{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/4352"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/4352","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The spatial filtering from core-scale conductivity to the conductivity measured by a slug test","abstract":"In the thesis, I investigate the measurement process of the slug test, an important and efficient engineering technique employed to probe aquifer properties. The objective is to determine the scale at which a slug test 'measures' hydraulic conductivity. To determine the scale, I conceptualize slug test measurement process in a system and filtering framework. I quantify, through numeric experiments, the spatial filtering effect of the slug test upon the core-scale hydraulic conductivity field. I examine the role of specific storage on this filtering effect. I develop two approaches to identify the system filter that epitomizes the filtering system — measurement process: spectral analysis with Wiener filtering and numerical perturbation. In heterogeneous media, system linearity is analyzed and the inverse estimation of the system output is evaluated. With the spectral approach, I optimally estimate the system filter in the presence of measurement noise. In homogeneous media where the spectral approach cannot be used, I apply the numerical perturbation approach. The spectral analysis and numerical perturbation are two conceptually different but complementary approaches. I analyze the nonparametric form of the system filter in heterogeneous media of various spatial variability and specific storage values. I determine the empirical parametric expression of equivalent filter width versus specific storage in homogeneous media. It is found that: 1. In both heterogeneous and homogeneous media, the equivalent filter width increases linearly with respect to log [mathematical formula which cannot be reproduced here; see pdf] 2. In homogeneous media, the filter amplitude decreases away from the wellbore by an approximate [mathematical formula which cannot be reproduced here; see pdf]. 3. A preliminary analysis of the role of heterogeneity characteristics upon the slugtest filtering was undertaken. The slug-test filtering was not strongly influenced by heterogeneity characteristics for log-conductivity variances less than 0.7. At variances less than 0.3, anisotropy in the conductivity field caused anisotropy in the slug-test filtering. These effects were not quantified in this thesis. In the end, I discuss the possible engineering and theoretical applications of the spatial filtering approach and make recommendations for future work.","abstract_html":"In the thesis, I investigate the measurement process of the slug test, an important and efficient engineering technique employed to probe aquifer properties. The objective is to determine the scale at which a slug test &#x27;measures&#x27; hydraulic conductivity. To determine the scale, I conceptualize slug test measurement process in a system and filtering framework. I quantify, through numeric experiments, the spatial filtering effect of the slug test upon the core-scale hydraulic conductivity field. I examine the role of specific storage on this filtering effect. I develop two approaches to identify the system filter that epitomizes the filtering system — measurement process: spectral analysis with Wiener filtering and numerical perturbation. In heterogeneous media, system linearity is analyzed and the inverse estimation of the system output is evaluated. With the spectral approach, I optimally estimate the system filter in the presence of measurement noise. In homogeneous media where the spectral approach cannot be used, I apply the numerical perturbation approach. The spectral analysis and numerical perturbation are two conceptually different but complementary approaches. I analyze the nonparametric form of the system filter in heterogeneous media of various spatial variability and specific storage values. I determine the empirical parametric expression of equivalent filter width versus specific storage in homogeneous media. It is found that: 1. In both heterogeneous and homogeneous media, the equivalent filter width increases linearly with respect to log [mathematical formula which cannot be reproduced here; see pdf] 2. In homogeneous media, the filter amplitude decreases away from the wellbore by an approximate [mathematical formula which cannot be reproduced here; see pdf]. 3. A preliminary analysis of the role of heterogeneity characteristics upon the slugtest filtering was undertaken. The slug-test filtering was not strongly influenced by heterogeneity characteristics for log-conductivity variances less than 0.7. At variances less than 0.3, anisotropy in the conductivity field caused anisotropy in the slug-test filtering. These effects were not quantified in this thesis. In the end, I discuss the possible engineering and theoretical applications of the spatial filtering approach and make recommendations for future work.","abstract_has_math":false,"creators":["Wang, Bin"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Geological Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-19T14:24:53Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/4352","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/4352","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/4352/1/ubc_1995-0528.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F4352","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wang, Bin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Geological Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/4352","http://circle.library.ubc.ca/bitstream/2429/4352/1/ubc_1995-0528.