{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/66857"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/66857","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A comparison of the mechanical properties of pigmented silicone elastomers used in maxillofacial prostheses","abstract":"Purpose: To evaluate and compare the mechanical properties of various commercially available pigmented polydimethylsiloxane elastomers (silicone elastomers) utilized in the fabrication of maxillofacial prostheses. Materials & Methods: Three commonly used silicone elastomers were evaluated: A-2000 (Factor II), A-2186 (Factor II), A-103 (Factor II). The silicones was combined with opacifier: Titanium White (Factor II), and pigment: Intrinsic Pigment in Naturelle (Factor II). Specimens were fabricated through the use of aluminum and stone moulds to form trouser- and dumbbell- shaped specimens. From each material 20 specimens were prepared, 10 dumbbell-shaped and 10 trouser-shaped (n=10) for a total of 60 specimens. Mechanical properties evaluated included: Shore-A hardness, tear strength, tensile strength, and percent elongation. These properties were tested according to ASTM protocols. Data was statistically-analyzed with one-way ANOVA of each property at the 95% level of confidence as well as Tukey’s post-hoc tests for specific identification of significant differences between materials. Results: ANOVA indicated statistically-significant differences among the three materials for each of the four outcomes tested. Further statistical analysis with Tukey’s post-hoc tests showed significantly lower tensile strength and tear strength and higher % elongation for A-103 when compared to both A-2000 and A-2186. No statistically significant differences were found between A-2000 and A-2186 with respect to tensile strength, percent elongation or tear strength. All three groups were found to be significantly different from each other in terms of Shore-A hardness. A-103 exhibited the lowest hardness values, whereas A-2186 was found to have the highest hardness. iii Conclusions: Material A-103 exhibited the lowest tensile and tear strengths as well as hardness, however, it displayed the greatest percent elongation. Material A-2000 and A-2186 displayed similar characteristics with regard to tensile and tear strengths, but differed in terms of Shore-A hardness with A-2186 exhibiting the greatest hardness.","abstract_html":"Purpose: To evaluate and compare the mechanical properties of various commercially available pigmented polydimethylsiloxane elastomers (silicone elastomers) utilized in the fabrication of maxillofacial prostheses. Materials &amp; Methods: Three commonly used silicone elastomers were evaluated: A-2000 (Factor II), A-2186 (Factor II), A-103 (Factor II). The silicones was combined with opacifier: Titanium White (Factor II), and pigment: Intrinsic Pigment in Naturelle (Factor II). Specimens were fabricated through the use of aluminum and stone moulds to form trouser- and dumbbell- shaped specimens. From each material 20 specimens were prepared, 10 dumbbell-shaped and 10 trouser-shaped (n=10) for a total of 60 specimens. Mechanical properties evaluated included: Shore-A hardness, tear strength, tensile strength, and percent elongation. These properties were tested according to ASTM protocols. Data was statistically-analyzed with one-way ANOVA of each property at the 95% level of confidence as well as Tukey’s post-hoc tests for specific identification of significant differences between materials. Results: ANOVA indicated statistically-significant differences among the three materials for each of the four outcomes tested. Further statistical analysis with Tukey’s post-hoc tests showed significantly lower tensile strength and tear strength and higher % elongation for A-103 when compared to both A-2000 and A-2186. No statistically significant differences were found between A-2000 and A-2186 with respect to tensile strength, percent elongation or tear strength. All three groups were found to be significantly different from each other in terms of Shore-A hardness. A-103 exhibited the lowest hardness values, whereas A-2186 was found to have the highest hardness. iii Conclusions: Material A-103 exhibited the lowest tensile and tear strengths as well as hardness, however, it displayed the greatest percent elongation. Material A-2000 and A-2186 displayed similar characteristics with regard to tensile and tear strengths, but differed in terms of Shore-A hardness with A-2186 exhibiting the greatest hardness.","abstract_has_math":false,"creators":["El-Mowafy, Nora"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Craniofacial Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T15:02:13Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/66857","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/66857","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/66857/1/ubc_2018_september_el-mowafy_nora.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F66857","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["El-Mowafy, Nora"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Craniofacial Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/66857","http://circle.library.ubc.ca/bitstream/2429/66857/1/ubc_2018_september_el-mowafy_nora.