{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/71999"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/71999","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Development of a fast methane sensor based on wavelength modulation spectroscopy for exhaust methane emission measurement","abstract":"Natural gas is an attractive alternative fuel with a lower price and carbon dioxide emission compared to liquid fossil fuels. Methane (CH₄) in natural gas, however, has a high global warming potential (GWP), thus the emission of unburnt CH₄ can offset the cleaner combustion of natural gas and should be carefully monitored in dual-fuel natural gas/diesel engines. To develop cleaner engines, a high-speed methane sensor in the exhaust gas stream is required to capture emissions during real-world, transient engine operation. While CH₄ measurements using Fourier-transform infrared (FTIR) spectroscopy in dual-fuel engines have been demonstrated, its speed is insufficient for cycle-resolved measurements. To this end, a fast, robust, and inexpensive CH₄ sensor based on wavelength modulation spectroscopy (WMS) was developed using a relatively inexpensive IR diode laser with a centre wavelength of 1651 nm. The WMS sensor was assessed using gas standards and validated against a flame ionization detector (FID). The 508 mm heated gas cell reliably detects CH₄ from 50 ppm to over 2% at a temporal resolution of over 200 Hz. The WMS sensor can resolve transient methane emission with a time delay and time constant of 0.55 s and 0.44 s respectively. When demonstrated on a heavy-duty dual-fuel research engine, the WMS sensor and FID agreed with a mean percentage difference of 4.2%. The field measurement capability of this portable sensor, which can continuously measure for seconds to hours, was demonstrated on dual-fuel marine engines of a coastal vessel. The GWP of dual-fuel engine exhaust heavily depends on operational profiles, and the fast WMS methane sensor will assist engineers and policy makers to characterize and reduce in-use CH₄ emissions.","abstract_html":"Natural gas is an attractive alternative fuel with a lower price and carbon dioxide emission compared to liquid fossil fuels. Methane (CH₄) in natural gas, however, has a high global warming potential (GWP), thus the emission of unburnt CH₄ can offset the cleaner combustion of natural gas and should be carefully monitored in dual-fuel natural gas/diesel engines. To develop cleaner engines, a high-speed methane sensor in the exhaust gas stream is required to capture emissions during real-world, transient engine operation. While CH₄ measurements using Fourier-transform infrared (FTIR) spectroscopy in dual-fuel engines have been demonstrated, its speed is insufficient for cycle-resolved measurements. To this end, a fast, robust, and inexpensive CH₄ sensor based on wavelength modulation spectroscopy (WMS) was developed using a relatively inexpensive IR diode laser with a centre wavelength of 1651 nm. The WMS sensor was assessed using gas standards and validated against a flame ionization detector (FID). The 508 mm heated gas cell reliably detects CH₄ from 50 ppm to over 2% at a temporal resolution of over 200 Hz. The WMS sensor can resolve transient methane emission with a time delay and time constant of 0.55 s and 0.44 s respectively. When demonstrated on a heavy-duty dual-fuel research engine, the WMS sensor and FID agreed with a mean percentage difference of 4.2%. The field measurement capability of this portable sensor, which can continuously measure for seconds to hours, was demonstrated on dual-fuel marine engines of a coastal vessel. The GWP of dual-fuel engine exhaust heavily depends on operational profiles, and the fast WMS methane sensor will assist engineers and policy makers to characterize and reduce in-use CH₄ emissions.","abstract_has_math":false,"creators":["Son, Donghyun (Jeff)"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T15:11:13Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/71999","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/71999","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/71999/4/ubc_2019_november_son_donghyun.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F71999","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Son, Donghyun (Jeff)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/71999","http://circle.library.ubc.ca/bitstream/2429/71999/4/ubc_2019_november_son_donghyun.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Natural gas is an attractive alternative fuel with a lower price and carbon dioxide emission compared to liquid fossil fuels. Methane (CH₄) in natural gas, however, has a high global warming potential (GWP), thus the emission of unburnt CH₄ can offset the cleaner combustion of natural gas and should be carefully monitored in dual-fuel natural gas/diesel engines. To develop cleaner engines, a high-speed methane sensor in the exhaust gas stream is required to capture emissions during real-world, transient engine operation. While CH₄ measurements using Fourier-transform infrared (FTIR) spectroscopy in dual-fuel engines have been demonstrated, its speed is insufficient for cycle-resolved measurements. To this end, a fast, robust, and inexpensive CH₄ sensor based on wavelength modulation spectroscopy (WMS) was developed using a relatively inexpensive IR diode laser with a centre wavelength of 1651 nm. The WMS sensor was assessed using gas standards and validated against a flame ionization detector (FID). The 508 mm heated gas cell reliably detects CH₄ from 50 ppm to over 2% at a temporal resolution of over 200 Hz. The WMS sensor can resolve transient methane emission with a time delay and time constant of 0.55 s and 0.44 s respectively. When demonstrated on a heavy-duty dual-fuel research engine, the WMS sensor and FID agreed with a mean percentage difference of 4.2%. The field measurement capability of this portable sensor, which can continuously measure for seconds to hours, was demonstrated on dual-fuel marine engines of a coastal vessel. The GWP of dual-fuel engine exhaust heavily depends on operational profiles, and the fast WMS methane sensor will assist engineers and policy makers to characterize and reduce in-use CH₄ emissions."]},{"key":"dc:format","label":"Dc Format","values":["15422036","application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a fast methane sensor based on wavelength modulation spectroscopy for exhaust methane emission measurement"]}]}],"canonical_facts":{"dc:creator":["Son, Donghyun (Jeff)"],"dc:date":["2019"],"dc:description":["Natural gas is an attractive alternative fuel with a lower price and carbon dioxide emission compared to liquid fossil fuels. Methane (CH₄) in natural gas, however, has a high global warming potential (GWP), thus the emission of unburnt CH₄ can offset the cleaner combustion of natural gas and should be carefully monitored in dual-fuel natural gas/diesel engines. To develop cleaner engines, a high-speed methane sensor in the exhaust gas stream is required to capture emissions during real-world, transient engine operation. While CH₄ measurements using Fourier-transform infrared (FTIR) spectroscopy in dual-fuel engines have been demonstrated, its speed is insufficient for cycle-resolved measurements. To this end, a fast, robust, and inexpensive CH₄ sensor based on wavelength modulation spectroscopy (WMS) was developed using a relatively inexpensive IR diode laser with a centre wavelength of 1651 nm. The WMS sensor was assessed using gas standards and validated against a flame ionization detector (FID). The 508 mm heated gas cell reliably detects CH₄ from 50 ppm to over 2% at a temporal resolution of over 200 Hz. The WMS sensor can resolve transient methane emission with a time delay and time constant of 0.55 s and 0.44 s respectively. When demonstrated on a heavy-duty dual-fuel research engine, the WMS sensor and FID agreed with a mean percentage difference of 4.2%. The field measurement capability of this portable sensor, which can continuously measure for seconds to hours, was demonstrated on dual-fuel marine engines of a coastal vessel. The GWP of dual-fuel engine exhaust heavily depends on operational profiles, and the fast WMS methane sensor will assist engineers and policy makers to characterize and reduce in-use CH₄ emissions."],"dc:format":["15422036","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/71999","http://circle.library.ubc.ca/bitstream/2429/71999/4/ubc_2019_november_son_donghyun.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Development of a fast methane sensor based on wavelength modulation spectroscopy for exhaust methane emission measurement"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:11:13Z"}