{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/51990"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/51990","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Design of a radio frequency heating system for electrolytic liquids and sludges","abstract":"A radio frequency (RF) heating system has been designed to heat electrolytic liquids and sludges in a pressurized test vessel. The RF heating system is designed to heat a 400 ml load volume at a frequency of 13.56 MHz using a 1 kW RF generator. The primary application for the heating system is to conduct experimental work on the pretreatment of waste activated sludge, a byproduct of wastewater treatment plants. The dielectric properties of waste activated sludge were analyzed and it was determined that ionic conduction heating at a low frequency would be more efficient than microwave heating at a frequency of 2.45 GHz. The RF heating system was tested with sludge and salt water loads over a temperature range of 20°C to 120°C. Power transfer efficiency from the generator to the load was excellent and exceeded 86% over the entire temperature range for both loads. An important part of this work was the design of the RF applicator. The applicator consists of two circular electrodes mounted inside a Teflon cylinder to uniformly heat the load. The Teflon cylinder has seals and can heat loads under pressure. The load cylinder is enclosed in a coaxial housing and the geometry of the load cylinder and enclosure are designed to provide a nominal impedance of 50 Ω to match the RF generator impedance. The applicator has a thermocouple embedded in an electrode and a software control system is implemented in LabView to adjust the generator power for a target ramp rate or to maintain a steady state temperature. Extensive electromagnetic simulations were done to verify and optimize the applicator design. Analytic, simulation and experimental results are compared and very good agreement is obtained.","abstract_html":"A radio frequency (RF) heating system has been designed to heat electrolytic liquids and sludges in a pressurized test vessel. The RF heating system is designed to heat a 400 ml load volume at a frequency of 13.56 MHz using a 1 kW RF generator. The primary application for the heating system is to conduct experimental work on the pretreatment of waste activated sludge, a byproduct of wastewater treatment plants. The dielectric properties of waste activated sludge were analyzed and it was determined that ionic conduction heating at a low frequency would be more efficient than microwave heating at a frequency of 2.45 GHz. The RF heating system was tested with sludge and salt water loads over a temperature range of 20°C to 120°C. Power transfer efficiency from the generator to the load was excellent and exceeded 86% over the entire temperature range for both loads. An important part of this work was the design of the RF applicator. The applicator consists of two circular electrodes mounted inside a Teflon cylinder to uniformly heat the load. The Teflon cylinder has seals and can heat loads under pressure. The load cylinder is enclosed in a coaxial housing and the geometry of the load cylinder and enclosure are designed to provide a nominal impedance of 50 Ω to match the RF generator impedance. The applicator has a thermocouple embedded in an electrode and a software control system is implemented in LabView to adjust the generator power for a target ramp rate or to maintain a steady state temperature. Extensive electromagnetic simulations were done to verify and optimize the applicator design. Analytic, simulation and experimental results are compared and very good agreement is obtained.","abstract_has_math":false,"creators":["Ferdous, Md. Saimoom"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-19T14:59:16Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/51990","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/51990","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/51990/1/ubc_2015_february_ferdous_md.+saimoom.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F51990","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ferdous, Md. Saimoom"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/51990","http://circle.library.ubc.ca/bitstream/2429/51990/1/ubc_2015_february_ferdous_md.+saimoom.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A radio frequency (RF) heating system has been designed to heat electrolytic liquids and sludges in a pressurized test vessel. The RF heating system is designed to heat a 400 ml load volume at a frequency of 13.56 MHz using a 1 kW RF generator. The primary application for the heating system is to conduct experimental work on the pretreatment of waste activated sludge, a byproduct of wastewater treatment plants. The dielectric properties of waste activated sludge were analyzed and it was determined that ionic conduction heating at a low frequency would be more efficient than microwave heating at a frequency of 2.45 GHz. The RF heating system was tested with sludge and salt water loads over a temperature range of 20°C to 120°C. Power transfer efficiency from the generator to the load was excellent and exceeded 86% over the entire temperature range for both loads. An important part of this work was the design of the RF applicator. The applicator consists of two circular electrodes mounted inside a Teflon cylinder to uniformly heat the load. The Teflon cylinder has seals and can heat loads under pressure. The load cylinder is enclosed in a coaxial housing and the geometry of the load cylinder and enclosure are designed to provide a nominal impedance of 50 Ω to match the RF generator impedance. The applicator has a thermocouple embedded in an electrode and a software control system is implemented in LabView to adjust the generator power for a target ramp rate or to maintain a steady state temperature. Extensive electromagnetic simulations were done to verify and optimize the applicator design. Analytic, simulation and experimental results are compared and very good agreement is obtained."]},{"key":"dc:format","label":"Dc Format","values":["1861345","application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of a radio frequency heating system for electrolytic liquids and sludges"]}]}],"canonical_facts":{"dc:creator":["Ferdous, Md. Saimoom"],"dc:date":["2015"],"dc:description":["A radio frequency (RF) heating system has been designed to heat electrolytic liquids and sludges in a pressurized test vessel. The RF heating system is designed to heat a 400 ml load volume at a frequency of 13.56 MHz using a 1 kW RF generator. The primary application for the heating system is to conduct experimental work on the pretreatment of waste activated sludge, a byproduct of wastewater treatment plants. The dielectric properties of waste activated sludge were analyzed and it was determined that ionic conduction heating at a low frequency would be more efficient than microwave heating at a frequency of 2.45 GHz. The RF heating system was tested with sludge and salt water loads over a temperature range of 20°C to 120°C. Power transfer efficiency from the generator to the load was excellent and exceeded 86% over the entire temperature range for both loads. An important part of this work was the design of the RF applicator. The applicator consists of two circular electrodes mounted inside a Teflon cylinder to uniformly heat the load. The Teflon cylinder has seals and can heat loads under pressure. The load cylinder is enclosed in a coaxial housing and the geometry of the load cylinder and enclosure are designed to provide a nominal impedance of 50 Ω to match the RF generator impedance. The applicator has a thermocouple embedded in an electrode and a software control system is implemented in LabView to adjust the generator power for a target ramp rate or to maintain a steady state temperature. Extensive electromagnetic simulations were done to verify and optimize the applicator design. Analytic, simulation and experimental results are compared and very good agreement is obtained."],"dc:format":["1861345","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/51990","http://circle.library.ubc.ca/bitstream/2429/51990/1/ubc_2015_february_ferdous_md.+saimoom.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:title":["Design of a radio frequency heating system for electrolytic liquids and sludges"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:59:16Z"}