{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/41009"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/41009","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Dissipation factor measurements of transformer oil","abstract":"The present methods of ascertaining the probable sludging of transformer oils are laborious. A simple test, comparable to that used in obtaining the dielectric strength, would be of considerable value in reducing test manpower, equipment and expense. Present investigators measure such properties as oxygen absorption, colour change, increase in acidity, carbon dioxide evolved, water formed, the power factor, and the lnterfacial-tension value. Numerous dielectric materials exhibit anomalous dispersions. The attendant rise in dissipation factor encountered at the points of dispersion is helpful in determining the amounts and types of polarization present. Transformer oils, although initially non-polar, are subject to oxidation. This oxidation produces materials of polar molecular structure which govern the power loss in alternating current electric fields. The problem is one of correlating such losses to the state of the oil under test. This thesis deals with the investigations carried out on the above problem. Absorption bands for transformer oils have been found. The present work describes the presence and location of such absorption bands, and illustrates how the dipolar state of the oil affects the position of the loss peaks.","abstract_html":"The present methods of ascertaining the probable sludging of transformer oils are laborious. A simple test, comparable to that used in obtaining the dielectric strength, would be of considerable value in reducing test manpower, equipment and expense. Present investigators measure such properties as oxygen absorption, colour change, increase in acidity, carbon dioxide evolved, water formed, the power factor, and the lnterfacial-tension value. Numerous dielectric materials exhibit anomalous dispersions. The attendant rise in dissipation factor encountered at the points of dispersion is helpful in determining the amounts and types of polarization present. Transformer oils, although initially non-polar, are subject to oxidation. This oxidation produces materials of polar molecular structure which govern the power loss in alternating current electric fields. The problem is one of correlating such losses to the state of the oil under test. This thesis deals with the investigations carried out on the above problem. Absorption bands for transformer oils have been found. The present work describes the presence and location of such absorption bands, and illustrates how the dipolar state of the oil affects the position of the loss peaks.","abstract_has_math":false,"creators":["Smith, Frank Edward"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1951,"date_issued":"1951","date_published":"1951","updated_at":"2026-11-19T14:51:37Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/41009","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/41009","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/41009/1/UBC_1951_A7+S6+D4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F41009","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Smith, Frank Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1951"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/41009","http://circle.library.ubc.ca/bitstream/2429/41009/1/UBC_1951_A7+S6+D4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The present methods of ascertaining the probable sludging of transformer oils are laborious. A simple test, comparable to that used in obtaining the dielectric strength, would be of considerable value in reducing test manpower, equipment and expense. Present investigators measure such properties as oxygen absorption, colour change, increase in acidity, carbon dioxide evolved, water formed, the power factor, and the lnterfacial-tension value. Numerous dielectric materials exhibit anomalous dispersions. The attendant rise in dissipation factor encountered at the points of dispersion is helpful in determining the amounts and types of polarization present. Transformer oils, although initially non-polar, are subject to oxidation. This oxidation produces materials of polar molecular structure which govern the power loss in alternating current electric fields. The problem is one of correlating such losses to the state of the oil under test. This thesis deals with the investigations carried out on the above problem. Absorption bands for transformer oils have been found. The present work describes the presence and location of such absorption bands, and illustrates how the dipolar state of the oil affects the position of the loss peaks."]},{"key":"dc:format","label":"Dc Format","values":["5682545","application/pdf"]},{"key":"dc:title","label":"Title","values":["Dissipation factor measurements of transformer oil"]}]}],"canonical_facts":{"dc:creator":["Smith, Frank Edward"],"dc:date":["1951"],"dc:description":["The present methods of ascertaining the probable sludging of transformer oils are laborious. A simple test, comparable to that used in obtaining the dielectric strength, would be of considerable value in reducing test manpower, equipment and expense. Present investigators measure such properties as oxygen absorption, colour change, increase in acidity, carbon dioxide evolved, water formed, the power factor, and the lnterfacial-tension value. Numerous dielectric materials exhibit anomalous dispersions. The attendant rise in dissipation factor encountered at the points of dispersion is helpful in determining the amounts and types of polarization present. Transformer oils, although initially non-polar, are subject to oxidation. This oxidation produces materials of polar molecular structure which govern the power loss in alternating current electric fields. The problem is one of correlating such losses to the state of the oil under test. This thesis deals with the investigations carried out on the above problem. Absorption bands for transformer oils have been found. The present work describes the presence and location of such absorption bands, and illustrates how the dipolar state of the oil affects the position of the loss peaks."],"dc:format":["5682545","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/41009","http://circle.library.ubc.ca/bitstream/2429/41009/1/UBC_1951_A7+S6+D4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Dissipation factor measurements of transformer oil"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:51:37Z"}