{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/53995"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/53995","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Restoration of endodontically treated immature teeth : influence of post fit on bonding properties of conventionally and adhesively luted fiber-reinforced composite posts","abstract":"Objective: To evaluate the influence of post fit and luting system on pull-out force and failure mode of conventionally and adhesively luted fiber-reinforced composite posts (FRCP). Methods: 260 extracted bovine deciduous teeth were randomly assigned to each of the four luting systems (Fuji Plus (FP), RelyX Unicem (RXU), Multilink Primer/Multilink (MLP_ML), LuxaBond/LuxaCore Z (LB_LCZ and three post fits (Congruency (C), medium incongruency (MIC), high incongruency (HIC)) (n=20/group). The teeth were decapitated, root canal treated, embedded and post space was prepared. The FRCPs (Macro-Lock Post sizes 1, 3 and 6) were pretreated and inserted, according to the manufacturer’s instructions. The custom-made titanium-post was inserted with Ketac Cem (control) (n=20). After water storage (24h, 37°C), pull-out test was performed. The data were analyzed using Kolmogorov-Smirnov test (p>0.05), Two-way ANOVA and post-hoc tests (Dunnett T3 with Bonferroni correction) (α=0.05). Failure mode was assessed using a stereomicroscope. Results: The influence of post fit and luting system was statistically significant (p<0.001), while the interaction of the two factors was not (p = 0.030). When comparing pull-out forces for the three post fits, significant differences (p < 0.017) were found between C (436.6±148.7 N) and MIC (426.0±102.1 N) and C and HIC (397.5±89.8 N). Failure mode was dominated by failure between dentin and luting system (64.2-70.7%) and between luting system and post (29.3-35.5%), for all post fit groups. Pairwise comparison revealed significant differences in pull-out force (p < 0.008) for all luting systems (FP: 441.2±44.9 N, RXU: 390.7±80.5 N, MLP_ML: 379.3±106.8 N, LB_LCZ: 544.0±96.6 N), except when comparing RXU and MLP_ML. Pull-out forces, achieved with all luting systems, were significantly higher compared to the control (211.2±35.1 N). The main failure for FP was found between luting system and post (92.3%) while main failure for RXU (99.5%), MLP_ML (95.8%), LB_LCZ (65.5%) was found between dentin and luting system. Conclusion: Post fit and luting system influenced the pull-out force of conventionally and adhesively luted FRCPs. Congruent post fit achieved the highest pull-out forces. The three-step Etch & Rinse adhesive luting system LB_LCZ generated considerably higher pull-out forces than all other tested luting systems.","abstract_html":"Objective: To evaluate the influence of post fit and luting system on pull-out force and failure mode of conventionally and adhesively luted fiber-reinforced composite posts (FRCP). Methods: 260 extracted bovine deciduous teeth were randomly assigned to each of the four luting systems (Fuji Plus (FP), RelyX Unicem (RXU), Multilink Primer/Multilink (MLP_ML), LuxaBond/LuxaCore Z (LB_LCZ and three post fits (Congruency (C), medium incongruency (MIC), high incongruency (HIC)) (n=20/group). The teeth were decapitated, root canal treated, embedded and post space was prepared. The FRCPs (Macro-Lock Post sizes 1, 3 and 6) were pretreated and inserted, according to the manufacturer’s instructions. The custom-made titanium-post was inserted with Ketac Cem (control) (n=20). After water storage (24h, 37°C), pull-out test was performed. The data were analyzed using Kolmogorov-Smirnov test (p&gt;0.05), Two-way ANOVA and post-hoc tests (Dunnett T3 with Bonferroni correction) (α=0.05). Failure mode was assessed using a stereomicroscope. Results: The influence of post fit and luting system was statistically significant (p&lt;0.001), while the interaction of the two factors was not (p = 0.030). When comparing pull-out forces for the three post fits, significant differences (p &lt; 0.017) were found between C (436.6±148.7 N) and MIC (426.0±102.1 N) and C and HIC (397.5±89.8 N). Failure mode was dominated by failure between dentin and luting system (64.2-70.7%) and between luting system and post (29.3-35.5%), for all post fit groups. Pairwise comparison revealed significant differences in pull-out force (p &lt; 0.008) for all luting systems (FP: 441.2±44.9 N, RXU: 390.7±80.5 N, MLP_ML: 379.3±106.8 N, LB_LCZ: 544.0±96.6 N), except when comparing RXU and MLP_ML. Pull-out forces, achieved with all luting systems, were significantly higher compared to the control (211.2±35.1 N). The main failure for FP was found between luting system and post (92.3%) while main failure for RXU (99.5%), MLP_ML (95.8%), LB_LCZ (65.5%) was found between dentin and luting system. Conclusion: Post fit and luting system influenced the pull-out force of conventionally and adhesively luted FRCPs. Congruent post fit achieved the highest pull-out forces. The three-step Etch &amp; Rinse adhesive luting system LB_LCZ generated considerably higher pull-out forces than all other tested luting systems.","abstract_has_math":false,"creators":["Berthold, Christine"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Craniofacial Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-19T14:59:39Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/53995","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/53995","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/53995/1/ubc_2015_september_berthold_christine.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F53995","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Berthold, Christine"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Craniofacial Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/53995","http://circle.library.ubc.ca/bitstream/2429/53995/1/ubc_2015_september_berthold_christine.