{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/64704"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/64704","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Monitoring the efficacy of a field-based heat acclimatization protocol to improve performance in elite female soccer players.","abstract":"The purpose of this study was to investigate the efficacy of a 14-day, two-phase, field-based heat acclimatization (HA) training camp in international female soccer players. Sixteen outfield players engaged in (i) baseline absolute Plasma volume (PV) testing in Vancouver, Canada (~15˚C; 72.0% relative humidity: RH) 16 days prior to the start of the camp, (ii) Phase 1: 7 days of pre-HA (22.1±3.3˚C; 44.8±9.4%RH), (iii) Phase 2: 6 days of HA (34.5±1.2˚C; 53.2±4.3%RH), and (iv) 11 days of post-HA training (18.2±4.6˚C; 51.3±20.9%RH). Change in PV (%) from baseline was measured at the start of Phase 1, the end of Phase 1, and two days post-Phase 2. Core temperature (Tc), heart rate (HR), rate of perceived exertion (RPE), and Global Positioning System (GPS) derived metrics were recorded during all sessions. The physiological change during 5’-1’ submaximal running (12km/h) was observed pre and post Phase 1 and 2, two days post Phase 2 (2dayP), and eleven days post Phase 2 (11dayP) using HR during exercise (HRex) and recovery (HRR), as well as RPE. GPS metrics, HRR, and HRex during a four-a-side soccer game (4v4SSG) were used to observe physical performance in the heat pre and post Phase 2. All data were analyzed using magnitude-based inference statistics. PV increased by 7.4±3.6% (Standardized effect; SE=0.63) from the start of Phase 1 to the end of Phase 2, and this occurred primarily in Phase 1 (SE=0.64). 5’-1’ submaximal running improved over Phase 2 in hot conditions (HRex; SE= -0.49, HRR; SE=0.53). The greatest improvement in submaximal running in temperate conditions was delayed as the largest change from Phase 1 in HRex (SE= -0.42) and HRR (SE= 0.37) occurred 11dayP. The 4v4SSG revealed a moderate reduction in HRex (-3.5bpm), a large increase in HRR (5.7%), and a moderate increase in inertial explosive movements (20%) from pre to post Phase 2. Field-based HA can induce physiological change beneficial to soccer performance in temperate and hot conditions and the 5’-1’ submaximal running test may be used to effectively monitor submaximal HR responses that may have been induced by HA up to two-weeks out of the heat.","abstract_html":"The purpose of this study was to investigate the efficacy of a 14-day, two-phase, field-based heat acclimatization (HA) training camp in international female soccer players. Sixteen outfield players engaged in (i) baseline absolute Plasma volume (PV) testing in Vancouver, Canada (~15˚C; 72.0% relative humidity: RH) 16 days prior to the start of the camp, (ii) Phase 1: 7 days of pre-HA (22.1±3.3˚C; 44.8±9.4%RH), (iii) Phase 2: 6 days of HA (34.5±1.2˚C; 53.2±4.3%RH), and (iv) 11 days of post-HA training (18.2±4.6˚C; 51.3±20.9%RH). Change in PV (%) from baseline was measured at the start of Phase 1, the end of Phase 1, and two days post-Phase 2. Core temperature (Tc), heart rate (HR), rate of perceived exertion (RPE), and Global Positioning System (GPS) derived metrics were recorded during all sessions. The physiological change during 5’-1’ submaximal running (12km/h) was observed pre and post Phase 1 and 2, two days post Phase 2 (2dayP), and eleven days post Phase 2 (11dayP) using HR during exercise (HRex) and recovery (HRR), as well as RPE. GPS metrics, HRR, and HRex during a four-a-side soccer game (4v4SSG) were used to observe physical performance in the heat pre and post Phase 2. All data were analyzed using magnitude-based inference statistics. PV increased by 7.4±3.6% (Standardized effect; SE=0.63) from the start of Phase 1 to the end of Phase 2, and this occurred primarily in Phase 1 (SE=0.64). 5’-1’ submaximal running improved over Phase 2 in hot conditions (HRex; SE= -0.49, HRR; SE=0.53). The greatest improvement in submaximal running in temperate conditions was delayed as the largest change from Phase 1 in HRex (SE= -0.42) and HRR (SE= 0.37) occurred 11dayP. The 4v4SSG revealed a moderate reduction in HRex (-3.5bpm), a large increase in HRR (5.7%), and a moderate increase in inertial explosive movements (20%) from pre to post Phase 2. Field-based HA can induce physiological change beneficial to soccer performance in temperate and hot conditions and the 5’-1’ submaximal running test may be used to effectively monitor submaximal HR responses that may have been induced by HA up to two-weeks out of the heat.","abstract_has_math":false,"creators":["Bowman, Kimberly"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Kinesiology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T15:01:54Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/64704","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/64704","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/64704/1/ubc_2018_may_bowman_kimberly.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F64704","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bowman, Kimberly"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/64704","http://circle.library.ubc.ca/bitstream/2429/64704/1/ubc_2018_may_bowman_kimberly.