{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/66317"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/66317","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Experimental 4-step braided glass fiber reinforced composite for dental CAD/CAM applications","abstract":"Introduction: Computer-aided design/computer-aided manufacturing in dentistry has lead to rapid expansion of new dental materials. A new product from Shofu (Shofu, Japan), TRINIA CAD/CAM blocks and pucks, offers an alternative to the existing resin composite CAD/CAM materials. The claimed mechanical properties of TRINA provide merit to further research and development of 3D fiber reinforced composites for CAD/CAM dentistry. Objective: To design and produce 3D braided fiber-reinforced composites for dental CAD/CAM applications. Materials and Methods: Experimental groups were designed and produced in conjunction with the Department of Materials Engineering, UBC. The proposed design parameters included: 50:50 volume fraction fibers, 45-degree braiding angle, and 14 mm*14 mm cross sectional area, the approximate size of currently available CAD/CAM blocks. Continuous S-2 glass fiber roving was used as the reinforcing agent. Three experimental 3D glass fiber preforms were produced with internal structural variations using a 4-step braiding technique. A 50:50 UDMA:TEGDMA resin matrix blend with a thermal curing agent was used for infiltration via submersion under vacuum, followed by thermal curing. An unreinforced resin blend and a unidirectional fiber-reinforced composite, with the same volume fraction and dimensions, served as control groups. Samples were prepared to 4 mm*4 mm*45 mm beams for three-point-bend testing. An Instron 5969 Dual Column Material Testing System was used to test the flexural properties of the samples. Scanning electron microscopy (SEM) was used to evaluate the fractured samples. Results: Results showed that incorporation of anisotropic unidirectional fibers had the most significant effect in reinforcing the resin blend. The unidirectional control group produced the greatest flexural strength and elastic modulus at 336.6 MPa and 37.3 GPa, respectively. The 2-ply+axial group followed at 236.52 MPa and 20.75 GPa. The 2-ply had values of 196.2 MPa and 11.83 GPa. The 4-ply had values of 96.48 MPa and 4.906 GPa. The 4-ply group failed to reinforce a resin control group, which had values of 102.65 MPa and 2.467 GPa. Conclusion: Incorporation of anisotropic reinforcing fibers has most significant influence on the experimental materials flexural properties.","abstract_html":"Introduction: Computer-aided design/computer-aided manufacturing in dentistry has lead to rapid expansion of new dental materials. A new product from Shofu (Shofu, Japan), TRINIA CAD/CAM blocks and pucks, offers an alternative to the existing resin composite CAD/CAM materials. The claimed mechanical properties of TRINA provide merit to further research and development of 3D fiber reinforced composites for CAD/CAM dentistry. Objective: To design and produce 3D braided fiber-reinforced composites for dental CAD/CAM applications. Materials and Methods: Experimental groups were designed and produced in conjunction with the Department of Materials Engineering, UBC. The proposed design parameters included: 50:50 volume fraction fibers, 45-degree braiding angle, and 14 mm*14 mm cross sectional area, the approximate size of currently available CAD/CAM blocks. Continuous S-2 glass fiber roving was used as the reinforcing agent. Three experimental 3D glass fiber preforms were produced with internal structural variations using a 4-step braiding technique. A 50:50 UDMA:TEGDMA resin matrix blend with a thermal curing agent was used for infiltration via submersion under vacuum, followed by thermal curing. An unreinforced resin blend and a unidirectional fiber-reinforced composite, with the same volume fraction and dimensions, served as control groups. Samples were prepared to 4 mm*4 mm*45 mm beams for three-point-bend testing. An Instron 5969 Dual Column Material Testing System was used to test the flexural properties of the samples. Scanning electron microscopy (SEM) was used to evaluate the fractured samples. Results: Results showed that incorporation of anisotropic unidirectional fibers had the most significant effect in reinforcing the resin blend. The unidirectional control group produced the greatest flexural strength and elastic modulus at 336.6 MPa and 37.3 GPa, respectively. The 2-ply+axial group followed at 236.52 MPa and 20.75 GPa. The 2-ply had values of 196.2 MPa and 11.83 GPa. The 4-ply had values of 96.48 MPa and 4.906 GPa. The 4-ply group failed to reinforce a resin control group, which had values of 102.65 MPa and 2.467 GPa. Conclusion: Incorporation of anisotropic reinforcing fibers has most significant influence on the experimental materials flexural properties.","abstract_has_math":false,"creators":["Lesniak, Robert Matthew"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Craniofacial Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T15:02:09Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/66317","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/66317","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/66317/1/ubc_2018_september_lesniak_robert.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F66317","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lesniak, Robert Matthew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Craniofacial Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/66317","http://circle.library.ubc.ca/bitstream/2429/66317/1/ubc_2018_september_lesniak_robert.