{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/50469"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/50469","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"On the design of high-voltage analog front-end circuits for capacitive micromachined ultrasonic transducers (CMUT)","abstract":"In ultrasound imaging, capacitive micromachined ultrasonic transducer (CMUT) technology has become a promising alternative to conventional piezoelectric- based technology. This work focuses on various aspects of CMUT-based imaging technologies. In the context of CMUT design and integration with associated electronics, flexible and reliable CMUT models that can be seamlessly simulated with the read-out circuits and provide insights in the system-level performance are of great importance. This work proposes a generic Verilog-AMS model for CMUT sensors that takes into account the non-linearities, dynamic behavior and harmonic resonances of the CMUT. This model is able to provide reliable estimations of the pull-in voltage as well as the resonance frequency and the spring softening effect. To improve the signal-to-noise ratio (SNR), integrating the CMUT transducer with the front-end electronics is critical. Design and implementation of a comprehensive analog front-end system in a 0.8μm high-voltage CMOS technology which includes high-voltage and fast-switching transmitters as well as low-power variable-gain receivers is presented. Co-simulation of the front-end electronics and the CMUT model demonstrates full system functionality. Experimental results of the system at the transmit mode confirm the reliability of this co-simulation. An on-chip adaptive biasing unit (ABU) is also included in the design which aims to improve the CMUT receive sensitivity. The ABU consists of a DC-DC converter to generate a range of bias voltage levels and a digital control unit to select the desired voltage. Co- simulation of the ABU with the Verilog-AMS model confirms the increase in the CMUT sensitivity in receive mode. In the context of CMUT super-resolution imaging, we present the design of a transceiver circuit in a 0.35μm high-voltage CMOS technology that supports both the fundamental and asymmetric modes of operation. The transmitter provides high- voltage pulses to the CMUT electrodes. The receiver includes transimpedance analog adders to add the fundamental mode in-phase signals as well as differential amplifiers to combine the out-of-phase signals of the asymmetric modes. Furthermore, low- power variable-gain stages are included to amplify the resulting signals and facilitate interfacing to the ultrasound imaging machine for additional processing and display. The design functionality is confirmed by experimental results.","abstract_html":"In ultrasound imaging, capacitive micromachined ultrasonic transducer (CMUT) technology has become a promising alternative to conventional piezoelectric- based technology. This work focuses on various aspects of CMUT-based imaging technologies. In the context of CMUT design and integration with associated electronics, flexible and reliable CMUT models that can be seamlessly simulated with the read-out circuits and provide insights in the system-level performance are of great importance. This work proposes a generic Verilog-AMS model for CMUT sensors that takes into account the non-linearities, dynamic behavior and harmonic resonances of the CMUT. This model is able to provide reliable estimations of the pull-in voltage as well as the resonance frequency and the spring softening effect. To improve the signal-to-noise ratio (SNR), integrating the CMUT transducer with the front-end electronics is critical. Design and implementation of a comprehensive analog front-end system in a 0.8μm high-voltage CMOS technology which includes high-voltage and fast-switching transmitters as well as low-power variable-gain receivers is presented. Co-simulation of the front-end electronics and the CMUT model demonstrates full system functionality. Experimental results of the system at the transmit mode confirm the reliability of this co-simulation. An on-chip adaptive biasing unit (ABU) is also included in the design which aims to improve the CMUT receive sensitivity. The ABU consists of a DC-DC converter to generate a range of bias voltage levels and a digital control unit to select the desired voltage. Co- simulation of the ABU with the Verilog-AMS model confirms the increase in the CMUT sensitivity in receive mode. In the context of CMUT super-resolution imaging, we present the design of a transceiver circuit in a 0.35μm high-voltage CMOS technology that supports both the fundamental and asymmetric modes of operation. The transmitter provides high- voltage pulses to the CMUT electrodes. The receiver includes transimpedance analog adders to add the fundamental mode in-phase signals as well as differential amplifiers to combine the out-of-phase signals of the asymmetric modes. Furthermore, low- power variable-gain stages are included to amplify the resulting signals and facilitate interfacing to the ultrasound imaging machine for additional processing and display. The design functionality is confirmed by experimental results.","abstract_has_math":false,"creators":["Behnamfar, Parisa"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T14:58:45Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/50469","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/50469","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/50469/1/ubc_2014_november_behnamfar_parisa.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F50469","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Behnamfar, Parisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/50469","http://circle.library.ubc.ca/bitstream/2429/50469/1/ubc_2014_november_behnamfar_parisa.