{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/58912"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/58912","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Effective image registration for motion estimation in medical imaging environments","abstract":"Motion estimation is a key enabler for many advanced medical imaging / image analysis applications, and hence is of signiﬁcant clinical interest. In this thesis, we study image registration for motion estimation in medical imaging environments, and focus on two clinically interesting problems: 1) deformable respiratory motion estimation from dynamic Magnetic Resonance Imagings (MRIs), and 2) rigid-body object motion estimation (e.g., surgical devices, implants) from ﬂuoroscopic images. Respiratory motion is a major complicating factor in many image acquisition applications and image-guided interventions. Existing respiratory motion estimation methods typically rely on motion models learned from retrospective data, and therefore are vulnerable to unseen respiratory motion patterns. To address this limitation, we propose to use dynamic MRI acquisition protocol to monitor respiratory motion, and a scatter to volume registration method that can directly recover the dense motion ﬁelds from the dynamic MRI data without explicitly modeling the motion. The proposed method achieves signiﬁcantly higher motion estimation accuracy than the state-of-the-art methods in addressing varying respiratory motion patterns. Object motion estimation from ﬂuoroscopic images is an enabling technology for advanced image guidance applications for Image-Guided Therapy (IGT). Complex and time-critical clinical procedures typically require the motion estimation to be accurate, robust and real-time, which cannot be achieved by existing methods at the same time. We study 2-D/3-D registration for rigid-body object motion estimation to address the above challenges, and propose two new approaches to signiﬁcantly improve the robustness and computational efﬁciency of 2-D/3-D registration. We ﬁrst propose to use pre-generated canonical form Digitally Reconstructed Radiographs (DRRs) to accelerate the DRR generation during intensity-based 2-D/3-D registration, which boosts the computational efﬁciency by ten-fold with little degradation in registration accuracy and robustness. We further demonstrate that the widely adopted intensity-based formulation for 2-D/3-D registration is ineffective, and propose a more effective regression-based formulation, solved using Convolutional Neural Network (CNN). The proposed regression-based approach achieves signiﬁcantly higher robustness, capture range and computational efﬁciency than state-of-the-art intensity-base approaches.","abstract_html":"Motion estimation is a key enabler for many advanced medical imaging / image analysis applications, and hence is of signiﬁcant clinical interest. In this thesis, we study image registration for motion estimation in medical imaging environments, and focus on two clinically interesting problems: 1) deformable respiratory motion estimation from dynamic Magnetic Resonance Imagings (MRIs), and 2) rigid-body object motion estimation (e.g., surgical devices, implants) from ﬂuoroscopic images. Respiratory motion is a major complicating factor in many image acquisition applications and image-guided interventions. Existing respiratory motion estimation methods typically rely on motion models learned from retrospective data, and therefore are vulnerable to unseen respiratory motion patterns. To address this limitation, we propose to use dynamic MRI acquisition protocol to monitor respiratory motion, and a scatter to volume registration method that can directly recover the dense motion ﬁelds from the dynamic MRI data without explicitly modeling the motion. The proposed method achieves signiﬁcantly higher motion estimation accuracy than the state-of-the-art methods in addressing varying respiratory motion patterns. Object motion estimation from ﬂuoroscopic images is an enabling technology for advanced image guidance applications for Image-Guided Therapy (IGT). Complex and time-critical clinical procedures typically require the motion estimation to be accurate, robust and real-time, which cannot be achieved by existing methods at the same time. We study 2-D/3-D registration for rigid-body object motion estimation to address the above challenges, and propose two new approaches to signiﬁcantly improve the robustness and computational efﬁciency of 2-D/3-D registration. We ﬁrst propose to use pre-generated canonical form Digitally Reconstructed Radiographs (DRRs) to accelerate the DRR generation during intensity-based 2-D/3-D registration, which boosts the computational efﬁciency by ten-fold with little degradation in registration accuracy and robustness. We further demonstrate that the widely adopted intensity-based formulation for 2-D/3-D registration is ineffective, and propose a more effective regression-based formulation, solved using Convolutional Neural Network (CNN). The proposed regression-based approach achieves signiﬁcantly higher robustness, capture range and computational efﬁciency than state-of-the-art intensity-base approaches.","abstract_has_math":false,"creators":["Miao, Shun"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T15:00:36Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/58912","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/58912","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/58912/5/ubc_2016_september_miao_shun.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F58912","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Miao, Shun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/58912","http://circle.library.ubc.ca/bitstream/2429/58912/5/ubc_2016_september_miao_shun.