{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/4218"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/4218","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Investigating the dependence of proton T₁ relaxation on pore size, pore fluid salinity, and pore fluid pH in water-wet sand packs","abstract":"The dependence of the proton nuclear magnetic resonance parameter, T₁ on surface wettability, grain size, and pore fluid chemistry was investigated using laboratory prepared silica sand packs. A pulsed proton NMR spectrometer, with a proton Larmour frequency of 90 MHz, was used to obtain the T₁ relaxation data. Pore fluid T₁ data were found to be dependent on the surface wettability of the sand packs. An observed difference in T₁ of approximately 1 second was obtained between 100% water-wet and 100% oil-wet sand packs, when the pH of the pore fluid was neutral. This difference in T₁ between the water-wet and oil-wet samples when saturated with distilled water, was observed for a range of different pore sizes. T₁ relaxation time was found to depend on sand pack grain size in both the water-wet and oil-wet samples. This indicated the presence of surface relaxation in the samples. Calculated surface relaxivities produced average values of 1.2 x 10-₃ cm/s and 2.6 x lO-₄ cm/s for the water-wet and the oil-wet samples respectively. Pore fluid chemistry was found to affect T₁ relaxation measurements in water-wet and oil-wet sand packs. Experimental results indicated that although T₁ was unaffected by pore fluid salinity it was dependent on the pore fluid pH. Results showed that as pore fluid acidity increased, T₁ relaxation times decreased in both the water-wet and the oil-wet sand packs. This enhanced relaxation at lower pH's was attributed to increased pore fluid relaxation at the grain surfaces.","abstract_html":"The dependence of the proton nuclear magnetic resonance parameter, T₁ on surface wettability, grain size, and pore fluid chemistry was investigated using laboratory prepared silica sand packs. A pulsed proton NMR spectrometer, with a proton Larmour frequency of 90 MHz, was used to obtain the T₁ relaxation data. Pore fluid T₁ data were found to be dependent on the surface wettability of the sand packs. An observed difference in T₁ of approximately 1 second was obtained between 100% water-wet and 100% oil-wet sand packs, when the pH of the pore fluid was neutral. This difference in T₁ between the water-wet and oil-wet samples when saturated with distilled water, was observed for a range of different pore sizes. T₁ relaxation time was found to depend on sand pack grain size in both the water-wet and oil-wet samples. This indicated the presence of surface relaxation in the samples. Calculated surface relaxivities produced average values of 1.2 x 10-₃ cm/s and 2.6 x lO-₄ cm/s for the water-wet and the oil-wet samples respectively. Pore fluid chemistry was found to affect T₁ relaxation measurements in water-wet and oil-wet sand packs. Experimental results indicated that although T₁ was unaffected by pore fluid salinity it was dependent on the pore fluid pH. Results showed that as pore fluid acidity increased, T₁ relaxation times decreased in both the water-wet and the oil-wet sand packs. This enhanced relaxation at lower pH&#x27;s was attributed to increased pore fluid relaxation at the grain surfaces.","abstract_has_math":false,"creators":["Kanters, William Andrew"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Geological Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996","date_published":"1996","updated_at":"2026-11-19T14:24:28Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/4218","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/4218","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/4218/1/ubc_1996-0134.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F4218","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kanters, William Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1996"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Geological Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/4218","http://circle.library.ubc.ca/bitstream/2429/4218/1/ubc_1996-0134.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The dependence of the proton nuclear magnetic resonance parameter, T₁ on surface wettability, grain size, and pore fluid chemistry was investigated using laboratory prepared silica sand packs. A pulsed proton NMR spectrometer, with a proton Larmour frequency of 90 MHz, was used to obtain the T₁ relaxation data. Pore fluid T₁ data were found to be dependent on the surface wettability of the sand packs. An observed difference in T₁ of approximately 1 second was obtained between 100% water-wet and 100% oil-wet sand packs, when the pH of the pore fluid was neutral. This difference in T₁ between the water-wet and oil-wet samples when saturated with distilled water, was observed for a range of different pore sizes. T₁ relaxation time was found to depend on sand pack grain size in both the water-wet and oil-wet samples. This indicated the presence of surface relaxation in the samples. Calculated surface relaxivities produced average values of 1.2 x 10-₃ cm/s and 2.6 x lO-₄ cm/s for the water-wet and the oil-wet samples respectively. Pore fluid chemistry was found to affect T₁ relaxation measurements in water-wet and oil-wet sand packs. Experimental results indicated that although T₁ was unaffected by pore fluid salinity it was dependent on the pore fluid pH. Results showed that as pore fluid acidity increased, T₁ relaxation times decreased in both the water-wet and the oil-wet sand packs. This enhanced relaxation at lower pH's was attributed to increased pore fluid relaxation at the grain surfaces."]},{"key":"dc:format","label":"Dc Format","values":["4875811","application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigating the dependence of proton T₁ relaxation on pore size, pore fluid salinity, and pore fluid pH in water-wet sand packs"]}]}],"canonical_facts":{"dc:creator":["Kanters, William Andrew"],"dc:date":["1996"],"dc:description":["The dependence of the proton nuclear magnetic resonance parameter, T₁ on surface wettability, grain size, and pore fluid chemistry was investigated using laboratory prepared silica sand packs. A pulsed proton NMR spectrometer, with a proton Larmour frequency of 90 MHz, was used to obtain the T₁ relaxation data. Pore fluid T₁ data were found to be dependent on the surface wettability of the sand packs. An observed difference in T₁ of approximately 1 second was obtained between 100% water-wet and 100% oil-wet sand packs, when the pH of the pore fluid was neutral. This difference in T₁ between the water-wet and oil-wet samples when saturated with distilled water, was observed for a range of different pore sizes. T₁ relaxation time was found to depend on sand pack grain size in both the water-wet and oil-wet samples. This indicated the presence of surface relaxation in the samples. Calculated surface relaxivities produced average values of 1.2 x 10-₃ cm/s and 2.6 x lO-₄ cm/s for the water-wet and the oil-wet samples respectively. Pore fluid chemistry was found to affect T₁ relaxation measurements in water-wet and oil-wet sand packs. Experimental results indicated that although T₁ was unaffected by pore fluid salinity it was dependent on the pore fluid pH. Results showed that as pore fluid acidity increased, T₁ relaxation times decreased in both the water-wet and the oil-wet sand packs. This enhanced relaxation at lower pH's was attributed to increased pore fluid relaxation at the grain surfaces."],"dc:format":["4875811","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/4218","http://circle.library.ubc.ca/bitstream/2429/4218/1/ubc_1996-0134.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Investigating the dependence of proton T₁ relaxation on pore size, pore fluid salinity, and pore fluid pH in water-wet sand packs"],"dc:type":["Text"],"thesis:degree_discipline":["Geological Sciences"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:24:28Z"}