{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/62913"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/62913","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Fluoride removal from zinc sulfate solution","abstract":"During zinc electrowinning, fluoride is the primary cause of aluminum cathode corrosion and the onset of difficulty in stripping zinc from the aluminum blank. It is therefore of great interest to determine how to remove fluoride from zinc plant solutions to prevent cathode corrosion and difficult stripping. There has been recent work on the removal of fluoride from drinking water and ground water. Research on zinc sulfate electrolyte purification has focused on metallic impurity removal, for example Cu, Co,Ni, Cd, Ti while halide impurities have been briefly investigated. Therefore, the purpose of this work is to investigate a reliable and economical process for fluoride removal from zinc sulfate electrolyte. In this work, aluminum pre-loaded Lewatit® MonoPlus TP 260 resin was introduced as the absorbent. This absorbent has a high fluoride-loading capacity through the formation of aluminum-fluoride complexes on the resin structure. Also, both aluminum chloride and aluminum sulfate have been found to be effective sources of aluminum for pre-loading of the resin. The loaded aluminum along with co-loaded fluoride may be removed by sulfuric acid stripping. The resin can then be conditioned with sodium hydroxide prior to be re-loaded with aluminum. As for the results, when 10 ppm fluoride existed in the initial solution, the fluoride capacity of the aluminum pre-loaded resin was calculated as 7.4 g F/L resin. Additionally, the breakthrough point could achieve 1000 bed volumes. Therefore, the cycle of aluminum sulfate pre-loading, fluoride-loading, sulfuric acid stripping, sodium hydroxide regeneration was recommended for effective fluoride removal in the zinc sulfate system.","abstract_html":"During zinc electrowinning, fluoride is the primary cause of aluminum cathode corrosion and the onset of difficulty in stripping zinc from the aluminum blank. It is therefore of great interest to determine how to remove fluoride from zinc plant solutions to prevent cathode corrosion and difficult stripping. There has been recent work on the removal of fluoride from drinking water and ground water. Research on zinc sulfate electrolyte purification has focused on metallic impurity removal, for example Cu, Co,Ni, Cd, Ti while halide impurities have been briefly investigated. Therefore, the purpose of this work is to investigate a reliable and economical process for fluoride removal from zinc sulfate electrolyte. In this work, aluminum pre-loaded Lewatit® MonoPlus TP 260 resin was introduced as the absorbent. This absorbent has a high fluoride-loading capacity through the formation of aluminum-fluoride complexes on the resin structure. Also, both aluminum chloride and aluminum sulfate have been found to be effective sources of aluminum for pre-loading of the resin. The loaded aluminum along with co-loaded fluoride may be removed by sulfuric acid stripping. The resin can then be conditioned with sodium hydroxide prior to be re-loaded with aluminum. As for the results, when 10 ppm fluoride existed in the initial solution, the fluoride capacity of the aluminum pre-loaded resin was calculated as 7.4 g F/L resin. Additionally, the breakthrough point could achieve 1000 bed volumes. Therefore, the cycle of aluminum sulfate pre-loading, fluoride-loading, sulfuric acid stripping, sodium hydroxide regeneration was recommended for effective fluoride removal in the zinc sulfate system.","abstract_has_math":false,"creators":["Liu, Yang"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T15:01:36Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/62913","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/62913","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/62913/7/ubc_2017_november_yang_liu.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F62913","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Liu, Yang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/62913","http://circle.library.ubc.ca/bitstream/2429/62913/7/ubc_2017_november_yang_liu.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["During zinc electrowinning, fluoride is the primary cause of aluminum cathode corrosion and the onset of difficulty in stripping zinc from the aluminum blank. It is therefore of great interest to determine how to remove fluoride from zinc plant solutions to prevent cathode corrosion and difficult stripping. There has been recent work on the removal of fluoride from drinking water and ground water. Research on zinc sulfate electrolyte purification has focused on metallic impurity removal, for example Cu, Co,Ni, Cd, Ti while halide impurities have been briefly investigated. Therefore, the purpose of this work is to investigate a reliable and economical process for fluoride removal from zinc sulfate electrolyte. In this work, aluminum pre-loaded Lewatit® MonoPlus TP 260 resin was introduced as the absorbent. This absorbent has a high fluoride-loading capacity through the formation of aluminum-fluoride complexes on the resin structure. Also, both aluminum chloride and aluminum sulfate have been found to be effective sources of aluminum for pre-loading of the resin. The loaded aluminum along with co-loaded fluoride may be removed by sulfuric acid stripping. The resin can then be conditioned with sodium hydroxide prior to be re-loaded with aluminum. As for the results, when 10 ppm fluoride existed in the initial solution, the fluoride capacity of the aluminum pre-loaded resin was calculated as 7.4 g F/L resin. Additionally, the breakthrough point could achieve 1000 bed volumes. Therefore, the cycle of aluminum sulfate pre-loading, fluoride-loading, sulfuric acid stripping, sodium hydroxide regeneration was recommended for effective fluoride removal in the zinc sulfate system."]},{"key":"dc:format","label":"Dc Format","values":["82667483","application/pdf"]},{"key":"dc:title","label":"Title","values":["Fluoride removal from zinc sulfate solution"]}]}],"canonical_facts":{"dc:creator":["Liu, Yang"],"dc:date":["2017"],"dc:description":["During zinc electrowinning, fluoride is the primary cause of aluminum cathode corrosion and the onset of difficulty in stripping zinc from the aluminum blank. It is therefore of great interest to determine how to remove fluoride from zinc plant solutions to prevent cathode corrosion and difficult stripping. There has been recent work on the removal of fluoride from drinking water and ground water. Research on zinc sulfate electrolyte purification has focused on metallic impurity removal, for example Cu, Co,Ni, Cd, Ti while halide impurities have been briefly investigated. Therefore, the purpose of this work is to investigate a reliable and economical process for fluoride removal from zinc sulfate electrolyte. In this work, aluminum pre-loaded Lewatit® MonoPlus TP 260 resin was introduced as the absorbent. This absorbent has a high fluoride-loading capacity through the formation of aluminum-fluoride complexes on the resin structure. Also, both aluminum chloride and aluminum sulfate have been found to be effective sources of aluminum for pre-loading of the resin. The loaded aluminum along with co-loaded fluoride may be removed by sulfuric acid stripping. The resin can then be conditioned with sodium hydroxide prior to be re-loaded with aluminum. As for the results, when 10 ppm fluoride existed in the initial solution, the fluoride capacity of the aluminum pre-loaded resin was calculated as 7.4 g F/L resin. Additionally, the breakthrough point could achieve 1000 bed volumes. Therefore, the cycle of aluminum sulfate pre-loading, fluoride-loading, sulfuric acid stripping, sodium hydroxide regeneration was recommended for effective fluoride removal in the zinc sulfate system."],"dc:format":["82667483","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/62913","http://circle.library.ubc.ca/bitstream/2429/62913/7/ubc_2017_november_yang_liu.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Fluoride removal from zinc sulfate solution"],"dc:type":["Text"],"thesis:degree_discipline":["Materials Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:01:36Z"}