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Purpose: To evaluate and compare the mechanical properties of various commercially available pigmented polydimethylsiloxane elastomers (silicone elastomers) utilized in the fabrication of maxillofacial prostheses. Materials & Methods: Three commonly used silicone elastomers were evaluated: A-2000 (Factor II), A-2186 (Factor II), A-103 (Factor II). The silicones was combined with opacifier: Titanium White (Factor II), and pigment: Intrinsic Pigment in Naturelle (Factor II). Specimens were fabricated through the use of aluminum and stone moulds to form trouser- and dumbbell- shaped specimens. From each material 20 specimens were prepared, 10 dumbbell-shaped and 10 trouser-shaped (n=10) for a total of 60 specimens. Mechanical properties evaluated included: Shore-A hardness, tear strength, tensile strength, and percent elongation. These properties were tested according to ASTM protocols. Data was statistically-analyzed with one-way ANOVA of each property at the 95% level of confidence as well as Tukey’s post-hoc tests for specific identification of significant differences between materials. Results: ANOVA indicated statistically-significant differences among the three materials for each of the four outcomes tested. Further statistical analysis with Tukey’s post-hoc tests showed significantly lower tensile strength and tear strength and higher % elongation for A-103 when compared to both A-2000 and A-2186. No statistically significant differences were found between A-2000 and A-2186 with respect to tensile strength, percent elongation or tear strength. All three groups were found to be significantly different from each other in terms of Shore-A hardness. A-103 exhibited the lowest hardness values, whereas A-2186 was found to have the highest hardness. iii Conclusions: Material A-103 exhibited the lowest tensile and tear strengths as well as hardness, however, it displayed the greatest percent elongation. Material A-2000 and A-2186 displayed similar characteristics with regard to tensile and tear strengths, but differed in terms of Shore-A hardness with A-2186 exhibiting the greatest hardness."]},{"key":"dc:format","label":"Dc Format","values":["15390457","application/pdf"]},{"key":"dc:title","label":"Title","values":["A comparison of the mechanical properties of pigmented silicone elastomers used in maxillofacial prostheses"]}]}],"canonical_facts":{"dc:creator":["El-Mowafy, Nora"],"dc:date":["2018"],"dc:description":["Purpose: To evaluate and compare the mechanical properties of various commercially available pigmented polydimethylsiloxane elastomers (silicone elastomers) utilized in the fabrication of maxillofacial prostheses. Materials & Methods: Three commonly used silicone elastomers were evaluated: A-2000 (Factor II), A-2186 (Factor II), A-103 (Factor II). The silicones was combined with opacifier: Titanium White (Factor II), and pigment: Intrinsic Pigment in Naturelle (Factor II). Specimens were fabricated through the use of aluminum and stone moulds to form trouser- and dumbbell- shaped specimens. From each material 20 specimens were prepared, 10 dumbbell-shaped and 10 trouser-shaped (n=10) for a total of 60 specimens. Mechanical properties evaluated included: Shore-A hardness, tear strength, tensile strength, and percent elongation. These properties were tested according to ASTM protocols. Data was statistically-analyzed with one-way ANOVA of each property at the 95% level of confidence as well as Tukey’s post-hoc tests for specific identification of significant differences between materials. Results: ANOVA indicated statistically-significant differences among the three materials for each of the four outcomes tested. Further statistical analysis with Tukey’s post-hoc tests showed significantly lower tensile strength and tear strength and higher % elongation for A-103 when compared to both A-2000 and A-2186. No statistically significant differences were found between A-2000 and A-2186 with respect to tensile strength, percent elongation or tear strength. All three groups were found to be significantly different from each other in terms of Shore-A hardness. A-103 exhibited the lowest hardness values, whereas A-2186 was found to have the highest hardness. iii Conclusions: Material A-103 exhibited the lowest tensile and tear strengths as well as hardness, however, it displayed the greatest percent elongation. Material A-2000 and A-2186 displayed similar characteristics with regard to tensile and tear strengths, but differed in terms of Shore-A hardness with A-2186 exhibiting the greatest hardness."],"dc:format":["15390457","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/66857","http://circle.library.ubc.ca/bitstream/2429/66857/1/ubc_2018_september_el-mowafy_nora.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["A comparison of the mechanical properties of pigmented silicone elastomers used in maxillofacial prostheses"],"dc:type":["Text"],"thesis:degree_discipline":["Craniofacial Science"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:02:13Z"}