{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/6993"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/6993","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Automated decomposition of electromyographic signals recorded with surface electrode arrays","abstract":"This thesis presents results of various investigations which led to the development and validation of a new system for multi-channel surface electromyographic (EMG) recording for clinical examinations (McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED). To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with high selectivity, resolution and signal-to-noise ratios. To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system, McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly different locations on the skin; 2) the representation of MUAPs with their spatial distribution and temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a maximum-likelihood estimator. Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32 control subjects were “slow MUs” (v < 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the muscles of four patients with myopathic disorders were slow MUs.","abstract_html":"This thesis presents results of various investigations which led to the development and validation of a new system for multi-channel surface electromyographic (EMG) recording for clinical examinations (McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED). To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with high selectivity, resolution and signal-to-noise ratios. To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system, McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly different locations on the skin; 2) the representation of MUAPs with their spatial distribution and temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a maximum-likelihood estimator. Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32 control subjects were “slow MUs” (v &lt; 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the muscles of four patients with myopathic disorders were slow MUs.","abstract_has_math":false,"creators":["Chen, Yunquan"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-19T14:26:52Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/6993","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/6993","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/6993/1/ubc_1994-953241.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F6993","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chen, Yunquan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/6993","http://circle.library.ubc.ca/bitstream/2429/6993/1/ubc_1994-953241.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis presents results of various investigations which led to the development and validation of a new system for multi-channel surface electromyographic (EMG) recording for clinical examinations (McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED). To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with high selectivity, resolution and signal-to-noise ratios. To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system, McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly different locations on the skin; 2) the representation of MUAPs with their spatial distribution and temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a maximum-likelihood estimator. Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32 control subjects were “slow MUs” (v < 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the muscles of four patients with myopathic disorders were slow MUs."]},{"key":"dc:format","label":"Dc Format","values":["4506804","application/pdf"]},{"key":"dc:title","label":"Title","values":["Automated decomposition of electromyographic signals recorded with surface electrode arrays"]}]}],"canonical_facts":{"dc:creator":["Chen, Yunquan"],"dc:date":["1994"],"dc:description":["This thesis presents results of various investigations which led to the development and validation of a new system for multi-channel surface electromyographic (EMG) recording for clinical examinations (McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED). To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with high selectivity, resolution and signal-to-noise ratios. To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system, McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly different locations on the skin; 2) the representation of MUAPs with their spatial distribution and temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a maximum-likelihood estimator. Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32 control subjects were “slow MUs” (v < 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the muscles of four patients with myopathic disorders were slow MUs."],"dc:format":["4506804","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/6993","http://circle.library.ubc.ca/bitstream/2429/6993/1/ubc_1994-953241.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Automated decomposition of electromyographic signals recorded with surface electrode arrays"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:26:52Z"}