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Motion estimation is a key enabler for many advanced medical imaging / image analysis applications, and hence is of signiﬁcant clinical interest. In this thesis, we study image registration for motion estimation in medical imaging environments, and focus on two clinically interesting problems: 1) deformable respiratory motion estimation from dynamic Magnetic Resonance Imagings (MRIs), and 2) rigid-body object motion estimation (e.g., surgical devices, implants) from ﬂuoroscopic images. Respiratory motion is a major complicating factor in many image acquisition applications and image-guided interventions. Existing respiratory motion estimation methods typically rely on motion models learned from retrospective data, and therefore are vulnerable to unseen respiratory motion patterns. To address this limitation, we propose to use dynamic MRI acquisition protocol to monitor respiratory motion, and a scatter to volume registration method that can directly recover the dense motion ﬁelds from the dynamic MRI data without explicitly modeling the motion. The proposed method achieves signiﬁcantly higher motion estimation accuracy than the state-of-the-art methods in addressing varying respiratory motion patterns. Object motion estimation from ﬂuoroscopic images is an enabling technology for advanced image guidance applications for Image-Guided Therapy (IGT). Complex and time-critical clinical procedures typically require the motion estimation to be accurate, robust and real-time, which cannot be achieved by existing methods at the same time. We study 2-D/3-D registration for rigid-body object motion estimation to address the above challenges, and propose two new approaches to signiﬁcantly improve the robustness and computational efﬁciency of 2-D/3-D registration. We ﬁrst propose to use pre-generated canonical form Digitally Reconstructed Radiographs (DRRs) to accelerate the DRR generation during intensity-based 2-D/3-D registration, which boosts the computational efﬁciency by ten-fold with little degradation in registration accuracy and robustness. We further demonstrate that the widely adopted intensity-based formulation for 2-D/3-D registration is ineffective, and propose a more effective regression-based formulation, solved using Convolutional Neural Network (CNN). The proposed regression-based approach achieves signiﬁcantly higher robustness, capture range and computational efﬁciency than state-of-the-art intensity-base approaches."]},{"key":"dc:format","label":"Dc Format","values":["9090358","application/pdf"]},{"key":"dc:title","label":"Title","values":["Effective image registration for motion estimation in medical imaging environments"]}]}],"canonical_facts":{"dc:creator":["Miao, Shun"],"dc:date":["2016"],"dc:description":["Motion estimation is a key enabler for many advanced medical imaging / image analysis applications, and hence is of signiﬁcant clinical interest. In this thesis, we study image registration for motion estimation in medical imaging environments, and focus on two clinically interesting problems: 1) deformable respiratory motion estimation from dynamic Magnetic Resonance Imagings (MRIs), and 2) rigid-body object motion estimation (e.g., surgical devices, implants) from ﬂuoroscopic images. Respiratory motion is a major complicating factor in many image acquisition applications and image-guided interventions. Existing respiratory motion estimation methods typically rely on motion models learned from retrospective data, and therefore are vulnerable to unseen respiratory motion patterns. To address this limitation, we propose to use dynamic MRI acquisition protocol to monitor respiratory motion, and a scatter to volume registration method that can directly recover the dense motion ﬁelds from the dynamic MRI data without explicitly modeling the motion. The proposed method achieves signiﬁcantly higher motion estimation accuracy than the state-of-the-art methods in addressing varying respiratory motion patterns. Object motion estimation from ﬂuoroscopic images is an enabling technology for advanced image guidance applications for Image-Guided Therapy (IGT). Complex and time-critical clinical procedures typically require the motion estimation to be accurate, robust and real-time, which cannot be achieved by existing methods at the same time. We study 2-D/3-D registration for rigid-body object motion estimation to address the above challenges, and propose two new approaches to signiﬁcantly improve the robustness and computational efﬁciency of 2-D/3-D registration. We ﬁrst propose to use pre-generated canonical form Digitally Reconstructed Radiographs (DRRs) to accelerate the DRR generation during intensity-based 2-D/3-D registration, which boosts the computational efﬁciency by ten-fold with little degradation in registration accuracy and robustness. We further demonstrate that the widely adopted intensity-based formulation for 2-D/3-D registration is ineffective, and propose a more effective regression-based formulation, solved using Convolutional Neural Network (CNN). The proposed regression-based approach achieves signiﬁcantly higher robustness, capture range and computational efﬁciency than state-of-the-art intensity-base approaches."],"dc:format":["9090358","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/58912","http://circle.library.ubc.ca/bitstream/2429/58912/5/ubc_2016_september_miao_shun.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Effective image registration for motion estimation in medical imaging environments"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:00:36Z"}