{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/41794"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/41794","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Design and construction of a high-dispersion infra-red spectrograph","abstract":"Details are given of the design and construction of a single-beam, three-prism, infra-red spectrograph, to be used in the near infra-red region 0.7μ to 2.5μ for the purpose of examining fine structure in molecular bands in this region. The problems encountered and methods of solution are explained. Details are presented of the optical and mechanical design of the instrument. The radiant energy transmitted by the spectrograph falls on a PbS photoconducting cell after being chopped at 900 c.p.s. The resulting signal is amplified in a tuned amplifier and, after rectification, is recorded on a Brown recording potentiometer. Details of detector and amplifier are presented. The method of calibration is explained and the performance of the instrument in practice is assessed by consideration of typical spectra taken with the final assembly.","abstract_html":"Details are given of the design and construction of a single-beam, three-prism, infra-red spectrograph, to be used in the near infra-red region 0.7μ to 2.5μ for the purpose of examining fine structure in molecular bands in this region. The problems encountered and methods of solution are explained. Details are presented of the optical and mechanical design of the instrument. The radiant energy transmitted by the spectrograph falls on a PbS photoconducting cell after being chopped at 900 c.p.s. The resulting signal is amplified in a tuned amplifier and, after rectification, is recorded on a Brown recording potentiometer. Details of detector and amplifier are presented. The method of calibration is explained and the performance of the instrument in practice is assessed by consideration of typical spectra taken with the final assembly.","abstract_has_math":false,"creators":["Brealey, George Albert"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1951,"date_issued":"1951","date_published":"1951","updated_at":"2026-11-19T14:52:02Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/41794","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/41794","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/41794/1/UBC_1951_A7+B8+D4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F41794","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Brealey, George Albert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1951"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/41794","http://circle.library.ubc.ca/bitstream/2429/41794/1/UBC_1951_A7+B8+D4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Details are given of the design and construction of a single-beam, three-prism, infra-red spectrograph, to be used in the near infra-red region 0.7μ to 2.5μ for the purpose of examining fine structure in molecular bands in this region. The problems encountered and methods of solution are explained. Details are presented of the optical and mechanical design of the instrument. The radiant energy transmitted by the spectrograph falls on a PbS photoconducting cell after being chopped at 900 c.p.s. The resulting signal is amplified in a tuned amplifier and, after rectification, is recorded on a Brown recording potentiometer. Details of detector and amplifier are presented. The method of calibration is explained and the performance of the instrument in practice is assessed by consideration of typical spectra taken with the final assembly."]},{"key":"dc:format","label":"Dc Format","values":["9825950","application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and construction of a high-dispersion infra-red spectrograph"]}]}],"canonical_facts":{"dc:creator":["Brealey, George Albert"],"dc:date":["1951"],"dc:description":["Details are given of the design and construction of a single-beam, three-prism, infra-red spectrograph, to be used in the near infra-red region 0.7μ to 2.5μ for the purpose of examining fine structure in molecular bands in this region. The problems encountered and methods of solution are explained. Details are presented of the optical and mechanical design of the instrument. The radiant energy transmitted by the spectrograph falls on a PbS photoconducting cell after being chopped at 900 c.p.s. The resulting signal is amplified in a tuned amplifier and, after rectification, is recorded on a Brown recording potentiometer. Details of detector and amplifier are presented. The method of calibration is explained and the performance of the instrument in practice is assessed by consideration of typical spectra taken with the final assembly."],"dc:format":["9825950","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/41794","http://circle.library.ubc.ca/bitstream/2429/41794/1/UBC_1951_A7+B8+D4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Design and construction of a high-dispersion infra-red spectrograph"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:52:02Z"}