{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/67116"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/67116","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Capillary electrophoresis-mass spectrometry and complementary approaches for semi-quantitative analysis of samples with complex matrices","abstract":"Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) combines the superior separation efficiency of CE with the detection capability of MS to provide information-rich data on samples with complex matrices. CE-ESI-MS is applied to a range of complex mixtures to semi-quantify unknown components and find patterns among groups of samples. The first part of this thesis tells how the industrial generation of oil sands process-affected waters (OSPW) poses an environmental threat, and a review is given on the state-of-the-art of analytical chemistry in the semi-quantification of toxic naphthenic acid fraction compounds (NAFC) in OSPW. The chapter ends with a technical description of the CE-ESI-MS system which was utilized. CE-ESI-MS was demonstrated to produce effective analyses of a well-known complex mixture: human urine. CE-ESI-MS was used to quantify and “fingerprint” components in human urine via targeted and untargeted analyses of the sub-5 kDa urine metabolome of patients with prostate and/or bladder cancer. For targeted analysis, endogenous levels of sarcosine and 5 other metabolites were quantified in four patients and in a pooled healthy urine sample. An untargeted analysis of patient urine was also performed identifying over 400 distinct molecular features per patient. Next, a CE-ESI-MS method was developed for the analysis of a relatively unknown complex mixture: NAFCs in OSPW. A standard mixture of amine-derivatized naphthenic acids was analyzed in under 15 min, detecting NAFCs between m/z 250 and 800. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide in three different solvents. The optimum BGE composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. The optimized CE-ESI-MS method was then used to find patterns in NAFCs across porewater samples impacted by oil sands waste. CE-ESI-MS, Orbitrap MS, and a standard GC-FID method were used to characterize porewater samples. Differences in measured amounts of total petroleum hydrocarbon by GC-FID and NAFC by HRMS indicate that the two methods provide complementary information about dissolved organic species in water leachate samples. CE-ESI-MS also provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water.","abstract_html":"Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) combines the superior separation efficiency of CE with the detection capability of MS to provide information-rich data on samples with complex matrices. CE-ESI-MS is applied to a range of complex mixtures to semi-quantify unknown components and find patterns among groups of samples. The first part of this thesis tells how the industrial generation of oil sands process-affected waters (OSPW) poses an environmental threat, and a review is given on the state-of-the-art of analytical chemistry in the semi-quantification of toxic naphthenic acid fraction compounds (NAFC) in OSPW. The chapter ends with a technical description of the CE-ESI-MS system which was utilized. CE-ESI-MS was demonstrated to produce effective analyses of a well-known complex mixture: human urine. CE-ESI-MS was used to quantify and “fingerprint” components in human urine via targeted and untargeted analyses of the sub-5 kDa urine metabolome of patients with prostate and/or bladder cancer. For targeted analysis, endogenous levels of sarcosine and 5 other metabolites were quantified in four patients and in a pooled healthy urine sample. An untargeted analysis of patient urine was also performed identifying over 400 distinct molecular features per patient. Next, a CE-ESI-MS method was developed for the analysis of a relatively unknown complex mixture: NAFCs in OSPW. A standard mixture of amine-derivatized naphthenic acids was analyzed in under 15 min, detecting NAFCs between m/z 250 and 800. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide in three different solvents. The optimum BGE composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. The optimized CE-ESI-MS method was then used to find patterns in NAFCs across porewater samples impacted by oil sands waste. CE-ESI-MS, Orbitrap MS, and a standard GC-FID method were used to characterize porewater samples. Differences in measured amounts of total petroleum hydrocarbon by GC-FID and NAFC by HRMS indicate that the two methods provide complementary information about dissolved organic species in water leachate samples. CE-ESI-MS also provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water.","abstract_has_math":false,"creators":["MacLennan, Matthew S."],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T15:02:19Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/67116","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/67116","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/67116/1/ubc_2018_november_maclennan_matthew.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F67116","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["MacLennan, Matthew S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/67116","http://circle.library.ubc.ca/bitstream/2429/67116/1/ubc_2018_november_maclennan_matthew.