{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/69982"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/69982","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A Raman spectral characterization of thin-film carbon : the impact of source wavelength variation","abstract":"Raman spectroscopy is ubiquitous in the study of thin-film carbon. Often, the Raman spectrum of a thin-film carbon is characterized in terms of the location of two distinct peaks, a D-peak located around 1360 cm-¹ and a G-peak located about 1580 cm-¹. Many of the material properties of thin-film carbon have been related either to the ratio of the D-peak and G-peak amplitudes or to the ratio of the D-peak and G-peak integrated intensities. In this analysis, I aim to assess whether or not a relationship exists between these two distinct ratios. Through an examination of the Raman spectra associated with a number of representative carbon thin-films, it has been established that the amplitude ratio is indeed related to the corresponding integrated intensity ratio. The samples of thin-film carbon that are probed using Raman spectroscopy have been prepared through the use of plasma-enhanced chemical vapor deposition and rf and dc magnetron sputtering. The slope of this relationship is shown to be related to the source wavelength, larger source wavelengths corresponding to a smaller slope. The scatter about the resultant linear fit is also found to increase as the source wavelength is increased. Recommendation for further study are offered.","abstract_html":"Raman spectroscopy is ubiquitous in the study of thin-film carbon. Often, the Raman spectrum of a thin-film carbon is characterized in terms of the location of two distinct peaks, a D-peak located around 1360 cm-¹ and a G-peak located about 1580 cm-¹. Many of the material properties of thin-film carbon have been related either to the ratio of the D-peak and G-peak amplitudes or to the ratio of the D-peak and G-peak integrated intensities. In this analysis, I aim to assess whether or not a relationship exists between these two distinct ratios. Through an examination of the Raman spectra associated with a number of representative carbon thin-films, it has been established that the amplitude ratio is indeed related to the corresponding integrated intensity ratio. The samples of thin-film carbon that are probed using Raman spectroscopy have been prepared through the use of plasma-enhanced chemical vapor deposition and rf and dc magnetron sputtering. The slope of this relationship is shown to be related to the source wavelength, larger source wavelengths corresponding to a smaller slope. The scatter about the resultant linear fit is also found to increase as the source wavelength is increased. Recommendation for further study are offered.","abstract_has_math":false,"creators":["Ahsan, Md. Ashraf Ul"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T15:10:49Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/69982","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/69982","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/69982/4/ubc_2019_may_ahsan_ashraf.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F69982","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ahsan, Md. Ashraf Ul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/69982","http://circle.library.ubc.ca/bitstream/2429/69982/4/ubc_2019_may_ahsan_ashraf.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Raman spectroscopy is ubiquitous in the study of thin-film carbon. Often, the Raman spectrum of a thin-film carbon is characterized in terms of the location of two distinct peaks, a D-peak located around 1360 cm-¹ and a G-peak located about 1580 cm-¹. Many of the material properties of thin-film carbon have been related either to the ratio of the D-peak and G-peak amplitudes or to the ratio of the D-peak and G-peak integrated intensities. In this analysis, I aim to assess whether or not a relationship exists between these two distinct ratios. Through an examination of the Raman spectra associated with a number of representative carbon thin-films, it has been established that the amplitude ratio is indeed related to the corresponding integrated intensity ratio. The samples of thin-film carbon that are probed using Raman spectroscopy have been prepared through the use of plasma-enhanced chemical vapor deposition and rf and dc magnetron sputtering. The slope of this relationship is shown to be related to the source wavelength, larger source wavelengths corresponding to a smaller slope. The scatter about the resultant linear fit is also found to increase as the source wavelength is increased. Recommendation for further study are offered."]},{"key":"dc:format","label":"Dc Format","values":["17807893","application/pdf"]},{"key":"dc:title","label":"Title","values":["A Raman spectral characterization of thin-film carbon : the impact of source wavelength variation"]}]}],"canonical_facts":{"dc:creator":["Ahsan, Md. Ashraf Ul"],"dc:date":["2019"],"dc:description":["Raman spectroscopy is ubiquitous in the study of thin-film carbon. Often, the Raman spectrum of a thin-film carbon is characterized in terms of the location of two distinct peaks, a D-peak located around 1360 cm-¹ and a G-peak located about 1580 cm-¹. Many of the material properties of thin-film carbon have been related either to the ratio of the D-peak and G-peak amplitudes or to the ratio of the D-peak and G-peak integrated intensities. In this analysis, I aim to assess whether or not a relationship exists between these two distinct ratios. Through an examination of the Raman spectra associated with a number of representative carbon thin-films, it has been established that the amplitude ratio is indeed related to the corresponding integrated intensity ratio. The samples of thin-film carbon that are probed using Raman spectroscopy have been prepared through the use of plasma-enhanced chemical vapor deposition and rf and dc magnetron sputtering. The slope of this relationship is shown to be related to the source wavelength, larger source wavelengths corresponding to a smaller slope. The scatter about the resultant linear fit is also found to increase as the source wavelength is increased. Recommendation for further study are offered."],"dc:format":["17807893","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/69982","http://circle.library.ubc.ca/bitstream/2429/69982/4/ubc_2019_may_ahsan_ashraf.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["A Raman spectral characterization of thin-film carbon : the impact of source wavelength variation"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:10:49Z"}