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Objective: To evaluate the influence of post fit and luting system on pull-out force and failure mode of conventionally and adhesively luted fiber-reinforced composite posts (FRCP). Methods: 260 extracted bovine deciduous teeth were randomly assigned to each of the four luting systems (Fuji Plus (FP), RelyX Unicem (RXU), Multilink Primer/Multilink (MLP_ML), LuxaBond/LuxaCore Z (LB_LCZ and three post fits (Congruency (C), medium incongruency (MIC), high incongruency (HIC)) (n=20/group). The teeth were decapitated, root canal treated, embedded and post space was prepared. The FRCPs (Macro-Lock Post sizes 1, 3 and 6) were pretreated and inserted, according to the manufacturer’s instructions. The custom-made titanium-post was inserted with Ketac Cem (control) (n=20). After water storage (24h, 37°C), pull-out test was performed. The data were analyzed using Kolmogorov-Smirnov test (p>0.05), Two-way ANOVA and post-hoc tests (Dunnett T3 with Bonferroni correction) (α=0.05). Failure mode was assessed using a stereomicroscope. Results: The influence of post fit and luting system was statistically significant (p<0.001), while the interaction of the two factors was not (p = 0.030). When comparing pull-out forces for the three post fits, significant differences (p < 0.017) were found between C (436.6±148.7 N) and MIC (426.0±102.1 N) and C and HIC (397.5±89.8 N). Failure mode was dominated by failure between dentin and luting system (64.2-70.7%) and between luting system and post (29.3-35.5%), for all post fit groups. Pairwise comparison revealed significant differences in pull-out force (p < 0.008) for all luting systems (FP: 441.2±44.9 N, RXU: 390.7±80.5 N, MLP_ML: 379.3±106.8 N, LB_LCZ: 544.0±96.6 N), except when comparing RXU and MLP_ML. Pull-out forces, achieved with all luting systems, were significantly higher compared to the control (211.2±35.1 N). The main failure for FP was found between luting system and post (92.3%) while main failure for RXU (99.5%), MLP_ML (95.8%), LB_LCZ (65.5%) was found between dentin and luting system. Conclusion: Post fit and luting system influenced the pull-out force of conventionally and adhesively luted FRCPs. Congruent post fit achieved the highest pull-out forces. The three-step Etch & Rinse adhesive luting system LB_LCZ generated considerably higher pull-out forces than all other tested luting systems."]},{"key":"dc:format","label":"Dc Format","values":["7805072","application/pdf"]},{"key":"dc:title","label":"Title","values":["Restoration of endodontically treated immature teeth : influence of post fit on bonding properties of conventionally and adhesively luted fiber-reinforced composite posts"]}]}],"canonical_facts":{"dc:creator":["Berthold, Christine"],"dc:date":["2015"],"dc:description":["Objective: To evaluate the influence of post fit and luting system on pull-out force and failure mode of conventionally and adhesively luted fiber-reinforced composite posts (FRCP). Methods: 260 extracted bovine deciduous teeth were randomly assigned to each of the four luting systems (Fuji Plus (FP), RelyX Unicem (RXU), Multilink Primer/Multilink (MLP_ML), LuxaBond/LuxaCore Z (LB_LCZ and three post fits (Congruency (C), medium incongruency (MIC), high incongruency (HIC)) (n=20/group). The teeth were decapitated, root canal treated, embedded and post space was prepared. The FRCPs (Macro-Lock Post sizes 1, 3 and 6) were pretreated and inserted, according to the manufacturer’s instructions. The custom-made titanium-post was inserted with Ketac Cem (control) (n=20). After water storage (24h, 37°C), pull-out test was performed. The data were analyzed using Kolmogorov-Smirnov test (p>0.05), Two-way ANOVA and post-hoc tests (Dunnett T3 with Bonferroni correction) (α=0.05). Failure mode was assessed using a stereomicroscope. Results: The influence of post fit and luting system was statistically significant (p<0.001), while the interaction of the two factors was not (p = 0.030). When comparing pull-out forces for the three post fits, significant differences (p < 0.017) were found between C (436.6±148.7 N) and MIC (426.0±102.1 N) and C and HIC (397.5±89.8 N). Failure mode was dominated by failure between dentin and luting system (64.2-70.7%) and between luting system and post (29.3-35.5%), for all post fit groups. Pairwise comparison revealed significant differences in pull-out force (p < 0.008) for all luting systems (FP: 441.2±44.9 N, RXU: 390.7±80.5 N, MLP_ML: 379.3±106.8 N, LB_LCZ: 544.0±96.6 N), except when comparing RXU and MLP_ML. Pull-out forces, achieved with all luting systems, were significantly higher compared to the control (211.2±35.1 N). The main failure for FP was found between luting system and post (92.3%) while main failure for RXU (99.5%), MLP_ML (95.8%), LB_LCZ (65.5%) was found between dentin and luting system. Conclusion: Post fit and luting system influenced the pull-out force of conventionally and adhesively luted FRCPs. Congruent post fit achieved the highest pull-out forces. The three-step Etch & Rinse adhesive luting system LB_LCZ generated considerably higher pull-out forces than all other tested luting systems."],"dc:format":["7805072","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/53995","http://circle.library.ubc.ca/bitstream/2429/53995/1/ubc_2015_september_berthold_christine.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/","Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:title":["Restoration of endodontically treated immature teeth : influence of post fit on bonding properties of conventionally and adhesively luted fiber-reinforced composite posts"],"dc:type":["Text"],"thesis:degree_discipline":["Craniofacial Science"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:59:39Z"}