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) combines the superior separation efficiency of CE with the detection capability of MS to provide information-rich data on samples with complex matrices. CE-ESI-MS is applied to a range of complex mixtures to semi-quantify unknown components and find patterns among groups of samples. The first part of this thesis tells how the industrial generation of oil sands process-affected waters (OSPW) poses an environmental threat, and a review is given on the state-of-the-art of analytical chemistry in the semi-quantification of toxic naphthenic acid fraction compounds (NAFC) in OSPW. The chapter ends with a technical description of the CE-ESI-MS system which was utilized. CE-ESI-MS was demonstrated to produce effective analyses of a well-known complex mixture: human urine. CE-ESI-MS was used to quantify and “fingerprint” components in human urine via targeted and untargeted analyses of the sub-5 kDa urine metabolome of patients with prostate and/or bladder cancer. For targeted analysis, endogenous levels of sarcosine and 5 other metabolites were quantified in four patients and in a pooled healthy urine sample. An untargeted analysis of patient urine was also performed identifying over 400 distinct molecular features per patient. Next, a CE-ESI-MS method was developed for the analysis of a relatively unknown complex mixture: NAFCs in OSPW. A standard mixture of amine-derivatized naphthenic acids was analyzed in under 15 min, detecting NAFCs between m/z 250 and 800. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide in three different solvents. The optimum BGE composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. The optimized CE-ESI-MS method was then used to find patterns in NAFCs across porewater samples impacted by oil sands waste. CE-ESI-MS, Orbitrap MS, and a standard GC-FID method were used to characterize porewater samples. Differences in measured amounts of total petroleum hydrocarbon by GC-FID and NAFC by HRMS indicate that the two methods provide complementary information about dissolved organic species in water leachate samples. CE-ESI-MS also provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water."]},{"key":"dc:format","label":"Dc Format","values":["4102318","application/pdf"]},{"key":"dc:title","label":"Title","values":["Capillary electrophoresis-mass spectrometry and complementary approaches for semi-quantitative analysis of samples with complex matrices"]}]}],"canonical_facts":{"dc:creator":["MacLennan, Matthew S."],"dc:date":["2018"],"dc:description":["Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) combines the superior separation efficiency of CE with the detection capability of MS to provide information-rich data on samples with complex matrices. CE-ESI-MS is applied to a range of complex mixtures to semi-quantify unknown components and find patterns among groups of samples. The first part of this thesis tells how the industrial generation of oil sands process-affected waters (OSPW) poses an environmental threat, and a review is given on the state-of-the-art of analytical chemistry in the semi-quantification of toxic naphthenic acid fraction compounds (NAFC) in OSPW. The chapter ends with a technical description of the CE-ESI-MS system which was utilized. CE-ESI-MS was demonstrated to produce effective analyses of a well-known complex mixture: human urine. CE-ESI-MS was used to quantify and “fingerprint” components in human urine via targeted and untargeted analyses of the sub-5 kDa urine metabolome of patients with prostate and/or bladder cancer. For targeted analysis, endogenous levels of sarcosine and 5 other metabolites were quantified in four patients and in a pooled healthy urine sample. An untargeted analysis of patient urine was also performed identifying over 400 distinct molecular features per patient. Next, a CE-ESI-MS method was developed for the analysis of a relatively unknown complex mixture: NAFCs in OSPW. A standard mixture of amine-derivatized naphthenic acids was analyzed in under 15 min, detecting NAFCs between m/z 250 and 800. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide in three different solvents. The optimum BGE composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. The optimized CE-ESI-MS method was then used to find patterns in NAFCs across porewater samples impacted by oil sands waste. CE-ESI-MS, Orbitrap MS, and a standard GC-FID method were used to characterize porewater samples. Differences in measured amounts of total petroleum hydrocarbon by GC-FID and NAFC by HRMS indicate that the two methods provide complementary information about dissolved organic species in water leachate samples. CE-ESI-MS also provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water."],"dc:format":["4102318","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/67116","http://circle.library.ubc.ca/bitstream/2429/67116/1/ubc_2018_november_maclennan_matthew.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Capillary electrophoresis-mass spectrometry and complementary approaches for semi-quantitative analysis of samples with complex matrices"],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:02:19Z"}