{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/6576"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/6576","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A gallium arsenide CCD X-Ray detector","abstract":"A one dimensional buried channel CCD with a 30 /urn thick intrinsic layer was manufactured at TRIUMF for use as a radiation detector. In order to characterize the detector's response to radiation, six discrete X-Ray sources with energies ranging from 8 KeV to 60 keV were impinged on the device. An algorithm was developed to convert events detected by the CCD into spectra characteristic of each X-Ray source. The range of energies detectable and the energy resolution of the detector at different energies were studied.A model was developed and used to explain the shape of each spectrum. The spectrum from an 241Am source was also studied to determine the detector's response to a multi-energetic source.","abstract_html":"A one dimensional buried channel CCD with a 30 /urn thick intrinsic layer was manufactured at TRIUMF for use as a radiation detector. In order to characterize the detector&#x27;s response to radiation, six discrete X-Ray sources with energies ranging from 8 KeV to 60 keV were impinged on the device. An algorithm was developed to convert events detected by the CCD into spectra characteristic of each X-Ray source. The range of energies detectable and the energy resolution of the detector at different energies were studied.A model was developed and used to explain the shape of each spectrum. The spectrum from an 241Am source was also studied to determine the detector&#x27;s response to a multi-energetic source.","abstract_has_math":false,"creators":["Patten, Scott"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997","date_published":"1997","updated_at":"2026-11-19T14:26:29Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/6576","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/6576","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/6576/1/ubc_1997-0584.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F6576","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Patten, Scott"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1997"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/6576","http://circle.library.ubc.ca/bitstream/2429/6576/1/ubc_1997-0584.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A one dimensional buried channel CCD with a 30 /urn thick intrinsic layer was manufactured at TRIUMF for use as a radiation detector. In order to characterize the detector's response to radiation, six discrete X-Ray sources with energies ranging from 8 KeV to 60 keV were impinged on the device. An algorithm was developed to convert events detected by the CCD into spectra characteristic of each X-Ray source. The range of energies detectable and the energy resolution of the detector at different energies were studied.A model was developed and used to explain the shape of each spectrum. The spectrum from an 241Am source was also studied to determine the detector's response to a multi-energetic source."]},{"key":"dc:format","label":"Dc Format","values":["3438415","application/pdf"]},{"key":"dc:title","label":"Title","values":["A gallium arsenide CCD X-Ray detector"]}]}],"canonical_facts":{"dc:creator":["Patten, Scott"],"dc:date":["1997"],"dc:description":["A one dimensional buried channel CCD with a 30 /urn thick intrinsic layer was manufactured at TRIUMF for use as a radiation detector. In order to characterize the detector's response to radiation, six discrete X-Ray sources with energies ranging from 8 KeV to 60 keV were impinged on the device. An algorithm was developed to convert events detected by the CCD into spectra characteristic of each X-Ray source. The range of energies detectable and the energy resolution of the detector at different energies were studied.A model was developed and used to explain the shape of each spectrum. The spectrum from an 241Am source was also studied to determine the detector's response to a multi-energetic source."],"dc:format":["3438415","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/6576","http://circle.library.ubc.ca/bitstream/2429/6576/1/ubc_1997-0584.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A gallium arsenide CCD X-Ray detector"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:26:29Z"}