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the thesis, I investigate the measurement process of the slug test, an important and efficient engineering technique employed to probe aquifer properties. The objective is to determine the scale at which a slug test 'measures' hydraulic conductivity. To determine the scale, I conceptualize slug test measurement process in a system and filtering framework. I quantify, through numeric experiments, the spatial filtering effect of the slug test upon the core-scale hydraulic conductivity field. I examine the role of specific storage on this filtering effect. I develop two approaches to identify the system filter that epitomizes the filtering system — measurement process: spectral analysis with Wiener filtering and numerical perturbation. In heterogeneous media, system linearity is analyzed and the inverse estimation of the system output is evaluated. With the spectral approach, I optimally estimate the system filter in the presence of measurement noise. In homogeneous media where the spectral approach cannot be used, I apply the numerical perturbation approach. The spectral analysis and numerical perturbation are two conceptually different but complementary approaches. I analyze the nonparametric form of the system filter in heterogeneous media of various spatial variability and specific storage values. I determine the empirical parametric expression of equivalent filter width versus specific storage in homogeneous media. It is found that: 1. In both heterogeneous and homogeneous media, the equivalent filter width increases linearly with respect to log [mathematical formula which cannot be reproduced here; see pdf] 2. In homogeneous media, the filter amplitude decreases away from the wellbore by an approximate [mathematical formula which cannot be reproduced here; see pdf]. 3. A preliminary analysis of the role of heterogeneity characteristics upon the slugtest filtering was undertaken. The slug-test filtering was not strongly influenced by heterogeneity characteristics for log-conductivity variances less than 0.7. At variances less than 0.3, anisotropy in the conductivity field caused anisotropy in the slug-test filtering. These effects were not quantified in this thesis. In the end, I discuss the possible engineering and theoretical applications of the spatial filtering approach and make recommendations for future work."]},{"key":"dc:format","label":"Dc Format","values":["14237754","application/pdf"]},{"key":"dc:title","label":"Title","values":["The spatial filtering from core-scale conductivity to the conductivity measured by a slug test"]}]}],"canonical_facts":{"dc:creator":["Wang, Bin"],"dc:date":["1995"],"dc:description":["In the thesis, I investigate the measurement process of the slug test, an important and efficient engineering technique employed to probe aquifer properties. The objective is to determine the scale at which a slug test 'measures' hydraulic conductivity. To determine the scale, I conceptualize slug test measurement process in a system and filtering framework. I quantify, through numeric experiments, the spatial filtering effect of the slug test upon the core-scale hydraulic conductivity field. I examine the role of specific storage on this filtering effect. I develop two approaches to identify the system filter that epitomizes the filtering system — measurement process: spectral analysis with Wiener filtering and numerical perturbation. In heterogeneous media, system linearity is analyzed and the inverse estimation of the system output is evaluated. With the spectral approach, I optimally estimate the system filter in the presence of measurement noise. In homogeneous media where the spectral approach cannot be used, I apply the numerical perturbation approach. The spectral analysis and numerical perturbation are two conceptually different but complementary approaches. I analyze the nonparametric form of the system filter in heterogeneous media of various spatial variability and specific storage values. I determine the empirical parametric expression of equivalent filter width versus specific storage in homogeneous media. It is found that: 1. In both heterogeneous and homogeneous media, the equivalent filter width increases linearly with respect to log [mathematical formula which cannot be reproduced here; see pdf] 2. In homogeneous media, the filter amplitude decreases away from the wellbore by an approximate [mathematical formula which cannot be reproduced here; see pdf]. 3. A preliminary analysis of the role of heterogeneity characteristics upon the slugtest filtering was undertaken. The slug-test filtering was not strongly influenced by heterogeneity characteristics for log-conductivity variances less than 0.7. At variances less than 0.3, anisotropy in the conductivity field caused anisotropy in the slug-test filtering. These effects were not quantified in this thesis. In the end, I discuss the possible engineering and theoretical applications of the spatial filtering approach and make recommendations for future work."],"dc:format":["14237754","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/4352","http://circle.library.ubc.ca/bitstream/2429/4352/1/ubc_1995-0528.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The spatial filtering from core-scale conductivity to the conductivity measured by a slug test"],"dc:type":["Text"],"thesis:degree_discipline":["Geological Sciences"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:24:53Z"}