{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/73994"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/73994","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Capillary electrophoresis-mass spectrometry for the analysis of neurochemicals","abstract":"In order to quantify low concentrations of dopamine in complex biological matrices, a capillary electrophoresis-mass spectrometry pH stacking method was developed and optimized. The pH stacking method operates by concentrating the analyte on-capillary through manipulation of electrophoretic mobility in regions of different pH. This method allowed for a detection limit of 0.1 ng/mL, approximately 2 orders of magnitude lower than using a more traditional capillary zone electrophoresis (non-stacking) method. The stacking method was determined to be linear from 0.5-1000 ng/mL dopamine with accuracy values within 10% and precision values within 5% across the range. A CE compatible method for the extraction of dopamine from intracellular and extracellular cell culture components was also developed. This method was then applied to the analysis of dopamine in STHdh cells, a model for Huntington’s disease, showing a lower concentration of dopamine in disease cells compared to normal phenotype, consistent with current literature data on Huntington’s disease. In addition, steps were taken toward the development of a CE-MS method for the measurement of uridine diphosphate sugars in cerebrospinal fluid with advantages including short analysis time (<20 mins) and low sample consumption.","abstract_html":"In order to quantify low concentrations of dopamine in complex biological matrices, a capillary electrophoresis-mass spectrometry pH stacking method was developed and optimized. The pH stacking method operates by concentrating the analyte on-capillary through manipulation of electrophoretic mobility in regions of different pH. This method allowed for a detection limit of 0.1 ng/mL, approximately 2 orders of magnitude lower than using a more traditional capillary zone electrophoresis (non-stacking) method. The stacking method was determined to be linear from 0.5-1000 ng/mL dopamine with accuracy values within 10% and precision values within 5% across the range. A CE compatible method for the extraction of dopamine from intracellular and extracellular cell culture components was also developed. This method was then applied to the analysis of dopamine in STHdh cells, a model for Huntington’s disease, showing a lower concentration of dopamine in disease cells compared to normal phenotype, consistent with current literature data on Huntington’s disease. In addition, steps were taken toward the development of a CE-MS method for the measurement of uridine diphosphate sugars in cerebrospinal fluid with advantages including short analysis time (&lt;20 mins) and low sample consumption.","abstract_has_math":false,"creators":["Kowalczyk, Adam"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T15:11:29Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/73994","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/73994","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/73994/4/ubc_2020_may_kowalczyk_adam.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F73994","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kowalczyk, Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/73994","http://circle.library.ubc.ca/bitstream/2429/73994/4/ubc_2020_may_kowalczyk_adam.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In order to quantify low concentrations of dopamine in complex biological matrices, a capillary electrophoresis-mass spectrometry pH stacking method was developed and optimized. The pH stacking method operates by concentrating the analyte on-capillary through manipulation of electrophoretic mobility in regions of different pH. This method allowed for a detection limit of 0.1 ng/mL, approximately 2 orders of magnitude lower than using a more traditional capillary zone electrophoresis (non-stacking) method. The stacking method was determined to be linear from 0.5-1000 ng/mL dopamine with accuracy values within 10% and precision values within 5% across the range. A CE compatible method for the extraction of dopamine from intracellular and extracellular cell culture components was also developed. This method was then applied to the analysis of dopamine in STHdh cells, a model for Huntington’s disease, showing a lower concentration of dopamine in disease cells compared to normal phenotype, consistent with current literature data on Huntington’s disease. In addition, steps were taken toward the development of a CE-MS method for the measurement of uridine diphosphate sugars in cerebrospinal fluid with advantages including short analysis time (<20 mins) and low sample consumption."]},{"key":"dc:format","label":"Dc Format","values":["4415885","application/pdf"]},{"key":"dc:title","label":"Title","values":["Capillary electrophoresis-mass spectrometry for the analysis of neurochemicals"]}]}],"canonical_facts":{"dc:creator":["Kowalczyk, Adam"],"dc:date":["2020"],"dc:description":["In order to quantify low concentrations of dopamine in complex biological matrices, a capillary electrophoresis-mass spectrometry pH stacking method was developed and optimized. The pH stacking method operates by concentrating the analyte on-capillary through manipulation of electrophoretic mobility in regions of different pH. This method allowed for a detection limit of 0.1 ng/mL, approximately 2 orders of magnitude lower than using a more traditional capillary zone electrophoresis (non-stacking) method. The stacking method was determined to be linear from 0.5-1000 ng/mL dopamine with accuracy values within 10% and precision values within 5% across the range. A CE compatible method for the extraction of dopamine from intracellular and extracellular cell culture components was also developed. This method was then applied to the analysis of dopamine in STHdh cells, a model for Huntington’s disease, showing a lower concentration of dopamine in disease cells compared to normal phenotype, consistent with current literature data on Huntington’s disease. In addition, steps were taken toward the development of a CE-MS method for the measurement of uridine diphosphate sugars in cerebrospinal fluid with advantages including short analysis time (<20 mins) and low sample consumption."],"dc:format":["4415885","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/73994","http://circle.library.ubc.ca/bitstream/2429/73994/4/ubc_2020_may_kowalczyk_adam.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Capillary electrophoresis-mass spectrometry for the analysis of neurochemicals"],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:11:29Z"}