{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/40969"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/40969","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"An analysis of the Fraser River tidal control","abstract":"The development of an automatic control system involves a consideration of the problems of the stability and response of such a system. The purpose of this thesis is to outline these problems as they appear in the automatic control of water level in a tidal basin model. A synopsis of general servomechanism theory is briefly outlined stressing three points (1) Design the system so that oscillatory conditions prevail. (2) Design the natural frequency well above the operating frequency. (3) Where necessary introduce stabilizing networks. The results obtained by tests revealed one thing; the introduction of external circuits had very little effect on the continuous operation of the tidal model. An examination of the theoretical analysis of the control system however brought out three reasons for limiting the value of the constant K₄. The constant K₄ corresponds to the moment of inertia of a mechanical system. The constant K₄ is related to the parameters of the system, which are the area of the basin, the length of the weirs, and the pump discharge.","abstract_html":"The development of an automatic control system involves a consideration of the problems of the stability and response of such a system. The purpose of this thesis is to outline these problems as they appear in the automatic control of water level in a tidal basin model. A synopsis of general servomechanism theory is briefly outlined stressing three points (1) Design the system so that oscillatory conditions prevail. (2) Design the natural frequency well above the operating frequency. (3) Where necessary introduce stabilizing networks. The results obtained by tests revealed one thing; the introduction of external circuits had very little effect on the continuous operation of the tidal model. An examination of the theoretical analysis of the control system however brought out three reasons for limiting the value of the constant K₄. The constant K₄ corresponds to the moment of inertia of a mechanical system. The constant K₄ is related to the parameters of the system, which are the area of the basin, the length of the weirs, and the pump discharge.","abstract_has_math":false,"creators":["Kay, Donald Hughie James"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1951,"date_issued":"1951","date_published":"1951","updated_at":"2026-11-19T14:51:37Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/40969","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/40969","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/40969/1/UBC_1951_A7+K2+A5.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F40969","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kay, Donald Hughie James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1951"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/40969","http://circle.library.ubc.ca/bitstream/2429/40969/1/UBC_1951_A7+K2+A5.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The development of an automatic control system involves a consideration of the problems of the stability and response of such a system. The purpose of this thesis is to outline these problems as they appear in the automatic control of water level in a tidal basin model. A synopsis of general servomechanism theory is briefly outlined stressing three points (1) Design the system so that oscillatory conditions prevail. (2) Design the natural frequency well above the operating frequency. (3) Where necessary introduce stabilizing networks. The results obtained by tests revealed one thing; the introduction of external circuits had very little effect on the continuous operation of the tidal model. An examination of the theoretical analysis of the control system however brought out three reasons for limiting the value of the constant K₄. The constant K₄ corresponds to the moment of inertia of a mechanical system. The constant K₄ is related to the parameters of the system, which are the area of the basin, the length of the weirs, and the pump discharge."]},{"key":"dc:format","label":"Dc Format","values":["4198576","application/pdf"]},{"key":"dc:title","label":"Title","values":["An analysis of the Fraser River tidal control"]}]}],"canonical_facts":{"dc:creator":["Kay, Donald Hughie James"],"dc:date":["1951"],"dc:description":["The development of an automatic control system involves a consideration of the problems of the stability and response of such a system. The purpose of this thesis is to outline these problems as they appear in the automatic control of water level in a tidal basin model. A synopsis of general servomechanism theory is briefly outlined stressing three points (1) Design the system so that oscillatory conditions prevail. (2) Design the natural frequency well above the operating frequency. (3) Where necessary introduce stabilizing networks. The results obtained by tests revealed one thing; the introduction of external circuits had very little effect on the continuous operation of the tidal model. An examination of the theoretical analysis of the control system however brought out three reasons for limiting the value of the constant K₄. The constant K₄ corresponds to the moment of inertia of a mechanical system. The constant K₄ is related to the parameters of the system, which are the area of the basin, the length of the weirs, and the pump discharge."],"dc:format":["4198576","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/40969","http://circle.library.ubc.ca/bitstream/2429/40969/1/UBC_1951_A7+K2+A5.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["An analysis of the Fraser River tidal control"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:37Z"}