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In ultrasound imaging, capacitive micromachined ultrasonic transducer (CMUT) technology has become a promising alternative to conventional piezoelectric- based technology. This work focuses on various aspects of CMUT-based imaging technologies. In the context of CMUT design and integration with associated electronics, flexible and reliable CMUT models that can be seamlessly simulated with the read-out circuits and provide insights in the system-level performance are of great importance. This work proposes a generic Verilog-AMS model for CMUT sensors that takes into account the non-linearities, dynamic behavior and harmonic resonances of the CMUT. This model is able to provide reliable estimations of the pull-in voltage as well as the resonance frequency and the spring softening effect. To improve the signal-to-noise ratio (SNR), integrating the CMUT transducer with the front-end electronics is critical. Design and implementation of a comprehensive analog front-end system in a 0.8μm high-voltage CMOS technology which includes high-voltage and fast-switching transmitters as well as low-power variable-gain receivers is presented. Co-simulation of the front-end electronics and the CMUT model demonstrates full system functionality. Experimental results of the system at the transmit mode confirm the reliability of this co-simulation. An on-chip adaptive biasing unit (ABU) is also included in the design which aims to improve the CMUT receive sensitivity. The ABU consists of a DC-DC converter to generate a range of bias voltage levels and a digital control unit to select the desired voltage. Co- simulation of the ABU with the Verilog-AMS model confirms the increase in the CMUT sensitivity in receive mode. In the context of CMUT super-resolution imaging, we present the design of a transceiver circuit in a 0.35μm high-voltage CMOS technology that supports both the fundamental and asymmetric modes of operation. The transmitter provides high- voltage pulses to the CMUT electrodes. The receiver includes transimpedance analog adders to add the fundamental mode in-phase signals as well as differential amplifiers to combine the out-of-phase signals of the asymmetric modes. Furthermore, low- power variable-gain stages are included to amplify the resulting signals and facilitate interfacing to the ultrasound imaging machine for additional processing and display. The design functionality is confirmed by experimental results."]},{"key":"dc:format","label":"Dc Format","values":["17109388","application/pdf"]},{"key":"dc:title","label":"Title","values":["On the design of high-voltage analog front-end circuits for capacitive micromachined ultrasonic transducers (CMUT)"]}]}],"canonical_facts":{"dc:creator":["Behnamfar, Parisa"],"dc:date":["2014"],"dc:description":["In ultrasound imaging, capacitive micromachined ultrasonic transducer (CMUT) technology has become a promising alternative to conventional piezoelectric- based technology. This work focuses on various aspects of CMUT-based imaging technologies. In the context of CMUT design and integration with associated electronics, flexible and reliable CMUT models that can be seamlessly simulated with the read-out circuits and provide insights in the system-level performance are of great importance. This work proposes a generic Verilog-AMS model for CMUT sensors that takes into account the non-linearities, dynamic behavior and harmonic resonances of the CMUT. This model is able to provide reliable estimations of the pull-in voltage as well as the resonance frequency and the spring softening effect. To improve the signal-to-noise ratio (SNR), integrating the CMUT transducer with the front-end electronics is critical. Design and implementation of a comprehensive analog front-end system in a 0.8μm high-voltage CMOS technology which includes high-voltage and fast-switching transmitters as well as low-power variable-gain receivers is presented. Co-simulation of the front-end electronics and the CMUT model demonstrates full system functionality. Experimental results of the system at the transmit mode confirm the reliability of this co-simulation. An on-chip adaptive biasing unit (ABU) is also included in the design which aims to improve the CMUT receive sensitivity. The ABU consists of a DC-DC converter to generate a range of bias voltage levels and a digital control unit to select the desired voltage. Co- simulation of the ABU with the Verilog-AMS model confirms the increase in the CMUT sensitivity in receive mode. In the context of CMUT super-resolution imaging, we present the design of a transceiver circuit in a 0.35μm high-voltage CMOS technology that supports both the fundamental and asymmetric modes of operation. The transmitter provides high- voltage pulses to the CMUT electrodes. The receiver includes transimpedance analog adders to add the fundamental mode in-phase signals as well as differential amplifiers to combine the out-of-phase signals of the asymmetric modes. Furthermore, low- power variable-gain stages are included to amplify the resulting signals and facilitate interfacing to the ultrasound imaging machine for additional processing and display. The design functionality is confirmed by experimental results."],"dc:format":["17109388","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/50469","http://circle.library.ubc.ca/bitstream/2429/50469/1/ubc_2014_november_behnamfar_parisa.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:title":["On the design of high-voltage analog front-end circuits for capacitive micromachined ultrasonic transducers (CMUT)"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:58:45Z"}