{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/51779"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/51779","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Selective and regulated RF heating of stent toward endohyperthermia treatment of in-stent restenosis","abstract":"This thesis presents a novel active stent system with a selective radio frequency (RF)heating and temperature regulation capabilities. Such system is targeted at the application to endohyperthermia treatment for in-stent restenosis problems, providing a cheap and non-invasive long-term solution to the blood vessel blockage caused by a growth of scar tissue across the stent structure after implantation. The research work consists of two major portions. Firstly, a novel active stent device with ability of selective RF heating has been custom designed and explored. The device is formed by integrating a stainless-steel based stent with a flexible capacitor strip, which serves as a frequency-selective wireless heater controlled using a tuned RF electromagnetic field applied externally. The proof-of-concept prototype device has been developed based on micro-electromechanical systems (MEMS) fabrication processes; its electrical and thermal characteristics are studied thoroughly. The finalized device is tested and evaluated within an artificial artery for validating its potential feasibility of wireless stent hyperthermia.Secondly, a MEMS-based, thermally sensitive circuit breaker chip has been designed and fabricated for the active stent temperature regulation. The temperature of an active stent device can be managed within a certain range after integrated with the chip, offering the controllability of RF heating of the device. Customized design and packaging methods are used in the chip fabrication; the chip-stent integration technique is also explored. The finalized device is evaluated with in-vitro tests, showing its temporal capability and wireless reliability. The experiment result verifies device working principles and suggests a direction of future research on non-invasive endohyperthermia treatments for long-term restenosis management.","abstract_html":"This thesis presents a novel active stent system with a selective radio frequency (RF)heating and temperature regulation capabilities. Such system is targeted at the application to endohyperthermia treatment for in-stent restenosis problems, providing a cheap and non-invasive long-term solution to the blood vessel blockage caused by a growth of scar tissue across the stent structure after implantation. The research work consists of two major portions. Firstly, a novel active stent device with ability of selective RF heating has been custom designed and explored. The device is formed by integrating a stainless-steel based stent with a flexible capacitor strip, which serves as a frequency-selective wireless heater controlled using a tuned RF electromagnetic field applied externally. The proof-of-concept prototype device has been developed based on micro-electromechanical systems (MEMS) fabrication processes; its electrical and thermal characteristics are studied thoroughly. The finalized device is tested and evaluated within an artificial artery for validating its potential feasibility of wireless stent hyperthermia.Secondly, a MEMS-based, thermally sensitive circuit breaker chip has been designed and fabricated for the active stent temperature regulation. The temperature of an active stent device can be managed within a certain range after integrated with the chip, offering the controllability of RF heating of the device. Customized design and packaging methods are used in the chip fabrication; the chip-stent integration technique is also explored. The finalized device is evaluated with in-vitro tests, showing its temporal capability and wireless reliability. The experiment result verifies device working principles and suggests a direction of future research on non-invasive endohyperthermia treatments for long-term restenosis management.","abstract_has_math":false,"creators":["Luo, Yi"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T14:59:09Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/51779","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/51779","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/51779/4/ubc_2015_february_luo_yi.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F51779","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Luo, Yi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/51779","http://circle.library.ubc.ca/bitstream/2429/51779/4/ubc_2015_february_luo_yi.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis presents a novel active stent system with a selective radio frequency (RF)heating and temperature regulation capabilities. Such system is targeted at the application to endohyperthermia treatment for in-stent restenosis problems, providing a cheap and non-invasive long-term solution to the blood vessel blockage caused by a growth of scar tissue across the stent structure after implantation. The research work consists of two major portions. Firstly, a novel active stent device with ability of selective RF heating has been custom designed and explored. The device is formed by integrating a stainless-steel based stent with a flexible capacitor strip, which serves as a frequency-selective wireless heater controlled using a tuned RF electromagnetic field applied externally. The proof-of-concept prototype device has been developed based on micro-electromechanical systems (MEMS) fabrication processes; its electrical and thermal characteristics are studied thoroughly. The finalized device is tested and evaluated within an artificial artery for validating its potential feasibility of wireless stent hyperthermia.Secondly, a MEMS-based, thermally sensitive circuit breaker chip has been designed and fabricated for the active stent temperature regulation. The temperature of an active stent device can be managed within a certain range after integrated with the chip, offering the controllability of RF heating of the device. Customized design and packaging methods are used in the chip fabrication; the chip-stent integration technique is also explored. The finalized device is evaluated with in-vitro tests, showing its temporal capability and wireless reliability. The experiment result verifies device working principles and suggests a direction of future research on non-invasive endohyperthermia treatments for long-term restenosis management."]},{"key":"dc:format","label":"Dc Format","values":["6329450","application/pdf"]},{"key":"dc:title","label":"Title","values":["Selective and regulated RF heating of stent toward endohyperthermia treatment of in-stent restenosis"]}]}],"canonical_facts":{"dc:creator":["Luo, Yi"],"dc:date":["2014"],"dc:description":["This thesis presents a novel active stent system with a selective radio frequency (RF)heating and temperature regulation capabilities. Such system is targeted at the application to endohyperthermia treatment for in-stent restenosis problems, providing a cheap and non-invasive long-term solution to the blood vessel blockage caused by a growth of scar tissue across the stent structure after implantation. The research work consists of two major portions. Firstly, a novel active stent device with ability of selective RF heating has been custom designed and explored. The device is formed by integrating a stainless-steel based stent with a flexible capacitor strip, which serves as a frequency-selective wireless heater controlled using a tuned RF electromagnetic field applied externally. The proof-of-concept prototype device has been developed based on micro-electromechanical systems (MEMS) fabrication processes; its electrical and thermal characteristics are studied thoroughly. The finalized device is tested and evaluated within an artificial artery for validating its potential feasibility of wireless stent hyperthermia.Secondly, a MEMS-based, thermally sensitive circuit breaker chip has been designed and fabricated for the active stent temperature regulation. The temperature of an active stent device can be managed within a certain range after integrated with the chip, offering the controllability of RF heating of the device. Customized design and packaging methods are used in the chip fabrication; the chip-stent integration technique is also explored. The finalized device is evaluated with in-vitro tests, showing its temporal capability and wireless reliability. The experiment result verifies device working principles and suggests a direction of future research on non-invasive endohyperthermia treatments for long-term restenosis management."],"dc:format":["6329450","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/51779","http://circle.library.ubc.ca/bitstream/2429/51779/4/ubc_2015_february_luo_yi.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:title":["Selective and regulated RF heating of stent toward endohyperthermia treatment of in-stent restenosis"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:59:09Z"}