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Introduction: Computer-aided design/computer-aided manufacturing in dentistry has lead to rapid expansion of new dental materials. A new product from Shofu (Shofu, Japan), TRINIA CAD/CAM blocks and pucks, offers an alternative to the existing resin composite CAD/CAM materials. The claimed mechanical properties of TRINA provide merit to further research and development of 3D fiber reinforced composites for CAD/CAM dentistry. Objective: To design and produce 3D braided fiber-reinforced composites for dental CAD/CAM applications. Materials and Methods: Experimental groups were designed and produced in conjunction with the Department of Materials Engineering, UBC. The proposed design parameters included: 50:50 volume fraction fibers, 45-degree braiding angle, and 14 mm*14 mm cross sectional area, the approximate size of currently available CAD/CAM blocks. Continuous S-2 glass fiber roving was used as the reinforcing agent. Three experimental 3D glass fiber preforms were produced with internal structural variations using a 4-step braiding technique. A 50:50 UDMA:TEGDMA resin matrix blend with a thermal curing agent was used for infiltration via submersion under vacuum, followed by thermal curing. An unreinforced resin blend and a unidirectional fiber-reinforced composite, with the same volume fraction and dimensions, served as control groups. Samples were prepared to 4 mm*4 mm*45 mm beams for three-point-bend testing. An Instron 5969 Dual Column Material Testing System was used to test the flexural properties of the samples. Scanning electron microscopy (SEM) was used to evaluate the fractured samples. Results: Results showed that incorporation of anisotropic unidirectional fibers had the most significant effect in reinforcing the resin blend. The unidirectional control group produced the greatest flexural strength and elastic modulus at 336.6 MPa and 37.3 GPa, respectively. The 2-ply+axial group followed at 236.52 MPa and 20.75 GPa. The 2-ply had values of 196.2 MPa and 11.83 GPa. The 4-ply had values of 96.48 MPa and 4.906 GPa. The 4-ply group failed to reinforce a resin control group, which had values of 102.65 MPa and 2.467 GPa. Conclusion: Incorporation of anisotropic reinforcing fibers has most significant influence on the experimental materials flexural properties."]},{"key":"dc:format","label":"Dc Format","values":["3506359","application/pdf"]},{"key":"dc:title","label":"Title","values":["Experimental 4-step braided glass fiber reinforced composite for dental CAD/CAM applications"]}]}],"canonical_facts":{"dc:creator":["Lesniak, Robert Matthew"],"dc:date":["2018"],"dc:description":["Introduction: Computer-aided design/computer-aided manufacturing in dentistry has lead to rapid expansion of new dental materials. A new product from Shofu (Shofu, Japan), TRINIA CAD/CAM blocks and pucks, offers an alternative to the existing resin composite CAD/CAM materials. The claimed mechanical properties of TRINA provide merit to further research and development of 3D fiber reinforced composites for CAD/CAM dentistry. Objective: To design and produce 3D braided fiber-reinforced composites for dental CAD/CAM applications. Materials and Methods: Experimental groups were designed and produced in conjunction with the Department of Materials Engineering, UBC. The proposed design parameters included: 50:50 volume fraction fibers, 45-degree braiding angle, and 14 mm*14 mm cross sectional area, the approximate size of currently available CAD/CAM blocks. Continuous S-2 glass fiber roving was used as the reinforcing agent. Three experimental 3D glass fiber preforms were produced with internal structural variations using a 4-step braiding technique. A 50:50 UDMA:TEGDMA resin matrix blend with a thermal curing agent was used for infiltration via submersion under vacuum, followed by thermal curing. An unreinforced resin blend and a unidirectional fiber-reinforced composite, with the same volume fraction and dimensions, served as control groups. Samples were prepared to 4 mm*4 mm*45 mm beams for three-point-bend testing. An Instron 5969 Dual Column Material Testing System was used to test the flexural properties of the samples. Scanning electron microscopy (SEM) was used to evaluate the fractured samples. Results: Results showed that incorporation of anisotropic unidirectional fibers had the most significant effect in reinforcing the resin blend. The unidirectional control group produced the greatest flexural strength and elastic modulus at 336.6 MPa and 37.3 GPa, respectively. The 2-ply+axial group followed at 236.52 MPa and 20.75 GPa. The 2-ply had values of 196.2 MPa and 11.83 GPa. The 4-ply had values of 96.48 MPa and 4.906 GPa. The 4-ply group failed to reinforce a resin control group, which had values of 102.65 MPa and 2.467 GPa. Conclusion: Incorporation of anisotropic reinforcing fibers has most significant influence on the experimental materials flexural properties."],"dc:format":["3506359","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/66317","http://circle.library.ubc.ca/bitstream/2429/66317/1/ubc_2018_september_lesniak_robert.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Experimental 4-step braided glass fiber reinforced composite for dental CAD/CAM applications"],"dc:type":["Text"],"thesis:degree_discipline":["Craniofacial Science"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:02:09Z"}