{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/4108"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/4108","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Radiative muon capture of oxygen, aluminum, silicon, titanium, zirconium, and silver","abstract":"The photon spectra from radiative muon capture (RMC) on oxygen, aluminum, silicon, titanium, zirconium, and silver have been measured for photon energies greater than 57 MeV using a cylindrical pair spectrometer at TRIUMF. Ratios of RMC to ordinary muon capture (OMC) and values of the weak induced pseudoscalar coupling constant (specifically, gp/gA) have been calculated using the observed photon spectra in conjunction with theoretical nuclear RMC models. Present discrepancies between different theoretical calculations mean that experimental values of gp cannot yet be used to make meaningful tests of the partially conserved axial current hypothesis (PCAC). However, trends in RMC/OMC and gp/gA with atomic number indicate an extreme sensitivity of RMC, and nuclear weak virtual pion currents in particular, to Pauli blocking. A future RMC experiment at TRIUMF with the nickel isotopes ⁵⁸Ni, ⁶⁰Ni, and ⁶²Ni will help to clarify the present theoretical situation. Results from RMC on H and ³He are forthcoming shortly from TRIUMF, and will provide direct tests of PCAC.","abstract_html":"The photon spectra from radiative muon capture (RMC) on oxygen, aluminum, silicon, titanium, zirconium, and silver have been measured for photon energies greater than 57 MeV using a cylindrical pair spectrometer at TRIUMF. Ratios of RMC to ordinary muon capture (OMC) and values of the weak induced pseudoscalar coupling constant (specifically, gp/gA) have been calculated using the observed photon spectra in conjunction with theoretical nuclear RMC models. Present discrepancies between different theoretical calculations mean that experimental values of gp cannot yet be used to make meaningful tests of the partially conserved axial current hypothesis (PCAC). However, trends in RMC/OMC and gp/gA with atomic number indicate an extreme sensitivity of RMC, and nuclear weak virtual pion currents in particular, to Pauli blocking. A future RMC experiment at TRIUMF with the nickel isotopes ⁵⁸Ni, ⁶⁰Ni, and ⁶²Ni will help to clarify the present theoretical situation. Results from RMC on H and ³He are forthcoming shortly from TRIUMF, and will provide direct tests of PCAC.","abstract_has_math":false,"creators":["Bergbusch, Paul C."],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-19T14:24:26Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/4108","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/4108","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/4108/1/ubc_1995-0657.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F4108","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bergbusch, Paul C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/4108","http://circle.library.ubc.ca/bitstream/2429/4108/1/ubc_1995-0657.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The photon spectra from radiative muon capture (RMC) on oxygen, aluminum, silicon, titanium, zirconium, and silver have been measured for photon energies greater than 57 MeV using a cylindrical pair spectrometer at TRIUMF. Ratios of RMC to ordinary muon capture (OMC) and values of the weak induced pseudoscalar coupling constant (specifically, gp/gA) have been calculated using the observed photon spectra in conjunction with theoretical nuclear RMC models. Present discrepancies between different theoretical calculations mean that experimental values of gp cannot yet be used to make meaningful tests of the partially conserved axial current hypothesis (PCAC). However, trends in RMC/OMC and gp/gA with atomic number indicate an extreme sensitivity of RMC, and nuclear weak virtual pion currents in particular, to Pauli blocking. A future RMC experiment at TRIUMF with the nickel isotopes ⁵⁸Ni, ⁶⁰Ni, and ⁶²Ni will help to clarify the present theoretical situation. Results from RMC on H and ³He are forthcoming shortly from TRIUMF, and will provide direct tests of PCAC."]},{"key":"dc:format","label":"Dc Format","values":["3646344","application/pdf"]},{"key":"dc:title","label":"Title","values":["Radiative muon capture of oxygen, aluminum, silicon, titanium, zirconium, and silver"]}]}],"canonical_facts":{"dc:creator":["Bergbusch, Paul C."],"dc:date":["1995"],"dc:description":["The photon spectra from radiative muon capture (RMC) on oxygen, aluminum, silicon, titanium, zirconium, and silver have been measured for photon energies greater than 57 MeV using a cylindrical pair spectrometer at TRIUMF. Ratios of RMC to ordinary muon capture (OMC) and values of the weak induced pseudoscalar coupling constant (specifically, gp/gA) have been calculated using the observed photon spectra in conjunction with theoretical nuclear RMC models. Present discrepancies between different theoretical calculations mean that experimental values of gp cannot yet be used to make meaningful tests of the partially conserved axial current hypothesis (PCAC). However, trends in RMC/OMC and gp/gA with atomic number indicate an extreme sensitivity of RMC, and nuclear weak virtual pion currents in particular, to Pauli blocking. A future RMC experiment at TRIUMF with the nickel isotopes ⁵⁸Ni, ⁶⁰Ni, and ⁶²Ni will help to clarify the present theoretical situation. Results from RMC on H and ³He are forthcoming shortly from TRIUMF, and will provide direct tests of PCAC."],"dc:format":["3646344","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/4108","http://circle.library.ubc.ca/bitstream/2429/4108/1/ubc_1995-0657.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Radiative muon capture of oxygen, aluminum, silicon, titanium, zirconium, and silver"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:24:26Z"}