2026-11-19T14:51:37Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/40923","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/40923","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/40923/1/UBC_1959_A7+R3+L4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F40923","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rai Choudhury, Prosenjit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1959"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/40923","http://circle.library.ubc.ca/bitstream/2429/40923/1/UBC_1959_A7+R3+L4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A study was made on the back mixing or circulation in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone in the 1.5-in. I.D. columns of three different heights. Considerable circulation in the continuous water phase was observed which resulted in the reduction of the driving force for mass transfer. A driving force correction factor, F(m), was obtained from the H.T.U. data using a simplified picture of behaviour at the interface. The height of the tower did not seem to have any effect on F(m). The overall H.T.U. values, obtained from the experimental profiles, were correlated with the flow rates. The end effect due to the agitation and coalescence of the drops at the interface was measured. This end effect was correlated with the overall capacity coefficients and the dispersed phase flow rates."]},{"key":"dc:format","label":"Dc Format","values":["7300276","application/pdf"]},{"key":"dc:title","label":"Title","values":["Liquid-liquid extraction in a spray column"]}]}],"canonical_facts":{"dc:creator":["Rai Choudhury, Prosenjit"],"dc:date":["1959"],"dc:description":["A study was made on the back mixing or circulation in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone in the 1.5-in. I.D. columns of three different heights. Considerable circulation in the continuous water phase was observed which resulted in the reduction of the driving force for mass transfer. A driving force correction factor, F(m), was obtained from the H.T.U. data using a simplified picture of behaviour at the interface. The height of the tower did not seem to have any effect on F(m). The overall H.T.U. values, obtained from the experimental profiles, were correlated with the flow rates. The end effect due to the agitation and coalescence of the drops at the interface was measured. This end effect was correlated with the overall capacity coefficients and the dispersed phase flow rates."],"dc:format":["7300276","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/40923","http://circle.library.ubc.ca/bitstream/2429/40923/1/UBC_1959_A7+R3+L4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Liquid-liquid extraction in a spray column"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:37Z"}