{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/75217"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/75217","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Investigation of solutions for universal input 208 v-480 v three-phase ac/dc power factor corrected converters with 400 v dc output","abstract":"A high-performance, three-phase power factor corrected (PFC) front-end converter with universal input (i.e. 208 V-480 V AC) and 400 V DC output voltage is desirable for applications including Electric Vehicle (EV) battery chargers and data centers. Products that operate with a universal input reduce development and manufacturing costs, in lieu of multiple products for different values of AC input voltages. Three-phase AC inputs reduce the cost of electric circuit cabling and a 400 V DC output is favorable as it reduces the stress on the back-end isolated DC/DC converter stage between the PFC converter and DC output. This dissertation focuses on the best practices and solutions for a universal three-phase AC input PFC converter with 400 V DC output. A detailed review of existing solutions is presented with their advantages and drawbacks noted. The conventional solution of three phase boost follows buck was prototyped and used as a benchmark against the proposed solutions. An adaptive intermediate bus voltage control method is proposed to maximize the efficiency in a three-phase six-switch boost-follows-buck converter. A prototype was developed and experimentally tested to confirm the expected efficiency improvement. In addition, a novel truly universal input (i.e. single-phase or three-phase) PFC with 400 V DC output is also proposed and implemented which can serve the dual purpose of single-phase and three-phase operation. It is shown by analysis and experiments that this solution is not only highly efficient for both single-phase and three-phase operation, but also the components sized for single-phase mode of operation are not oversized for three-phase. Finally, a novel universal input single-stage SEPIC based third harmonic injection three-phase AC/DC PFC is proposed. Control simplicity and single-stage operation are among the main features for this topology.","abstract_html":"A high-performance, three-phase power factor corrected (PFC) front-end converter with universal input (i.e. 208 V-480 V AC) and 400 V DC output voltage is desirable for applications including Electric Vehicle (EV) battery chargers and data centers. Products that operate with a universal input reduce development and manufacturing costs, in lieu of multiple products for different values of AC input voltages. Three-phase AC inputs reduce the cost of electric circuit cabling and a 400 V DC output is favorable as it reduces the stress on the back-end isolated DC/DC converter stage between the PFC converter and DC output. This dissertation focuses on the best practices and solutions for a universal three-phase AC input PFC converter with 400 V DC output. A detailed review of existing solutions is presented with their advantages and drawbacks noted. The conventional solution of three phase boost follows buck was prototyped and used as a benchmark against the proposed solutions. An adaptive intermediate bus voltage control method is proposed to maximize the efficiency in a three-phase six-switch boost-follows-buck converter. A prototype was developed and experimentally tested to confirm the expected efficiency improvement. In addition, a novel truly universal input (i.e. single-phase or three-phase) PFC with 400 V DC output is also proposed and implemented which can serve the dual purpose of single-phase and three-phase operation. It is shown by analysis and experiments that this solution is not only highly efficient for both single-phase and three-phase operation, but also the components sized for single-phase mode of operation are not oversized for three-phase. Finally, a novel universal input single-stage SEPIC based third harmonic injection three-phase AC/DC PFC is proposed. Control simplicity and single-stage operation are among the main features for this topology.","abstract_has_math":false,"creators":["Hafezinasab, Hamidreza"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T15:11:47Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/75217","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/75217","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/75217/1/ubc_2020_september_hafezinasab_hamidreza.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F75217","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hafezinasab, Hamidreza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/75217","http://circle.library.ubc.ca/bitstream/2429/75217/1/ubc_2020_september_hafezinasab_hamidreza.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A high-performance, three-phase power factor corrected (PFC) front-end converter with universal input (i.e. 208 V-480 V AC) and 400 V DC output voltage is desirable for applications including Electric Vehicle (EV) battery chargers and data centers. Products that operate with a universal input reduce development and manufacturing costs, in lieu of multiple products for different values of AC input voltages. Three-phase AC inputs reduce the cost of electric circuit cabling and a 400 V DC output is favorable as it reduces the stress on the back-end isolated DC/DC converter stage between the PFC converter and DC output. This dissertation focuses on the best practices and solutions for a universal three-phase AC input PFC converter with 400 V DC output. A detailed review of existing solutions is presented with their advantages and drawbacks noted. The conventional solution of three phase boost follows buck was prototyped and used as a benchmark against the proposed solutions. An adaptive intermediate bus voltage control method is proposed to maximize the efficiency in a three-phase six-switch boost-follows-buck converter. A prototype was developed and experimentally tested to confirm the expected efficiency improvement. In addition, a novel truly universal input (i.e. single-phase or three-phase) PFC with 400 V DC output is also proposed and implemented which can serve the dual purpose of single-phase and three-phase operation. It is shown by analysis and experiments that this solution is not only highly efficient for both single-phase and three-phase operation, but also the components sized for single-phase mode of operation are not oversized for three-phase. Finally, a novel universal input single-stage SEPIC based third harmonic injection three-phase AC/DC PFC is proposed. Control simplicity and single-stage operation are among the main features for this topology."]},{"key":"dc:format","label":"Dc Format","values":["5948868","application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of solutions for universal input 208 v-480 v three-phase ac/dc power factor corrected converters with 400 v dc output"]}]}],"canonical_facts":{"dc:creator":["Hafezinasab, Hamidreza"],"dc:date":["2020"],"dc:description":["A high-performance, three-phase power factor corrected (PFC) front-end converter with universal input (i.e. 208 V-480 V AC) and 400 V DC output voltage is desirable for applications including Electric Vehicle (EV) battery chargers and data centers. Products that operate with a universal input reduce development and manufacturing costs, in lieu of multiple products for different values of AC input voltages. Three-phase AC inputs reduce the cost of electric circuit cabling and a 400 V DC output is favorable as it reduces the stress on the back-end isolated DC/DC converter stage between the PFC converter and DC output. This dissertation focuses on the best practices and solutions for a universal three-phase AC input PFC converter with 400 V DC output. A detailed review of existing solutions is presented with their advantages and drawbacks noted. The conventional solution of three phase boost follows buck was prototyped and used as a benchmark against the proposed solutions. An adaptive intermediate bus voltage control method is proposed to maximize the efficiency in a three-phase six-switch boost-follows-buck converter. A prototype was developed and experimentally tested to confirm the expected efficiency improvement. In addition, a novel truly universal input (i.e. single-phase or three-phase) PFC with 400 V DC output is also proposed and implemented which can serve the dual purpose of single-phase and three-phase operation. It is shown by analysis and experiments that this solution is not only highly efficient for both single-phase and three-phase operation, but also the components sized for single-phase mode of operation are not oversized for three-phase. Finally, a novel universal input single-stage SEPIC based third harmonic injection three-phase AC/DC PFC is proposed. Control simplicity and single-stage operation are among the main features for this topology."],"dc:format":["5948868","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/75217","http://circle.library.ubc.ca/bitstream/2429/75217/1/ubc_2020_september_hafezinasab_hamidreza.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Investigation of solutions for universal input 208 v-480 v three-phase ac/dc power factor corrected converters with 400 v dc output"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:11:47Z"}