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to investigate the efficacy of a 14-day, two-phase, field-based heat acclimatization (HA) training camp in international female soccer players. Sixteen outfield players engaged in (i) baseline absolute Plasma volume (PV) testing in Vancouver, Canada (~15˚C; 72.0% relative humidity: RH) 16 days prior to the start of the camp, (ii) Phase 1: 7 days of pre-HA (22.1±3.3˚C; 44.8±9.4%RH), (iii) Phase 2: 6 days of HA (34.5±1.2˚C; 53.2±4.3%RH), and (iv) 11 days of post-HA training (18.2±4.6˚C; 51.3±20.9%RH). Change in PV (%) from baseline was measured at the start of Phase 1, the end of Phase 1, and two days post-Phase 2. Core temperature (Tc), heart rate (HR), rate of perceived exertion (RPE), and Global Positioning System (GPS) derived metrics were recorded during all sessions. The physiological change during 5’-1’ submaximal running (12km/h) was observed pre and post Phase 1 and 2, two days post Phase 2 (2dayP), and eleven days post Phase 2 (11dayP) using HR during exercise (HRex) and recovery (HRR), as well as RPE. GPS metrics, HRR, and HRex during a four-a-side soccer game (4v4SSG) were used to observe physical performance in the heat pre and post Phase 2. All data were analyzed using magnitude-based inference statistics. PV increased by 7.4±3.6% (Standardized effect; SE=0.63) from the start of Phase 1 to the end of Phase 2, and this occurred primarily in Phase 1 (SE=0.64). 5’-1’ submaximal running improved over Phase 2 in hot conditions (HRex; SE= -0.49, HRR; SE=0.53). The greatest improvement in submaximal running in temperate conditions was delayed as the largest change from Phase 1 in HRex (SE= -0.42) and HRR (SE= 0.37) occurred 11dayP. The 4v4SSG revealed a moderate reduction in HRex (-3.5bpm), a large increase in HRR (5.7%), and a moderate increase in inertial explosive movements (20%) from pre to post Phase 2. Field-based HA can induce physiological change beneficial to soccer performance in temperate and hot conditions and the 5’-1’ submaximal running test may be used to effectively monitor submaximal HR responses that may have been induced by HA up to two-weeks out of the heat."]},{"key":"dc:format","label":"Dc Format","values":["2883709","application/pdf"]},{"key":"dc:title","label":"Title","values":["Monitoring the efficacy of a field-based heat acclimatization protocol to improve performance in elite female soccer players."]}]}],"canonical_facts":{"dc:creator":["Bowman, Kimberly"],"dc:date":["2018"],"dc:description":["The purpose of this study was to investigate the efficacy of a 14-day, two-phase, field-based heat acclimatization (HA) training camp in international female soccer players. Sixteen outfield players engaged in (i) baseline absolute Plasma volume (PV) testing in Vancouver, Canada (~15˚C; 72.0% relative humidity: RH) 16 days prior to the start of the camp, (ii) Phase 1: 7 days of pre-HA (22.1±3.3˚C; 44.8±9.4%RH), (iii) Phase 2: 6 days of HA (34.5±1.2˚C; 53.2±4.3%RH), and (iv) 11 days of post-HA training (18.2±4.6˚C; 51.3±20.9%RH). Change in PV (%) from baseline was measured at the start of Phase 1, the end of Phase 1, and two days post-Phase 2. Core temperature (Tc), heart rate (HR), rate of perceived exertion (RPE), and Global Positioning System (GPS) derived metrics were recorded during all sessions. The physiological change during 5’-1’ submaximal running (12km/h) was observed pre and post Phase 1 and 2, two days post Phase 2 (2dayP), and eleven days post Phase 2 (11dayP) using HR during exercise (HRex) and recovery (HRR), as well as RPE. GPS metrics, HRR, and HRex during a four-a-side soccer game (4v4SSG) were used to observe physical performance in the heat pre and post Phase 2. All data were analyzed using magnitude-based inference statistics. PV increased by 7.4±3.6% (Standardized effect; SE=0.63) from the start of Phase 1 to the end of Phase 2, and this occurred primarily in Phase 1 (SE=0.64). 5’-1’ submaximal running improved over Phase 2 in hot conditions (HRex; SE= -0.49, HRR; SE=0.53). The greatest improvement in submaximal running in temperate conditions was delayed as the largest change from Phase 1 in HRex (SE= -0.42) and HRR (SE= 0.37) occurred 11dayP. The 4v4SSG revealed a moderate reduction in HRex (-3.5bpm), a large increase in HRR (5.7%), and a moderate increase in inertial explosive movements (20%) from pre to post Phase 2. Field-based HA can induce physiological change beneficial to soccer performance in temperate and hot conditions and the 5’-1’ submaximal running test may be used to effectively monitor submaximal HR responses that may have been induced by HA up to two-weeks out of the heat."],"dc:format":["2883709","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/64704","http://circle.library.ubc.ca/bitstream/2429/64704/1/ubc_2018_may_bowman_kimberly.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Monitoring the efficacy of a field-based heat acclimatization protocol to improve performance in elite female soccer players."],"dc:type":["Text"],"thesis:degree_discipline":["Kinesiology"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:01:54Z"}